Pads and AdaptersHeartStart Adult AEDDefibrillator PadsItem # DP2/DP6HeartStart Adult AED Defibrillator Pads(DP2 and DP6), recommended for patients8 years and older, or above 55 pounds (25kg),are optimized for use with Philips<strong>FR2</strong>-series defibrillators. Constructed ofa thin flexible conductor sandwichedbetween a protective polymer backing anda hydro-gel adhesive, these pads withstandthe rigors of CPR and harsh conditions.Soft, flexible and oval-shaped, HeartStartAdult AED Pads conform to body contoursfor ample surface contact and adhesion.For smooth handoff to advanced life support(ALS) personnel, the pads connector iscompatible with the hands-free cable ofHeartStart manual defibrillators which haveadvanced capabilities. Once attached, thesemultifunction electrode pads can provideECG monitoring, external pacing, andsynchronized cardioversion, in addition todefibrillation.<strong>FR2</strong> Infant/Child Reduced-EnergyDefibrillator PadsItem # M3870AHeartStart <strong>FR2</strong> Infant/Child DefibrillatorPads (M3870A) are for treating infants andchildren under 8 years of age or 55 poundswith an <strong>FR2</strong>-series defibrillator.These special infant/child pads containelectronics that attenuate, or reduce, theenergy of the defibrillator’s shock from 150to 50 Joules, a more appropriate dosage ofSMART Biphasic therapy for infants andsmall children. 1 And the <strong>FR2</strong>-seriesdefibrillator can evaluate children’s heartrhythms with outstanding accuracy. 2The pads’ design was carefully thought outto ensure that, even for the mostinexperienced user under the moststressful circumstances, it is instantlyobvious that these padsare for children and infantsonly.This helps ensurethat the correct pads arechosen when you need tobe prepared to treat bothadults and children.Thepackaging, graphics, and pinkteddy bear-shaped connectorclearly communicatepediatric use.HeartStart AdaptersHeartStart Adult AED Defibrillator Pads may also be used with defibrillators from other manufacturers, using PhilipsHeartStart Adapters, whether defibrillators are biphasic or monophasic, manual or automated.The adapters allow ALScaregivers to connect the pads to their manual defibrillator.Adapters cannot be used with <strong>FR2</strong> Infant/Child Defibrillator Pads.Adapter Model 05-10200Fits Philips hands-free cables M3507A or M1750A/B for connection toHewlett-Packard CodeMaster 100, XE, XL, and XL+; PhilipsHeartstream/HeartStart XL and XLT; HeartStart MRx and Laerdal<strong>Heartstart</strong> 4000 defibrillator/monitorsAdapter Model 05-10000Removable adapter for Medtronic Physio-Control Quik-Combo LifePak 9,10C, 11, 12, 20, and 500 defibrillatorsPermanent ConfigurationAdapter Model 05-10100Removable adapter for Zoll 1200, 1400, 1600 and M-Series defibrillatorsRemovable Configuration1. Tang, et al. Pediatric Fixed Energy Biphasic Waveform Defibrillation Using a Standard AED andSpecial Pediatric Electrodes. Supplement to Circulation,Vol 102, No 18, October 31, 2000, II-437.2. Cecchin, et al. Is Arrhythmia Detection by Automatic External Defibrillator Accurate for Children?Sensitivity and Specificity of an AED Algorithm in 696 Pediatric Arrhythmias. Circulation 2001;103:2483-2488, May 22, 2001.
Power <strong>Supplies</strong><strong>FR2</strong>-Series Standard BatteryItem #M3863A<strong>FR2</strong>-series defibrillators come with adisposable lithium manganese dioxide battery(M3863A), which has a shelf life of 5 years,plus typical standby life of 5 years (4 yearsminimum).**U.S. airline customers should order theFAA-certified version of this battery(989803136291).<strong>FR2</strong>+ Rechargeable BatteryItem #M3848AIn hospital and EMS environments, where theuseful life of a defibrillator’s disposable batterycan be consumed in a relatively short periodof time, the <strong>FR2</strong>+ Rechargeable Battery(M3848A) provides a cost-effective option forfrequent-use applications, such as back-to-backsudden cardiac arrest responses andmonitoring patients during transport.This Lithium-Ion battery fully charges(using the Charger M3849A) in just 3 hoursto provide 100 shocks (typical) or 5 hours(typical) of ECG display time.The “fuel gauge”on the <strong>FR2</strong>+ displays the battery’s remainingpower. Under normal conditions, the <strong>FR2</strong>+Rechargeable Battery withstands 300 chargedischargecycles or 2.5 years of use.<strong>FR2</strong>+ ECG Assessment ModuleIdeal where manual defibrillators and monitorsare impractical, the Philips <strong>FR2</strong>+ ECGAssessment Module enables the professionalresponder to use the HeartStart <strong>FR2</strong>+Defibrillator with ECG to assess the heartrhythms of conscious and/or breathing patientswho may be in cardiac distress.With thisreusable unit, caregivers knowledgeable inECG rhythms can use the defibrillator’s displayto view the Lead II ECG rhythm of a patientwho may be experiencing dizziness, chestdiscomfort, or becomes unconscious but is stillbreathing.***If arrhythmias are observed or the patient’sstatus changes, the responder can proactivelydetermine next steps. And if the patient goesinto cardiac arrest, the responder can reactimmediately by switching to defibrillationpads.The <strong>FR2</strong>+ ECG Assessment Module,compatible with most standard snapmonitoring electrodes, including M2202A(radioluscent foam), is available in twoconfigurations:Item #M3873AAAMI color convention with red, whiteand black leadwire connections.Item #M3874AIEC color convention with green, red andyellow leadwire connections.** Use of the defibrillator, additional battery insertion tests, or exposure to temperature extremesmay shorten the battery life.*** <strong>FR2</strong>+ ECG screen is not suitable for diagnostic and ST-segment interpretation.