11.07.2015 Views

Amperometric Hydrogen micro-sensor - AMT Analysenmesstechnik ...

Amperometric Hydrogen micro-sensor - AMT Analysenmesstechnik ...

Amperometric Hydrogen micro-sensor - AMT Analysenmesstechnik ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

General informations about the amperometric hydrogen <strong>micro</strong>-<strong>sensor</strong>2________________________________________________________________________________________________The advantages of the <strong>micro</strong>-<strong>sensor</strong> technologyFor manufacturing the amperometric H 2 <strong>sensor</strong> a special geometric design has been choosen to builta real <strong>micro</strong>-<strong>sensor</strong>. Electrode diameters below 25 µm, a very thin special membrane with smalldiameters, extremly short diffusion distances for the hydrogen to the working electrode and anegligible analyte consumption at the electrodes leading finally to response times (t 90% ) of less than 2seconds. The analyte consumption effects are negligible too, so that streaming of the <strong>sensor</strong>membrane and stirring is not necessary. Besides, the dimensions of the sensitive tips within a rangeof some <strong>micro</strong>meters allow insitu measurements without destroying equilibriums, concentrationgradients and geometrical structures. This is very important, if measurements in muddy sedimentsare required.Technical data for all H 2 -<strong>micro</strong>-<strong>sensor</strong> heads independent from the <strong>sensor</strong>design *) measuring principle: amperometric membrane covered <strong>micro</strong><strong>sensor</strong> 3 <strong>sensor</strong> electrodes exchangeable <strong>sensor</strong> head necessary time for the first polarization: approx. 15-30 minutes streaming of the membrane or stirring is not necessary, low analyte consumption suitable for the determination of concentration gradients with high local resolution measuring ranges: 0,0002....3 mg/l H 2others on request accuracy of the <strong>sensor</strong>:: better than 2% of the measuring value temperature range: 0°C to 30°C response times: t 90% : below 2 seconds average life time: approximately 6-10 months, may be influenced by the samples matrix pressure stability: laboratory <strong>sensor</strong> orshallow water version for pressures of up to 10 bar or housing: all housings made of titanium*) Changes for technical improvement are reserved.________________________________________________________________________________________________<strong>AMT</strong> <strong>Analysenmesstechnik</strong> GmbH 2001

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!