12.07.2015 Views

Calibration and Setup Procedures

Calibration and Setup Procedures

Calibration and Setup Procedures

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C.11 Pipeline Bus BackplaneReadout of data from the PPMs to the PPROD is via the custom pipeline busbackplane in the PreProcessor crates. This consists partly of PCB <strong>and</strong> also someflat cable connections. We should have a procedure to verify that the pipeline busis working correctly.Procedure: use the PPM playback memories. Load suitable test patterns <strong>and</strong>thresholds in all PPMs, read a few events from the PPRODs <strong>and</strong> check that eachchannel is receiving valid data from the correct originating module.C.12 Glink cables to CPRODsReadout of data from the CPMs, JEMs <strong>and</strong> CMMs is via Glink cables to theCPRODs. The Glink data packets from these modules do not themselves identifythe originating module. The CPROD firmware is expected to blithely encode themodule addresses of incoming data on the basis of the Glink input number. It isimportant that the correct cabling of the Glink inputs is checked.Procedure: use the CPM, JEM <strong>and</strong> CMM playback memories. Load suitabletest patterns <strong>and</strong> thresholds in all CPMs, JEMs <strong>and</strong> CMMs, read a few events fromthe CPRODs <strong>and</strong> check that each Glink input is receiving data from the correctoriginating module.C.13 PPROD <strong>and</strong> CPRODs to the ROSEach ROD sends its data to the DAQ Readout System (ROS) on one Slink connection.Although each ROD packet will uniquely identify its source ROD, weshould check that the physical connections are actually the expected ones. Thiswill be required for correct subpartitioning of the system for tests.Procedure: use the ROD playback memories. Load suitable Slink packets intothe RODs, read a few events from the ROS <strong>and</strong> check that each Slink connectionis as expected.C.14 CPRODs to the ROIBThose of the CPRODs which process ROIs will send their formatted ROI packetsvia Slink connections to the ROI builder (ROIB). Although the ROI packets donot uniquely distinguish between different kinds of ROI, the packets will containthe source ROD identifier, so the ordering of cables at the ROIB inputs may notbe important (check). Anyway it can be simply checked.16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!