LOWER PROFILE<br />

ENHANCED ACCESS<br />

<strong>Endurant</strong> <strong>II</strong> takes improved access a step further, offering an 18 F crossing profile<br />

for its 28 mm bifurcated device. With extended hydrophilic coating, the same<br />

thin-walled graft cover and flexible, kink-resistant delivery system as <strong>Endurant</strong>,<br />

<strong>Endurant</strong> <strong>II</strong> delivers improved ease of use.<br />

BIFURCATED AAA DEVICE OUTER DIAMETER PROFILES<br />

28 mm <strong>Medtronic</strong> <strong>Endurant</strong> <strong>II</strong>, Cook Zenith Bifurcated Devices and 28.5 mm Gore Excluder Bifurcated Device<br />

Crossing Profile (OD) 18 F 20 F 1 23 F 2<br />

Hydrophilic Coating<br />

Sheath Required<br />

<strong>Medtronic</strong><br />

<strong>Endurant</strong> <strong>II</strong><br />

Yes<br />

No<br />

Gore<br />

Excluder<br />

No<br />

Yes<br />

Cook<br />

Zenith<br />

Yes<br />

Yes<br />

100%<br />

delivery/deployment<br />

success 3<br />

Hydrophilic coating extends 35% further down the catheter to facilitate stent graft delivery 4<br />

BIFUR DIAMETER<br />

28mm, 25mm, 23mm 18F (OD) *<br />

36mm, 32mm 20F (OD) *<br />

LIMB DIAMETER<br />

16mm, 13mm, 10mm † 14F (OD) *<br />

28mm, 24mm, 20mm 16F (OD) *<br />

*Outer diameter<br />

† All 156 & 199 mm limbs are 16 F<br />

1. Bench test data on file at <strong>Medtronic</strong>, Inc. Bench test data may not be indicative of clinical performance. The Gore Excluder IFU recommends using an<br />

18 F Gore Introducer Sheath with its 28.5 mm Gore Excluder bifurcated main body device. The Gore DrySeal Sheath IFU indicates that the nominal<br />

OD of an 18 F Gore DrySeal Sheath is 6.8 mm, which is 20.4 F.<br />

2. Bench test data on file at <strong>Medtronic</strong>, Inc. Bench test data may not be indicative of clinical performance. Cook’s Physician Manual indicates that the<br />

OD of a 28 mm Cook Zenith bifurcated main body device is 7.7 mm, which is 23.1 F.<br />

3. Delivery Success = successful vascular access and delivery of the device to the intended anatomical treatment site. Deployment Success = successful<br />

deployment of the device in the intended site and the successful removal of the delivery system. <strong>Endurant</strong> EU trial: Rouwet EV et al. Final results<br />

of the prospective European trial of the <strong>Endurant</strong> stent graft for endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg.<br />

2011;42(4):489–497.<br />

4 ENDURANT <strong>II</strong> AAA STENT GRAFT SYSTEM<br />

4. <strong>Endurant</strong> <strong>II</strong> features 50.8 cm hydrophilic coating.<br />

5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!