11.07.2015 Views

RoofToP

RoofToP

RoofToP

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RED DOT UNITSRED DOT UNITSON ROAD/OFF ROADHEATER-A/CR-9777 RoofTopHeater/Air Conditioner UnitCONSTRUCTION • MINING •AGRICULTURERed Dot has used the latest in design techniques to producea rugged unit, which combines Euro styling with heavy dutycomponents that will withstand the roughest of applications. The R-9777Heater/Air conditioner is the first in our industry to employ engineered resintechnology. This Euro styling and design sets this unit far beyond the competition inappearance, durability and performance. Through Red Dots proven performance tests the R-9777 has exceeded our expectations.30"760mm7.9"200mm37"940mm1⁄ 2" Diameter13mm(Typical)Component Selection and Performance• High Performance Blower• Heavy Duty Tube and Fin Evaporator• High Capacity Spring Loaded Receiver Drier• Multi flow Condenser• A Single High Performance Durable Condenser FanDesign and Styling• Unique Low Profile Housing• “Built to Survive” Engineered Resin Housing• Positive Pressure Design• Optional Outside Air Pressurization• Easy to Service ComponentsPlenum• Contoured Design• Four Multi-Direction Louvers• Easy to Operate Switches and Controls• Recirculation Air FiltrationPerformance• 45,000 BTUs Heating• 25,000 BTUs Cooling• 355 CFM Air FlowR-9777 SPECIFICATIONSBTU’sHeating – 45,000 BTU/Hr @ 100°F (13.2 kW @ 37.8°C) air temp. riseCooling – 25,000 BTU/Hr with 36°F (7.3 kW with 2.2°C) refrigerant temp. and 80°F (26.7°C) wet bulb entering airAir Flow 355 CFM (580 m3/h)WeightMotorsCurrentDraw65 lbs.Evaporator – One 12 VDC, three speed (24 VDC available)Condenser – One 12 VDC low profile (24 VDC available)38.2 amps @ 13.6 VDC (includes 4 amps for A/C clutch)19.1 amps @ 27.2 VDC (includes 2 amps for A/C clutch)R-9777 SYSTEM ORDERING GUIDER12/R-134aNOTESUnits R-9777-0P Heater A/C 12VDCR-9777-0-24PHeater A/C 24VDCR-9777-1PA/C Only 12VDCR-9777-1-24PA/C Only 24VDCCONDENSER Contained in the R-9777INSTALLATION KIT 78R1805 Refrigerant hose, fittings and hardware.CompressorSee 75 Series Compressor sectionR12 Service Valves 75R5611 & 75R5618 Required with CCI and TECUMSEH applications.R134A Charge Fitting 75R5681 & 75R5688 Required with CCI and TECUMSEH applications.CLUTCH TECUMSEH/CCISee 75 Series Clutch sectionCOMPRESSOR MOUNT KIT See Compressor Mount Applications sectionOPTIONS Remote Mount Filters ** 78R5100 (Horizontal)78R5110 (Vertical)Replacement Filters 78R5210 (Remote Mount)Replacement Gasket KitRD-3-10210-0PIn-Line Booster Pressurizers * 73R9202 (12 VDC) For use with Remote Mount Filters73R9204 (24 VDC)Replacement Receiver Drier74R2546, 74R2590* Booster Pressurizer Can Only Be Used With Remote Mount Filters** Must be used with In-line Booster PressurizerHEATER-A/CMountingHoleLocations1⁄2" Radius13mm(Typical)5 1 ⁄8"130mm20 1 ⁄2"520mm7 3 ⁄4"195mm16 3 ⁄4"425mm4 1 ⁄2"125mmPlenumIncluded with kit= Limited to stock on handPAGE 46PAGE 47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!