11.07.2015 Views

Residual current circuit breaker with integral overcurrent ... - ETI

Residual current circuit breaker with integral overcurrent ... - ETI

Residual current circuit breaker with integral overcurrent ... - ETI

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Residual</strong> <strong>current</strong> <strong>circuit</strong> <strong>breaker</strong>s <strong>with</strong> <strong>integral</strong> over<strong>current</strong> protectionKZS-2M I Δn= 10 mAl nType APackaging[A]6Code No. B002173211Code No. C002173231[kos]1/5410 002173212 002173232 1/5413 002173213 002173233 1/5416 002173214 002173234 1/54ASTI<strong>Residual</strong> <strong>current</strong> <strong>circuit</strong> <strong>breaker</strong> <strong>with</strong> <strong>integral</strong> over<strong>current</strong> protection KZS-2M 2pRated short-<strong>circuit</strong> capacity Rated <strong>current</strong> Tripping characteristic Rated residual <strong>current</strong>10 kA 6 - 25 A B, C 0,03 AKZS-2M 2p I Δn= 30 mAl n[A]PackagingCode No. B Code No. C [pcs]6 002172501 002172521 1/5410 002172502 002172522 1/5413 002172503 002172523 1/5415 002172504 002172524 1/5416 002172505 002172525 1/5420 002172506 002172526 1/5425 002172507 002172527 1/54New!<strong>Residual</strong> <strong>current</strong> <strong>circuit</strong> <strong>breaker</strong> <strong>with</strong> <strong>integral</strong> over<strong>current</strong> protection KZS-4M 3pRated short-<strong>circuit</strong> capacity Rated <strong>current</strong> Tripping characteristic Rated residual <strong>current</strong>10 kA 6 - 32 A B, C 0,03 AKZS-4M 3p I Δn= 30 mAl n[A]Type A Type AC Weight Packagingšifra B Code No. C Code No. B Code No. C [g] [pcs]6 002174701 002174721 002174801 002174821 478 1/2710 002174702 002174722 002174802 002174822 478 1/2713 002174703 002174723 002174803 002174823 478 1/2716 002174704 002174724 002174804 002174824 478 1/2720 002174705 002174725 002174805 002174825 478 1/2725 002174706 002174726 002174806 002174826 478 1/2732 002174707 002174727 002174807 002174827 478 1/27<strong>Residual</strong> <strong>current</strong> <strong>circuit</strong> <strong>breaker</strong> <strong>with</strong> <strong>integral</strong> over<strong>current</strong> protection KZS-4M 3p+NRated short-<strong>circuit</strong> capacity Rated <strong>current</strong> Tripping characteristic Rated residual <strong>current</strong>6 kA 6 - 32 A B, C 0,03 AKZS-4M 3p+N I Δn= 30 mAl n[A]Type A Type AC Weight PackagingCode No. B Code No. C Code No. B Code No. C [g] [pcs]6 002174901 002174921 002174001 002174021 478 1/2710 002174902 002174922 002174002 002174022 478 1/2713 002174903 002174923 002174003 002174023 478 1/2716 002174904 002174924 002174004 002174024 478 1/2720 002174905 002174925 002174005 002174025 478 1/2725 002174906 002174926 002174006 002174026 478 1/2732 002174907 002174927 002174007 002174027 478 1/27Technical data on page 341,34233

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!