11.07.2015 Views

Microplate Product Guide - Whatman

Microplate Product Guide - Whatman

Microplate Product Guide - Whatman

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Drug DiscoveryPhase SeparationUNIFILTERSample PrepUNIFILTERProtein PrecipitationUNIFILTERThe <strong>Whatman</strong> Protein Precipitation UNIFILTERis optimized for removing acetonitrileprecipitatedproteins from plasma orserum samples. Made with 2 mL, 96 well,rigid glass filled polypropylene, the<strong>Whatman</strong> Protein Precipitation UNIFILTER isboth robust and chemically resistant.The plates contain specially formulateddual membranes with two distinct layers.The top layer acts as a prefilter to removecoarse particulates. The bottom layer isoleophobic for retaining the well contentswithout dripping. This provides a final filterfor removing fine particulate matter whenvacuum or centrifugation is applied. Nowavailable in two models: Fast Flow (7720-7236) and Standard (7720-7235).Reference Literature:• Application Note, <strong>Whatman</strong> Protein PrecipitationUNIFILTER Fast Flow, #51657• Download at www.whatman.comThe <strong>Whatman</strong> Phase Separation Plate allowsfor a quick separation of halogenatedsolvents from an aqueous phase,with no carryover and no closemanual contact. The plateconsists of a 2 mL, 96 well,rigid glass filled polypropylenebody. It has long drip directorsto ensure accurate dispensingof the filtrate. <strong>Whatman</strong> 1PSmedia is sealed into each well.<strong>Whatman</strong> 1PS is a silicone-treated mediumwhich remains impervious to aqueoussolvents but allows the unimpeded passageof organic solvents. Provided that the solventlayer is in contact with the 1PS, the organicsolvent layer will drain under gravity until theaqueous interface is reached, when flow willstop automatically. If subsequent harvestingof the aqueous layer is required, a vacuumcan then be applied to remove this layer.ORDERING INFORMATIONBecause most HPLC autosamplers can nowaccommodate 96 well plates, it makesmore sense to prepare samplesusing 96 well filterplatesinstead of 96 syringe filters.The Sample Prep UNIFILTERincorporates a 0.45 µmPVDF membrane and issuitable for automated androbotic handling. The UNIFILTERis matched to its own UNIPLATEcollection plate, which is available inboth inert polypropylene and chemicallyresistant Multi-Chem material. The collectionplate can be sealed with pierceable capmatsor heat sealed. The samples can be filteredeither by centrifugation or vacuum.Catalog Well Well Plate Filter Well Quantity/Number Format Volume Material Media Bottom CasePROTEIN PRECIPITATION UNIFILTER7720-7235 96 2 mL Glass Polypropylene Standard — 17720-7236 96 2 mL Glass Polypropylene Fast Flow — 57701-5750* 96 750 µL Natural Polypropylene — Round Bottom 257701-5200* 96 2 mL Natural Polypropylene — Round Bottom 25PHASE SEPARATION UNIFILTER7720-7229-01 96 2 mL Glass Filled Polypropylene 1PS — 17701-5750* 96 750 µL Natural Polypropylene — Round Bottom 257701-5200* 96 2 mL Natural Polypropylene — Round Bottom 25SAMPLE PREP UNIFILTER7700-7206 96 2 mL Glass Filled Polypropylene 0.45 µm — 25HydrophilicPVDF7701-5200* 96 2 mL Polypropylene — Round Bottom 257701-6200* 96 2 mL Multi-Chem — Round Bottom 107701-5750* 96 750 µL Polypropylene — Round Bottom 257701-6750* 96 750 µL Multi-Chem — Round Bottom 107704-0104 96 — Silicone capmats for — — 502 mL microplates7704-0105 96 — Silicone capmats for — — 50750 µL microplates7704-0002 — — Aluminum foil heat seals — — 100* Collection Plates8 <strong>Microplate</strong> <strong>Product</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!