10.07.2015 Views

CMH Floor Plans (PDF)

CMH Floor Plans (PDF)

CMH Floor Plans (PDF)

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C:\Users\shara.castillo\Desktop\revit local\80642 CENTRAL D&T.rvtAM30' - 0"01101NOTES:1. THESE NOTES APPLY TO ENLARGED PLANS A-F.2. DIMENSIONS LOCATING PARTITIONS ARE REFERENCED TOEXTERIOR FACE OF GYPSUM BOARD OR CMU. DIMENSIONSLOCATING INTERIOR WINDOWS AND DOORS ARE REFERENCED TOINSIDE FACE OF FRAME.3. DIMENSIONS NOTED AS “CLEAR” ARE TO FACE OF FINISH LAYER.4. REFER TO DETAILS ON SHEETS A8.01.3, A8.08.1, AND A8.08.2 FORWALL CONDITIONS AT THE INTERFACE OF EXTERIOR WALLS.5. REFER TO DRAWING A8.01.1 FOR PARTITION TYPES,CONFIGURATIONS, AND DESIGNATIONS.Architecture / Planning / Interior DesignPortland Seattle Los Angeles Washington DC515 South Flower Street, Suite 3700Los Angeles, California 90071(PH) 213 617 1901(FAX) 213 617 0047D D.5 E.5 F.5 G.5 H.5 J.514' - 2" 30' - 10" 30' - 0" 30' - 0" 30' - 0" 30' - 0"1 16. REFER TO DRAWINGS A8.01.2, A8.01.3, A8.01.4 FOR SPECIALCONDITIONS IN PARTITIONS SUCH AS FIRE STOP, SMOKE SEAL,TERMINATION AT FLOORS, INTERFACE WITH STRUCTURALMEMBERS, AND BUILT-IN ITEMS.7. REFER TO A8.01.2 FOR REINFORCEMENT DETAILS FOR VARIOUSWALL MOUNTED EQUIPMENT.8. REFER TO A8.06.1 AND A8.06.2 FOR ROOM CLEARANCES ANDMOUNTING HEIGHTS OF FIXTURES IN SINGLE OCCUPANCY TOILETROOMS.9. REFER TO A8.07.3 FOR DETAILS AT WALL PROTECTION.10. REFER TO A8.08.1 AND A8.08.2 FOR INTERFACE OF INTERIORPARTITIONS WITH EXTERIOR WINDOWS, INCLUDING SILL, JAMB,AND HEAD CONDITIONS.AndersonMikos Architects ltd.One Parkview Plaza17 W 110 22nd St. Suite 200Oakbrook Terrace, IL 60181Tel. 630 - 573 - 5149Fax. 630 - 573 - 517630' - 7 1/2"11. DASHED LINE AT CASEWORK REPRESENTS UPPER CABINETS.30' - 0"30' - 10"22' - 4" 31' - 10"30' - 0"30' - 0"25' - 0"30' - 0"30' - 0"30' - 0"5.2ABC5.92 23 34 47 78 830' - 0"9 930' - 10"30' - 10"10 105612. ROOM IDENTIFICATION:OFFICE01101ROOM NAMEROOM NUMBER13. DOOR IDENTIFICATION:6" TYPICALUPPERSDOOR NUMBER(RELATES TOROOM NUMBER)14. SEE EQUIPMENT PLANS (EQ SERIES) AND EQUIPMENT LISTS FORLOCATION AND PRODUCT INFORMATION FOR ALL WALL MOUNTEDEQUIPMENT AND ASSOCIATED BACKING REQUIREMENTS.15. EQUIPMENT ITEMS THAT ARE OWNER FURNISHED OWNERINSTALLED (OFOI) OR OWNER FURNISHED VENDOR INSTALLED(OFVI) MAY REQUIRE ADDITIONAL BRACING, BLOCKING, METALBACKING OR HEAVIER GAGE WALL FRAMING. COORDINATE WITHOWNER/VENDOR EQUIPMENT SHOP DRAWINGS.16. VERIFY FINAL LOCATION OF ALL WALL MOUNTED EQUIPMENT WITHCLIENT ON SITE.17. REFER TO ROOM FINISH SCHEDULE FOR FINISH MATERIALS ANDRELATED FINISH MATERIAL CODES.18. FOR CUBICLE CURTAIN / I.V. TRACK LOCATIONS, SEE RCP(A9 SERIES) DRAWINGS.19. REFER TO A8 SERIES DRAWINGS FOR SUPPORT DETAILS OFCEILING MOUNTED EQUIPMENT.20. REFER TO INTERIOR WINDOW SCHEDULE, A8.80 SERIES, FORDETAILS AT WALL OPENINGS FOR INTERIOR WINDOWS, AND A8.02.3FOR INTERIOR FIRE SHUTTERS.21. REFER TO A8 SERIES FOR FLOOR TRANSITION DETAILS AND WALLBASE DETAILS THAT MEET COC CRITERIA LISTED IN CHAPTER 18-11AND ICC A117.1-2003 CODE SECTIONS 3.302, 3.303, 4.403.22. REFER TO A8 SERIES FOR PROTRUDING DETAILS THAT MEET THECOC CRITERIA LISTED IN CHAPTER 18-11 AND ICC A117.1- 2003 CODESECTION 3.307.23. ALL CORRIDORS WITH PATIENT TREATMENT AND/OR PATIENTSLEEPING SHALL BE A MINIMUM OF 8'-0" CLEAR WIDE.STRUCTURAL ENGINEERMAGNUSSON KLEMENCIC ASSOCIATES1301 FIFTH AVENUE, SUITE 3200SEATTLE, WA 91801M/E/P/FP ENGINEERAFFILIATED ENGINEERS INC.P.O. BOX 44991MADISON, WI 53744CIVIL ENGINEERV3 COMPANIES OF ILLINOIS LTD.7325 JANES AVENUEWOODRIDGE, IL 60517LANDSCAPE ARCHITECTCYLA DESIGN ASSOCIATES, INC.412 MADISON STREETOAK PARK, IL 60302Rev. Date Description03/03/2008 Doc Issue #5 - Bid Package #21 05/01/2008 Doc Issue #7 - Bid Package #3A2 09/17/2008 Doc Issue #11, Bid Pkg 4 & 53 12/09/2008 Doc Issue #14, Bid Pkg 6 / 7 A4 01/30/2009 Doc Issue #16, Bid Pkg 6/75 02/20/2009 Document Issuance #176 05/06/2009 Document Issuance #197 06/18/2009 Document Issuance #208 08/06/2009 Document Issuance #219 09/03/2009 Document Issuance #2210 11/19/2009 Document Issuance #24ANN & ROBERTH. LURIECHILDREN'S HOSPITAL OF CHICAGO225 E. Chicago AvenueChicago, IL 60611Drawing TitleOVERALL FLOOR PLAN -LEVEL 641' - 10" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 10"ABCDE F GH J K1 Overall Plan - Level 6A2.06SCALE: 1/16" = 1'-0"LEGEND:11/17/2009 10:03:14FVCFECFVECCGWP-6?A?.?1A101SIMFIRE VALVE CABINETFIRE EXTINGUISHER CABINETFIRE VALVE/EXTINGUISHER CABINETCORNER GUARDSWALL PROTECTION/CRASH RAILELEVATION TAGENLARGED PLANSEE ELECTRICAL DRAWINGSFOR FLOOR SERVICE DEVICE.A DB EC FKEY PLANDate:11/09/2009Job No.:L80642Drawn By: ZGFChecked By: ZGFDrawing No.A2.0610

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!