NVMV SeriesEx Pendant Light Fittingsfor Zone 2 and 21


Ex-Pendant Light Fittings in Metal VersionNVMV for high pressure discharge lamps ofup to 400 W for zone 2/21The explosion-protected light fittings of theNVMV series are in accordance to theATEX Directive 94/9/EC.They have been built and tested according to theEuropean Standard for Gas-Ex-Areas of Zone 2classification as well as for use in Dust-Ex-Areasof Zone 21.The light fittings series NVMV with the small housingis designed for lamps with a rating of 70 W upto 250 W. The large housing is designed for lampswith a rating of 250 W and 400 W.The transparent part consists of a temperaturestable, impact resistant glass globe that refractsthe light and which is protected with a safetyguard as an option.The modular architecture allows for a quick andcost-effective installation of the light fittings. Apartfrom ceiling mounting, there are versions availablefor pole mounting (25° angle) and wall mounting.For pole mounting, a thread of 1 1/2” NPT is integratedin the light fitting.A particularly durable sealing system for use underextreme climatic conditions brings additionalreliability. The restricted breathing version allowsa high illumination combined with a hightemperature classification.With different external reflectors as an option, thelight can be distributed individually.Ideal for installation at low or mediumheights, for wall, ceiling or pole mountingCompact and light-weightHigh degree of protection IP66High corrosion resistanceFor ambient temperatures from-45 °C up to +55 °C2


???NVMV (SE) ceiling mounting Asymmetric reflectorNVMV (SE) wall mounting Wire guard NVMV (LE) pole mountingTechnical dataNVMV for high pressure discharge lamps up to 400 WMarking to 94/9/EC D II 3 G Ex nR II T 1 ) Gc / D II 2 D Ex tb IIIC T 1 ) °C Db IP 66Type Examination certificate (Gas) LCIE 10 ATEX 1005EC-Type Examination certificate (Dust) LCIE 10 ATEX 3029Permissible ambient temperature –45 °C up to +55 °CRated voltage230 V/50 Hz | 220-240 V/50-60 Hz (on request)Power factor cos ϕ > 0.9Connecting terminals L, N and PE; max. 6 mm 2Insulation classLamp capIE 27 (70 W HPS / 70-150 W MH)Light efficiency in operation 74 % (70-125 W)Degree of protection acc. to EN 60529Cable glands/gland plates | enclosure drillingDimensions (L x W x H)WeightEnclosure materialEnclosure colourProtective cover/protective bowlE 40 (100-400 W HPS / 250-400 W MH)78 % (250 - 400 W)IP66Drilling 4 x M 25 x 1.5 with blanking plugsee dimensions drawingsee ordering detailsLight alloy with epoxy powder coatingGreyBorosilicate glassAdditional lamp dataLamp Power Rated luminous Temperature class Surface temperature -45 °C up to +55 °Cflux 4 ) -45 °C up to +55 °C with reflector without reflector with reflectorNVMV... (small enclosure - SE)HSE 2 ) 70 W 5.600 lm T4 114 °C 119 °CHSE 2 ) 100 W 8.500 lm T4 114 °C 119 °CHSE 2 ) 150 W 14.500 lm T3 137 °C 155 °THSE 2 ) 250 W 27.000 lm T2 (T3 without reflector) 183 °C 204 °CHIE 3 ) 70 W 5.200 lm T4 114 °C 119 °CHIE 3 ) 100 W 8.500 lm T4 114 °C 119 °CHIE 3 ) 150 W 12.500 lm T3 137 °C 155 °CHIE 3 ) 250 W 19.000 lm T2 (T3 without reflector) 183 °C 204 °CNVMV... (large enclosure - LE)HSE 2 ) 250 W 27.000 lm T3 152 °C 152 °CHSE 2 ) 400 W 48.000 lm T3 174 °C 190 °CHIE 3 ) 250 W 19.000 lm T3 152 °C 152 °CHIE 3 ) 400 W 34.000 lm T2 (T3 without reflector) 174 °C 208 °C1) see table2) HSE = High pressure sodium lamp3) HIE = High pressure metal halide lamp4) Depends on manufacturer3


Ex-Pendant Light Fittings in Metal VersionOrdering detailsType Mounting HPS MH Lamp Weight Order-No.HSE/HST HIE/HIT current (approx.)NVMV... (small enclosure (SE) - 230 V/50 Hz)S2MC 075 O 00 Ceiling 70 W - 1.0 A 7.6 kg CCL 0 807 178 ES2MC 105 O 00 Ceiling 100 W - 1.2 A 7.6 kg CCL 0 807 184 ES2MC 155 O 00 Ceiling 150 W - 1.8 A 7.6 kg CCL 0 807 190 ES2MC 255 O 00 Ceiling 250 W - 3.0 A 7.6 kg CCL 0 807 196 EM2MC 075 O 00 Ceiling - 70 W 1.0 A 7.6 kg CCL 0 807 113 EM2MC 105 O 00 Ceiling - 100 W 1.2 A 7.6 kg CCL 0 807 119 EM2MC 155 O 00 Ceiling - 150 W 1.8 A 7.6 kg CCL 0 807 125 EM2MC 255 O 00 Ceiling - 250 W 3.0 A 7.6 kg CCL 0 807 137 ES2MW 075 O 00 Wall 70 W - 1.0 A 8.0 kg CCL 0 807 202 ES2MW 105 O 00 Wall 100 W - 1.2 A 8.0 kg CCL 0 807 208 ES2MW 155 O 00 Wall 150 W - 1.8 A 8.0 kg CCL 0 807 214 ES2MW 255 O 00 Wall 250 W - 3.0 A 8.0 kg CCL 0 807 220 EM2MW 075 O 00 Wall - 70 W 1.0 A 8.0 kg CCL 0 807 143 EM2MW 105 O 00 Wall - 100 W 1.2 A 8.0 kg CCL 0 807 149 EM2MW 155 O 00 Wall - 150 W 1.8 A 8.0 kg CCL 0 807 155 EM2MW 255 O 00 Wall - 250 W 3.0 A 8.0 kg CCL 0 807 167 ES5NJ 075 O 00 Pole 1 ) 70 W - 1.0 A 8.0 kg CCL 0 807 225 ES5NJ 105 O 00 Pole 1 ) 100 W - 1.2 A 8.0 kg CCL 0 807 226 ES5NJ 155 O 00 Pole 1 ) 150 W - 1.8 A 8.0 kg CCL 0 807 227 ES5NJ 255 O 00 Pole 1 ) 250 W - 3.0 A 8.0 kg CCL 0 807 228 EM5NJ 075 O 00 Pole 1 ) - 70 W 1.0 A 8.0 kg CCL 0 807 172 EM5NJ 105 O 00 Pole 1 ) - 100 W 1.2 A 8.0 kg CCL 0 807 173 EM5NJ 155 O 00 Pole 1 ) - 150 W 1.8 A 8.0 kg CCL 0 807 174 EM5NJ 255 O 00 Pole 1 ) - 250 W 3.0 A 8.0 kg CCL 0 807 176 ENVMV... (Large enclosure (LE) - 230 V/50 Hz)S2MC 255 OL 0 Ceiling 250 W - 3.0 A 21.0 kg CCL 1 030 119 ES2MC 405 OL 0 Ceiling 400 W - 4.6 A 21.0 kg CCL 1 030 145 EM2MC 255 OL 0 Ceiling - 250 W 3.0 A 21.0 kg CCL 1 030 106 EM2MC 405 OL 0 Ceiling - 400 W 4.2 A 21.0 kg CCL 1 030 132 ES2MW 255 OL 0 Wall 250 W - 3.0 A 21.4 kg CCL 1 030 125 ES2MW 405 OL 0 Wall 400 W - 4.6 A 21.4 kg CCL 1 030 151 EM2MW 255 OL 0 Wall - 250 W 3.0 A 21.4 kg CCL 1 030 112 EM2MW 405 OL 0 Wall - 400 W 4.2 A 21.4 kg CCL 1 030 138 ES5NJ 255 OL 0 Pole 1 ) 250 W - 3.0 A 21.4 kg CCL 1 030 130 ES5NJ 405 OL 0 Pole 1 ) 400 W - 4.6 A 21.4 kg CCL 1 030 156 EM5NJ 255 OL 0 Pole 1 ) - 250 W 3.0 A 21.4 kg CCL 1 030 117 EM5NJ 405 OL 0 Pole 1 ) - 400 W 4.2 A 21.4 kg CCL 1 030 143 E1) Thread 1 ½“ NPTAccessoriesType for small enclosure (SE)Order-No.Guard P 22 in stainless steel 7824Globe G251 10678External reflector, symetric, RD 70 (70 - 250 W) 11758External reflector, asymetric, RA 70 (70 - 250 W) 9620Champ quick-clip S 890 mounting accessories 11923847Pendant mounting bracketCHR7326Type for large enclosure (LE)Order-No.Guard P 33 in stainless steel 26249External reflector, symetric, RD 739 (250 - 400 W) 2590External reflector, asymetric, RA 739 (250 - 400W) 2588Champ quick-clip S 890 mounting accessories 11923847Pendant mounting bracketCHR73264


678491422609429602634NVMV (SE) ceiling mounting Asymmetric reflectorNVMV (SE) pole mounting Wire guard NVMV (LE) pole mountingDimensions drawingNVMV with small enclosure (SE)AccessoriesPendant mounting300Ceiling mounting295Wall mounting35594.54x894.5118Pole mounting392448External reflector RD 70 (symetric)133Ø 429External reflector RA 70 (asymetric)25°25430°Ø 370Pendant mounting bracketNVMV with large enclosure (LE)27669300Pendant mounting300Ceiling mounting295Wall mounting94.54x8355Pole mounting518External reflector RD 739 (symetric)13594.5118Ø 429External reflector RA 739 (asymetric)25°25430°251276Ø 370Dimensions in mm5


Ex-Pendant Light Fittings in Metal VersionNVMV (SE) ceiling mounting NVMV (SE) with reflector ASNVMV (SE) wall mounting NVMV (LE) pole mounting NVMV (LE) with wire guardPolar curvesNVMV with small enclosure (SE)Polar curve NVMV 70 - 250 W(with external reflector RD 70)120 120Polar curve NVMV 70 - 250 W(with external reflector RA 70)120 120Polar curve NVMV 70 - 250 W(without external reflector)120 1209090909090903040206060906060801206060406060C 0C 9030120150030l/cd/klmC 0C 9030160200030l/cd/klmC 0/903080100030l/cd/klmNVMV with large enclosure (LE)Polar curve NVMV 250 - 400 W(with 120 external reflector RD 739) 120Polar curve NVMV 250 - 400 W(with 120 external reflector RA 739) 120Polar curve NVMV 250 - 400 W(without 120 external reflector)120909090909090253020605075606060906060406060C 0C 9030100125030l/cd/klmC 0C 9030120150030l/cd/klmC 0C 903080100030l/cd/klm6


Certification –The basis for safetyIn addition to conformity with technical standards,the issue of approvals by so-called“notified bodies” (ATEX Directive 94/9/EC) is partof our day-to-day business. Individual components,sub-assemblies and completeinstallations are tested and certified byindependent authorities. That certificate is thebasis for the issue of the “Declaration ofConformity”, which assures you, our customer,that all the important requirements forexplosion protection have been fulfilled.You can only be certain of the safety of theinstallation if you have such official declaration.With us you have a strong and competent partnerfor all matters of explosion protection operating allover the world.Quality without short-cutsComprehensive quality assurance systems –certified, of course, to the latest directivesISO 9001-2008 – are the basis for our day-to-daybusiness.Before our products are made available to you,we make sure that they fulfill even the moststringent requirements, because you must be ableto rely on them in the event of an emergency.Our technical solutions protect both property andlive. Our customers view us as a trusted partnerfor safety. Quality has top priority for our highlyqualified employees and governs their actions.The final inspection of our products is only one ofthe process steps for quality assurance to provideyou with highest safety standards.This pays off because our products have toremain fully functional at all times, even under themost adverse ambient conditions.For this reason, for decades now, our productsand solutions are in use in locations whereutmost reliability is key.7


<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> GmbHNeuer Weg – Nord 49D-69412 EberbachTelefon +49 (0) 6271/806-500Fax +49 (0) 6271/806-476Internet www.ceag.deE-Mail sales.CCH.de@cooperindustries.com<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> S.A.Avda. Santa Eulalia, 290E - 08223 TerrassaBarcelonaTelefon +34 (0) 9-37362710Fax +34 (0) 9-37835055E-Mail sales.CCH.es@cooperindustries.com<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> LLCSuite 302, Building 49Dubai Healthcare CityDubaiUnited Arab EmiratesPhone: 971-4-427-2522 / 2500Fax: 971-4-429-8521E-Mail sales.CCH.me@cooperindustries.com<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> (UK) Ltd.Unit G, Quinn CloseSeven Stars Industrial EstateWhitleyGB - Coventry CV 3 4LHTelefon +44 247-630-89 30Fax +44 247-630-10 27E-Mail sales.CCH.gb@cooperindustries.com<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> B. V.Sydneystraat 74NL - 3047 BP RotterdamTelefon +31 (0) 10-2452145Fax +31 (0) 10-2452121E-Mail sales.CCH.nl@cooperindustries.com<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> Norge A/SHusebysletta 9N - 3412-LierstrandaTelefon +47 32-244600Fax +47 32-244646E-Mail sales.CCH.no@cooperindustries.comCOOPER Industries <strong>Crouse</strong>-<strong>Hinds</strong> DivisionWolf 7th North StreetsP. O. Box 4999USA - Syracuse, NY 13221Telefon +1 (0) 3-154777000Fax +1 (0) 3-154775717E-Mail crouse.customerctr@cooperindustries.comInternet www.crouse-hinds.com<strong>Cooper</strong> Electric (Shanghai) Co. Ltd.3rd FloorNo.6101 LongDong AvenuePudong Shanghai, China 201201Telefon +86-21-68915655E-Mail CCHSales@cooperindustries.com<strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> Pte. Ltd.2 Serangoon North Avenue 5Fu Yu Building #06-01SGP - 554911SingaporePhone +65 (0) 6297-4849Fax +65 (0) 6297-4819E-Mail chsi-sales@cooperindustries.comInternet www.cchspore.com.sg/©2010 <strong>Cooper</strong> <strong>Crouse</strong>-<strong>Hinds</strong> GmbHSome of the information might lack topicality, correctness and completeness. Liability claims in regards to the presented information cannot be accepted.<strong>Cooper</strong> Industries, Ltd.600 Travis, Ste. 5800Houston, TX 77002-1001P: 713-209-8400Internet www.cooperindustries.com30080002164/2.5/07-10/Flyer Valid from July 2010