CC Power Plant Details & Description:Heat Recovery Steam Genera<strong>to</strong>r The gas turbine exhausts in<strong>to</strong> a triple pressure, vertical gas flow, heatrecovery steam genera<strong>to</strong>r manufactured by CMI. There is no exhaust gas bypass facility but the steam turbine can bebypassed <strong>to</strong> the condenser for short periods during start up, thus simplecycle operation is not possible.Steam Conditions:tn/hrTemp °C Pressure Bar FlowHP 566.7 124.51 272.5IP 566.7 26.10 319.0LP 277.2 4.60 337.05