AccessoriesREGENAIR ® Regenerative BlowersFiltersInlet filters (for pressure)Part No. Dim. A Dim. B Dim. C Filter Replacement Used OnAJ126B 6.00” 4.62” 1” MPT AJ134B (10 micron) R1, R2AJ126C 6.00” 7.12” 1 1 / 4” MPT AJ134C (10 micron) R3AJ126D 7.70” 7.25” 1 1 / 2” MPT AJ134E (10 micron) R4, R4H, R4P, R5AJ126F 10.63” 4.81” 2” MPT AG340 (10 micron) R6, R6P, R6PS, R6PP, R9AJ126G 10.00” 13.12” 2 1 / 2” MPT AJ135A (10 micron) R7, R7P,AJ126L 10.00” 14.62” 4” MPT AJ135C (10 micron) Consult factoryAJ126M 16.00” 14.62” 5” MPT AJ135H (10 micron) Consult factoryMPT = Male Pipe Thread. FPT = Female Pipe Thread. All are heavy-duty for high amounts of particulates.Inlet filters for REGENAIR ® blowers are drip-proof when mounted as shown.FiltersIn locations where there are high amounts of dust, powder, or dirt suspended in the air, inline filters (for vacuum applications)and inlet filters (pressure applications), should be used. Keeping particulates from entering the blower will ensuresmooth operation and trouble free service life.Inline filters (for vacuum)AV seriesPart No. Dim. A Dim. B Dim. C Dim. D Used OnAV460 8 1 / 4” 8 7 / 8” 1” FPT 1” FPT R1, R2AV460C 8 1 / 4” 8 7 / 8” 1 1 / 4” FPT 1 1 / 4” FPT R3FReplacement elements for AV460 and AV460C:AV463A - Cloth bag, 50 micron, sold in 3 pack (letter F on diagram).AV469A - Paper filter, 5-10 micron, sold in 12 pack (letter E on diagram).AJ seriesPart No. Dim. A Dim. B Dim. C Dim. D Dim.E Filter Replacement Used OnAJ151A 5.88” 4.50” 2.75” 1” FPT 1” FPT AJ135D (10 micron) R1AJ151B 7.38” 6.81” 4.62” 1” FPT 1” FPT AJ135E (10 micron) R2AJ151C 7.38” 6.81” 4.62” 1 1 / 4” FPT 1 1 / 4” FPT AJ135E (10 micron) R3AJ151D 7.38” 6.81” 4.62” 1 1 / 2” FPT 1 1 / 2” FPT AJ135E (10 micron) R4, R4PAJ151E 8.75” 10.25” 5.00” 2” FPT 2” FPT AJ135F (10 micron) R4H, R4P, R5AJ151G 8.75” 10.50” 5.50” 2 1 / 2” FPT 2 1 / 2” FPT AJ135G (10 micron) R6, R6P,AJ151H 14.00” 27.13” 18.50” 3” MPT 3” MPT AJ135C (10 micron) R6PP, R6PS, R7AJ151M 18.50” 28.13” 19.50” 5” MPT 5” MPT AJ135H (10 micron) R7P, R7S, R9, R9P, R9SMPT = Male Pipe Thread. FPT = Female Pipe Thread. All are heavy-duty for high amounts of particulates.Inline filters for REGENAIR ® blowers are drip-proof when mounted as shown.66 <strong>Gast</strong> Regenair® Regenerative Blowers www.gastmfg.com
AccessoriesREGENAIR ® Regenerative BlowersRegenair ® Filter Restrictions with Clean ElementInlet FiltersBlower Filter Restriction ininH 2O at CFM FlowIndicatedR1 AJ126B 2.2” @ 27 CFMR2 AJ126B 4.5” @ 40 CFMR3 AJ126C 2.5” @ 50 CFMR4H AJ126D 8” @ 120 CFMR4 AJ126D 4” @ 85 CFMR4P AJ126D 8” @ 120 CFMR5 AJ126D 11” @ 146 CFMR6 AJ126F 7” @ 200 CFMR6P/R6PS AJ126F 11” @ 265 CFMR6PP (2) AJ126F 10” @ 240 CFMR7/R7S AJ126G 12” @ 400 CFMR7P (2) AJ126G 12”@ 400 CFMR9S AJ126M Consult factoryR9P AJ126M Consult factoryInline FiltersBlower Filter Restriction inSize Number inH 2O at CFM FlowIndicatedR1 AJ151A 1” @ 25 CFMAV4602” @ 25 CFMR2 AJ151B 2” @ 40 CFMAV4605” @ 40 CFMR3 AJ151C 2” @ 50 CFMAV460C3” @ 50 CFMR4 AJ151D 3” @ 100 CFMR4P AJ151E 3” @ 100 CFMR4H AJ151E 3” @ 120 CFMR5 AJ151E 4” @ 160 CFMR6 AJ151G 2” @ 200 CFMR6P/R6PS AJ151G 3” @ 300 CFM6PP AJ151H 8”@ 400 CFMR9S AJ151 M Consult factoryR9P AJ151 M Consult factorywww.gastmfg.com<strong>Gast</strong> Regenair® Regenerative Blowers 67