11.07.2015 Views

Amesti Range - Jetmaster

Amesti Range - Jetmaster

Amesti Range - Jetmaster

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSTALLATION INSTRUCTIONSCowl(stainless steel)Funnel(stainless steel)THE FLUES ARE THE MOST IMPORTANT COMPONENTS REGARDING THE FIREPLACESAFETY. THEY MUST BE INSTALLED ACCORDING TO THE INSTRUCTIONS AND KEPTAWAY FROM ANY FLAMMABLE MATERIALS.ADDITIONALLY, LEGAL NORMS AND LOCAL REGULATIONS MUT BE RESPECTED.Be environmentally friendly - avoid moist woodOuter Flue (zinc-alum)It covers the main flue from theceiling to the cowl. Mineral wool isinserted between the main flue andthe outer flue for insulation.Flashing(zinc-alum)Mineral WoolIs located between the maincanyonand the double canyonDistance to CombustibleMaterialAny flammable material must be aminimum distance of 15 cm. fromthe outer flueCeiling plate(stainless steel)Main Flue (stainless steel)It extends from the top of thefireplace to the cowl.Protection (refer to table)If your wall is wooden and you wantto put the fireplace close to the wall,place a metal or other nonflammable material plate on thewall, leaving space behind it for aircirculation.Metal BaseThis must be used if the floor iswooden, or is covered with carpetor plastic.1 Choose the location for the fireplace. Werecommend it to be positioned in the center ofthe room to be heated. If the wall is made offlammable material, you must apply the minimumdistances shown in the graphic and table. If youwant to position the fireplace close to the wall, youneed to protect it with a metal or non-flammableplate, 10 cm wider and 30 cm higher than thefireplace itself and separated from the wall by 3cm in order to allow free air circulation. If the flooris wooden, plastic, or covered with carpet or anyother flammable material, you must use a protectivemetal or non-flammable material base underthe fireplace.Fill the space between the main and outerflue pipes with the mineral wool supplied.The flue pipe should be as straight and verticalas possible. If required, you can use up to two 45ºbends. The vertical path should be twice as long asthe horizontal. All bends should be after the first lengthof flue and before the outer flue commences. Toensure optimal performance, the length of the mainflue should be more than 4 meters long and less than11 meters. Do not place any turnbuckles or regulatorson the main flue, since they can alter the fireplace’sperformance.cmcon protecciónsin protecciónA X Y14287 520 15Locate the center of the main flue in theceiling and drill a hole through the ceiling androof. If the roof is made of wood, the bore shouldhave a 55 cm diameter. In the attic section, placethe outer flue concentric to the main flue. Noflammable material should be within a 15 cmrange of the outer flue. The outer flue shouldrest on the ceiling plate.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!