11.07.2015 Views

Twenkaship Marine Cables - TKD-KABEL | Продукция

Twenkaship Marine Cables - TKD-KABEL | Продукция

Twenkaship Marine Cables - TKD-KABEL | Продукция

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Halogen-free power cables<strong>Twenkaship</strong>-O 6/10 kV - 8.7/15 kV, one coreSingle core medium voltage cables designed for electric power transport between theengine room generator and electrical machines. Higher voltages available on request.PowerCopperbraidingConstruction:conductor: circular conductor of stranded plain annealed high-conductive copper (class-2)conductor screen: semi-conductive polymer layerinsulation: high quality cross-linked polyethylene (XLPE)insulation screen: semi-conductive polymer layer, covered by conductive swelling tapebraiding: tinned copper wiresouter sheath: red halogen-free, flame-retardant compound, SHF1marking: TKF-(type)-../.. kV-CS 85-mbzh-TWENKASHIP-O HALOGEN FREETechnical information:Rated voltage: 6/10 kV or 8.7/15 kVMin. Temp.: -5 °C during installation-40 °C fixed installedStandards: IEC 60092-350/-351/-359,IEC 60228,IEC 60354, IEC 60376IEC 60332-1,IEC 60332-3 –22AF,IEC 60754-1, IEC 61034-2For detailed technical specificationssee page 216/10 kV 8.7/15 kVno.cores x approx. overall approx. weight approx. overall approx. weightsq. mm diameter mm kg/km diameter mm kg/km1x16 20 600 22 7002x25 21 700 23 8001x35 22 800 24 9001x50 23 900 26 10001x70 25 1100 28 13001x95 27 1500 29 16001x120 28 1700 31 19001x150 30 2000 32 22001x185 32 2400 34 26001x240 34 3100 37 33001x300 37 3700 39 39001x400 41 4700 43 4800<strong>Twenkaship</strong>-O 6/10 kV - 8.7/15 kV, three coreThree core medium voltage cables designed for electric power transport between theengine room generator and electrical machines. Higher voltages available on request.PowerCopperbraidingTechnical information:Rated voltage: 6/10 kV or 8.7/15 kVMin. Temp.: -5 °C during installation-40 °C fixed installedStandards: IEC 60092-350/-351/-359,IEC 60228,IEC 60354, IEC 60376IEC 60332-1,IEC 60332-3 –22AF,IEC 60754-1, IEC 61034-2For detailed technical specificationssee page 21Construction:conductors: circular conductors of stranded plain annealed high-conductive copper (class-2)conductor screen: semi-conductive polymer layerinsulation: high quality cross-linked polyethylene (XLPE)insulation screen: semi-conductive polymer layer, covered by conductive swelling tapecable core: 3 cores filled up with filling material, earthing with copper tape each coreinner sheath: halogen-free, flame-retardant compoundbraiding: tinned copper wiresouter sheath: red halogen-free, flame-retardant compound, SHF1marking: TKF-(type)-../.. kV-CS 85-mbzh-TWENKASHIP-O HALOGEN FREE6/10 kV 8.7/15 kVno.cores x approx. overall approx. weight approx. overall approx. weightsq. mm diameter mm kg/km diameter mm kg/km3x16 45 2800 50 33003x25 47 3200 52 38003x35 50 3800 55 44003x50 52 4300 58 50003x70 57 5300 62 60003x95 61 6500 66 72003x120 64 7500 70 82003x150 68 8700 73 95003x185 72 10200 77 110003x240 78 12500 83 1340012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!