12.07.2015 Views

MAGNETIC BALLASTS

MAGNETIC BALLASTS

MAGNETIC BALLASTS

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1850 Wilson Ave, Toronto,Ontario, Canada, M9M 1A1Ph: 416-741-7336 Fax: 416-741-9104Web: http://www.etlin.comSECTIONB<strong>MAGNETIC</strong><strong>BALLASTS</strong>B1Magnetic BalastsSuffix GuidelineT5 Straight LampsT8 Straight LampsT12 Straight LampsCompact LampsCircline LampsSign BallastsGlossary/AppendixB1B2B3 - B4B5 - B8B9 - B10B11B12B13 -Etlin–Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation. While everyeffort is made to ensure that descriptions, and other information in this catalogue are correct, no warranty is given in respect thereofand the company shall not be liable for any error heroin.Copyright 2008 © Etlin-Daniels


MagneticBallastGuidline to Etlin DanielsModel SuffixB2Guideline to Etlin Daniels ModelSuffix Guidline-1 120V INPUT LINE VOLTAGE-2 277V INPUT LINE VOLTAGE-3 347V INPUT LINE VOLTAGE-4 480V INPUT LINE VOLTAGE-AAAluminum Primary Winding, Aluminum Secondary Winding-ADADAPTER-ALALUMINUM CASE-CACopper Primary Winding, Aluminum Secondary Winding-CCCLAMP CORE-D DOUBLE TAP INPUT VOLTAGE (120V, 277V)-DIM DIMMABLE-DWDUAL WAY CONNECTOR-EBF BF = 0.77-EMI COMPLY WITH FCC CLASS B REQUIREMENT-ENENCASED-FCFINGER CAN-HBF BF = 0.88-HPHIGH POWER FACTOR-HV120V OUTPUT VOLTAGE-IESINTERNAL ELECTRONIC STARTER-IVINTERNAL VOLTAGE (90V-240V)-LBF BF = 0.88-LCLARGE CAN-LDIM LOCAL DIMMABLE-LSWITH LEAD WIRE-LHLOW HEAT-MCWITH MOUNTING CUP-OCOPEN CORE-P 5 TAP INPUT VOLTAGE (120V, 208V, 240V, 277V, 480V)-PFWITH SINGLE BLOW THERMAL FUSE-PGPLUG-IN-PNPLASTIC ENCASED-PIC ACTIVE POWER FACTOR CORRECTION-PHPRE-HEAT START-PSPROGRAMMED START-PSD PROGRAMMED START & DUAL WAY CONNECTOR-RJRECESSED JUNCTION BOX WITHOUT BOTTOM STUD-RJS RECESSED JUNCTION BOX WITH BOTTOM STUD-Q QUAD TAP INPUT VOLTAGE (120V, 208V, 240V, 277V)-Q3 QUAD TAP INPUT VOLTAGE (120V, 208V, 240V, 347V)-SCP SHORT CIRCUIT PROTECTION-SCS SHORT CAN WITH BOTTOM STUDS-SCSHORT CAN WITHOUT BOTTOM STUDS-SLSLIM CAN-SLL LONG SLIM CAN-SSSELF-START-TPCLASS P BALLAST-UVUNIVERSAL LINE INPUT VOLTAGE (120V-277V)-WC WITH CORD-WS WITH CIRCLINE SOCKETFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


Magnetic Ballasts forFluorescent LampsMagneticBallastT8 Straight LampsB5LampWattsLampType30 F30T8No. ofLampsCat.Number1 N-140A-1-TP WSInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 N-140A-1-TP-SS 120 0.60 36 > 0.50 < 15 0.88 UL, cUL PH 6 D1WiringDia.DimensionsUL, cUL PH 16 D11 N-140A-1-TP-WC UL, cUL PH 17 D11 N-132-1-TP WS 120 0.52 33 > 0.50 < 20 0.84 UL, cUL RS 4 D1Magnetic Ballasts32 F32T81 N-132SL-1-TP 120 0.52 33 > 0.50 < 20 0.84 UL, cUL RS 4 C6/J11 N-132-1-TP-HP 120 0.31 33 > 0.90 < 20 0.84 UL, cUL RS 4 D12 ES-232-1-TP WS 120 0.65 70 > 0.90 < 10 0.90 UL, cUL RS 5 C22 ES-232-2-TP 277 0.28 70 > 0.90 < 10 0.90 UL, cUL RS 5 C2WS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


MagneticBallastMagnetic Ballasts forFluorescent LampsB6T12 Straight LampsMagnetic BallastsLampWattsLampType14 F14T12No. ofLampsCat.NumberInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 CF-1322-CC WS *UL, CSA PH 1 B2120 0.33 16 > 0.40 < 15 0.801 CF-1322-OC * % UL, CSA PH 1 A21 CF-1322M-CC WS *UL, cUL PH 1 B2120 0.33 16 > 0.40 < 15 0.801 CF-1322M-OC * % UL, cUL PH 1 A21 CF-1320S-CC WS *1 CF-1320S-OC WS * % UL, cUL PH 1 A4120 0.33 16 > 0.40 < 15 0.801 CF-1320LH-OC * UL, cUL PH 1 A4WiringDia.DimensionsUL, cUL PH 1 B41 CF-1320LH-CC * UL, cUL PH 1 B41 N-120-1-TP WS 120 0.69 29 > 0.35 < 10 0.93 UL, cUL TS 4 D11 CF-1322-CC WS *120 0.32 17 > 0.45 < 15 0.85 UL, cULPH 1 B21 CF-1322-OC * % UL, cUL PH 1 A21 CF-1322M-CC WS *UL, cUL PH 1 B2120 0.32 17 > 0.45 < 15 0.851 CF-1322M-OC * % UL, cUL PH 1 A21 CF-1320S-CC WS *UL, cUL PH 1 B415 F15T121 CF-1320S-OC WS * % UL, cUL PH 1 A4120 0.32 17 > 0.45 < 15 0.851 CF-1320LH-OC * UL, cUL PH 1 A41 CF-1320LH-CC * UL, cUL PH 1 B41 CF-1540-1-TP-IES WS 120 0.35 17 > 0.40 < 20 0.90 UL, cUL IES 19 C71 N-120-1-TP WS 120 0.63 31 > 0.40 < 10 1.0 UL, cUL TS 4 D12 N-220-1-TP WS 120 0.65 35 > 0.45 < 20 0.70 UL, cUL TS 5 C11 CF-1322-CC WS *UL, CSA PH 1 B2120 0.24 17 > 0.60 < 15 0.651 CF-1322-OC * % UL, CSA PH 1 A21 CF-1322M-CC WS *UL, cUL PH 1 B2120 0.24 17 > 0.60 < 15 0.651 CF-1322M-OC * % Ul, cUL PH 1 A21 CF-1320S-CC WS *UL, cUL PH 1 B420 F20T12 1 CF-1320S-OC WS * % UL, cUL PH 1 A4120 0.24 17 > 0.60 < 15 0.651 CF-1320LH-OC * UL, cUL PH 1 A41 CF-1320LH-CC * UL, cUL PH 1 B41 CF-1540-1-TP-IES WS 120 0.33 20 > 0.50 < 25 0.83 UL, cUL IES 19 C71 N-120-1-TP WS 120 0.62 30 > 0.40 < 10 0.85 UL, cUL TS 4 D12 N-220-1-TP WS 120 0.59 35 > 0.50 < 20 0.54 UL, cUL TS 5 C125 F25T12 1 CF-25-WC-TP 120 0.31 22 > 0.60 < 20 0.70 UL, cUL PH 17 G2* Add –PF for single blow thermal fuse or –TP for resettable thermal protector % Replace –OC by –WC for With Cord model# Add –WS for standard bi-pin lampholders attached @ Add –LC for using 9” long canWS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


Magnetic Ballasts forFluorescent LampsMagneticBallastT12 Straight LampsB7LampWattsLampTypeNo. ofLampsCat.Number1 N-140A-1-TP WSInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 N-140A-1-TP-SS 120 0.67 35 > 0.40 < 10 0.87 UL, cUL PH 6 D1WiringDia.DimensionsPH 16 D11 N-140A-1-TP-WC PH 17 D1Magnetic Ballasts30 F30T121 N-140-1-TP WS 120 0.61 33 > 0.45 < 10 0.95 UL, cUL RS 4 D11 CF-1540-1-TP-IES WS 120 0.33 20 > 0.50 < 25 0.83 UL, cUL IES 19 C72 ES-240J-1-TP 120 0.66 75 > 0.95 < 20 0.97 UL, cUL RS 5 C22 ES-230-1-TP 120 0.55 64 > 0.95 < 20 0.75 UL, cUL RS 5 C21 N-140-1-TP WS 120 0.55 30 > 0.45 < 10 0.70 UL, cUL RS 4 D11 CF-1540-1-TP-IES WS 120 0.31 30 > 0.80 < 40 0.66 UL, cUL IES 19 C725 F40T122 N-240-1-TP # @ 120 0.58 45 > 0.65 < 20 0.50 UL, cUL RS 5 C12 N-234-1-TP # @ 120 0.52 41 > 0.65 < 20 0.36 UL, cUL RS 5 C12 N-240-1-TP-IES 120 0.64 58 > 0.75 < 40 0.60 UL, cUL IES 20 D12 LW-240-1-TP 120 0.58 66 > 0.95 < 30 0.67 UL, cUL RS 5 C2# Add –WS for standard bi-pin lampholders attached @ Add –LC for using 9” long canWS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


MagneticBallastMagnetic Ballasts forFluorescent LampsB8T12 Straight LampsMagnetic BallastsLampWattsLampTypeNo. ofLampsCat.NumberInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 N-140-1-TP WS 120 0.63 34 > 0.45 < 10 0.70 UL, cUL RS 4 D11 CF1540-TP-IES WS 120 0.38 25 > 0.50 < 40 0.69 UL, cUL IES 19 C71 ES-140N-1-TP WS 120 0.38 44 > 0.95 < 15 0.88 UL, cUL RS 6 C21 ES-140N-2-TP 277 0.17 46 > 0.95 < 15 0.90 UL, cUL RS 6 C2WiringDia.Dimensions2 N-234-1-TP # @ 120 0.80 53 > 0.55 < 15 0.60 UL, cUL RS 5 C134F40T12Energy Saver2 LW-240-1-TP 120 0.47 51 > 0.90 < 40 0.60 UL, cUL RS 5 C22 N-240-1-TP-IES 120 0.70 51 > 0.60 < 40 0.60 UL, cUL IES 20 D12 ES-240N-1-TP 120 0.64 75 > 0.95 < 25 0.88 UL, cUL RS 5 C22 ES-240J-1-TP 120 0.70 76 > 0.90 < 20 0.88 UL, cUL RS 5 C22 ES-240N-2-TP 277 0.30 78 > 0.95 < 20 0.90 UL, cUL RS 5 C22 ES-240N-3-TP 347 0.22 76 > 0.95 < 20 0.90 UL, cUL RS 5 C21 N-140-1-TP WS 120 0.61 37 > 0.50 < 10 0.64 UL, cUL RS 4 D11 N-140A-1-TP WSUL, cUL PH 16 D11 N-140A-1-TP-SS 120 0.60 36 > 0.50 < 10 0.72 UL, cUL PH 6 D11 N-140A-1-TP-WC UL, cUL PH 17 G11 CF-1540-1-TP-IES WS 120 0.31 30 > 0.80 < 40 0.66 UL, cUL IES 19 C71 ES-140N-1-TP WS 120 0.44 51 > 0.95 < 15 0.93 UL, cUL RS 6 C21 ES-140N-2-TP 277 0.19 52 > 0.95 < 15 0.94 UL, cUL RS 6 C240 F40T122 N-240-1-TP # @ 120 0.64 50 > 0.65 < 20 0.45 UL, cUL RS 5 C12 N-234-1-TP # @ 120 0.52 41 > 0.50 < 20 0.36 UL, cUL RS 5 C12 N-240-1-TP-IES 120 0.65 59 > 0.75 < 40 0.60 UL, cUL IES 20 D12 ES-240N-1-TP 120 0.77 88 > 0.95 < 20 0.91 UL, cUL RS 5 C22 LW-240-1-TP 120 0.57 66 > 0.95 < 30 0.67 UL, cUL RS 5 C22 ES-240J-1-TP 120 0.77 88 > 0.95 < 20 0.90 UL, cUL RS 5 C22 LE-240-1-TP 120 0.68 80 > 0.95 < 20 0.81 UL, cUL RS 5 C22 ES-240N-2-TP 277 0.33 88 > 0.95 < 20 0.91 UL, cUL RS 5 C22 ES-240N-3-TP 347 0.25 86 > 0.95 < 20 0.90 UL, cUL RS 5 C2# Add –WS for standard bi-pin lampholders attached @ Add –LC for using 9” long canWS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


Magnetic Ballasts forFluorescent LampsMagneticBallastT12 Straight LampsB9Lamp Lamp No. of Cat. Input Input Input Power THD Ballast Approvals Starting Wiring Dimen-55 F72T121 ES-196-1-TP WS 120 0.73 78 < 0.90 < 30 0.80 UL, cUL IS 25 D41 ES-196-2-TP 277 0.30 76 > 0.90 < 35 0.80 UL, cUL IS 25 D42 ES-275-1-TP WS * 120 0.90 98 > 0.90 < 40 0.68 UL, cUL IS 8 D2,D42 ES-296N-1-TP 120 1.20 133 > 0.95 < 25 0.88 UL, cUL IS 8 D22 ES-296-2-TP 277 0.51 133 > 0.95 < 25 0.90 UL, CSA, IS 15 D22 ES-296-3-TP 347 0.40 130 > 0.95 < 40 0.90 PENDING IS 15 D21 ES-196-1-TP WS 120 0.73 78 > 0.90 < 40 0.71 UL, cUL IS 25 D41 ES-196-2-TP 277 0.30 76 > 0.90 < 40 0.73 UL, cUL IS 25 D4Magnetic Ballasts60F96T12Energy Saver2 ES-275-1-TP WS * 120 1.1 127 > 0.95 < 30 0.72 UL, cUL IS 8 D2,D42 ES-296N-1-TP 120 1.20 133 > 95 < 25 0.88 UL, cUL IS 8 D22 ES-296-2-TP 277 0.53 131 > 0.90 < 40 0.74 UL, CSA, IS 15 D22 ES-296-3-TP 347 0.40 132 > 0.90 < 40 0.9 PENDING IS 15 D21 ES-196-1-TP WS 120 0.83 93 > 0.90 < 30 0.75 UL, cUL IS 25 D42 ES-275-1-TP WS * 120 1.36 158 > 0.95 < 30 0.75 UL, cUL IS 8 D2,D475 F96T121 ES-196-2-TP 277 0.36 93 > 0.90 < 40 0.76 UL, cUL IS 25 D42 ES-296N-1-TP 120 1.40 160 > 0.95 < 25 1.0 UL, cUL IS 8 D22 ES-296-2-TP 277 0.53 131 > 0.90 < 40 0.74 UL, CSA, IS 15 D22 ES-296-3-TP 347 0.46 154 > 0.95 < 40 0.9 PENDING IS 15 D21 ES-196HO-1-TP WS 120 1.1 123 > 0.90 < 35 1.0 UL, cUL RS 6 D81 ES-196HO-2-TP 277 0.46 118 > 0.90 < 35 0.97 UL, cUL RS 6 D885 F72T12/HO2 ES-296HO-1-TP WS 120 1.85 207 > 0.90 < 20 0.94 UL, cUL RS 5 D896F96T12/HO ESEnergy Saver2 ES-296HO-2-TP 277 0.76 202 > 0.95 < 25 0.94 UL, cUL RS 5 D82 ES-296HO-3-TP 347 0.54 186 > 0.95 < 40 0.86 UL, cUL RS 5 D81 ES-196HO-1-TP 120 1.4 155 > 0.90 < 40 1.0 UL, cUL RS 6 D81 ES-196HO-2-TP 277 0.50 123 > 0.90 < 40 0.91 UL, cUL RS 6 D82 ES-296HO-1-TP WS 120 1.95 220 > 0.92 < 20 0.93 UL, cUL RS 5 D82 ES-296HO-2-TP 277 0.78 210 > 0.95 < 15 0.90 UL, cUL RS 5 D82 ES-296HO-3-TP 347 0.57 195 > 0.95 < 20 0.82 UL, cUL RS 5 D81 ES-196HO-1-TP 120 1.2 130 > 0.90 < 40 0.95 UL, cUL RS 6 D81 ES-196HO-2-TP 277 0.58 147 > 0.90 < 40 0.98 UL, cUL RS 6 D8110 F96T12/HO2 ES-296HO-1-TP 120 2.2 260 > 0.95 < 10 0.95 UL, cUL RS 5 D82 ES-296HO-2-TP 277 0.94 254 > 0.95 < 10 0.95 UL, cUL RS 5 D82 ES-296HO-3-TP 347 0.65 230 > 0.95 < 20 0.86 UL, cUL RS 5 D8* For model without thermal protector, remove –TP suffixWS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


MagneticBallastMagnetic Ballasts forCompact Fluorescent LampsB10Compact LampsMagnetic BallastsLampWattsLampType5 CFT5W/G237 CFT7W/G239 CFT9W/G23No. ofLampsCat.NumberInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 CF-49-OC-TP %UL, cUL PH 2 A1120 0.13 8 > 0.50 < 15 0.771 CF-49-CC-TP WS % UL, cUL PH 2 B11 CF-49M-1-OC *UL, cUL PH 2 A2120 0.20 9.5 0.40 < 15 1.121 CF-49M-1-CC * UL, cUL PH 2 B21 CF-49-OC-TP %UL, cUL PH 2 A1120 0.13 8 > 0.50 < 15 0.771 CF-49-CC-TP WS % UL, cUL PH 2 B11 CF-49M-1-OC *UL, cUL PH 2 A2120 0.18 10.5 0.49 < 15 1.01 CF-49M-1-CC * UL, cUL PH 2 B21 CF-579-OC-TP %UL, cUL PH 2 A1120 0.15 9 > 0.50 < 15 0.871 CF-579-CC-TP UL, cUL PH 2 B11 CF-49-OC-TP %UL, cUL PH 2 A1120 0.13 8 > 0.50 < 15 0.771 CF-49-CC-TP WS % UL, cUL PH 2 B11 CF-49M-1-OC *UL, cUL PH 2 A2120 0.15 11 > 0.50 < 15 0.901 CF-49M-1-CC * UL, cUL PH 2 B21 CF-579-OC-TP %UL, cUL PH 2 A1120 0.15 9 > 0.50 < 15 0.751 CF-579-CC-TP UL, cUL PH 2 B11 CF-1322-OC-TP %UL, CSA PH 2 A2120 0.30 16 > 0.45 < 15 0.931 CF-1322-CC-TP WS UL, CSA PH 2 B21 CF-1322M-OC-TP %UL, CSA PH 2 A2120 0.26 16 > 0.50 < 15 0.931 CF-1322M-CC-TP WS UL, CSA PH 2 B21 CF-1322-WC-TPUL, cUL PH 17 G2120 0.26 16 > 0.50 < 15 0.901 CF-1322-PG-TP UL, cUL PH 17 E1WiringDia.Dimensions13CFT13W/GX23,CFQ13W/GX231 CF-1320S-OC-TP %UL, cUL PH 2 A4120 0.26 16 > 0.50 < 20 0.901 CF-1320S-CC-TP UL, cUL PH 2 B41 CF-13-HP-TP 120 0.13 15 > 0.90 < 10 0.88 UL, cUL PH 3 C31 CF-13S-HP-TP + 120 0.13 15 > 0.90 < 10 0.88 UL, cUL PH 3 C71 CF-13-2-OC-TPUL, cUL PH 3 A3277 0.27 20 0.25 < 10 1.01 CF-13-2-CC-TP UL, cUL PH 3 D31 CF-13-2-HP-TP + 277 0.08 20 0.90 < 10 1.0 UL, cUL PH 3 D32 CF-213S-HP-TP 120 0.25 30 > 0.95 < 30 0.90 UL, cUL PH 18 D32 CF-213-2-TP 277 0.22 31 > 0.50 < 30 0.90 UL, cUL PH 24 D32 CF-213-2-HP-TP 277 0.12 31 > 0.95 < 25 0.90 UL, cUL PH 23 D3% Replace –OC by –WC for With Cord model+ Add –RJ for Recessed Downlight J-Box Mounting. See CASE HWS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


Magnetic Ballasts forCompact Fluorescent LampsMagneticBallastCompact LampsB11LampWattsLampType18 CFQ18W/G24d26 CFQ26W/G24d27 CFQ27W/GX32dNo. ofLampsCat.NumberInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 CF-118-1-TP 120 0.35 21 > 0.50 < 30 0.87 UL, cUL PH 3 C61 CF-118-1-HP-TP 120 0.18 21 > 0.95 < 30 0.87 UL, cUL PH 3 D11 CF-118-2-OC-TP 277 0.24 24 > 0.35 < 30 0.90 UL, cUL PH 2 A32 CF-218-1-HP-TP WS + 120 0.42 45 > 0.90 < 15 0.87 UL, cUL PH 23 C11 CF-126-1-TP 120 0.59 32 > 0.45 < 15 0.85 UL, cUL PH 3 D11 CF-126-1-HP-TP WS 120 0.28 32 > 0.95 < 30 0.89 UL, cUL PH 3 D11 CF-126-2-OC-TP 277 0.28 31 > 0.40 < 15 0.91 UL, cUL PH 2 A32 CF-226-1-HP-TP + 120 0.50 57 > 0.95 < 30 0.80 UL, cUL PH 23 C11 CF-128-OC-TPUL, cUL PH 2 A3120 0.53 29 > 0.45 < 25 0.901 CF-128-EN-TP UL, cUL PH 2 D31 CF-128-HP-TP 120 0.25 29 > 0.95 < 30 0.90 UL, cUL PH 3 D3WiringDia.DimensionsMagnetic Ballasts% Replace –OC by –WC for With Cord model+ Add –RJ for Recessed Downlight J-Box Mounting. See CASE HWS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


MagneticBallastMagnetic Ballasts forCompact Fluorescent LampsB12Circline LampsMagnetic BallastsLampWattsLampType20 FC6T9No. ofLampsCat.NumberInputVoltsInputCurrentInputWattsPowerFactorTHD%BallastFactorApprovalsStartingMethod1 CF-1322-OC-TPUL, CSA PH 7 A2120 0.30 16 > 0.45 < 15 0.731 CF-1322-CC-TP UL, CSA PH 7 B21 CF-22-WS-TP WS 120 0.35 21 > 0.5 < 20 0.79 UL, cUL PH 10 C7WiringDia.Dimensions1 CF-22-WS-TP WS 120 0.29 19 > 0.5 < 15 0.79 UL, cUL PH 10 C71 N-122-1-TP-WS 120 0.49 24 > 0.4 < 10 0.72 UL, cUL RS 10 D122 FC8T91 CF-1540-1-TP-IES WS 120 0.35 21 > 0.50 < 30 0.82 UL, cUL IES 19 C71 CF-1322-CC-TP 120 0.30 18 > 0.50 < 15 0.70 UL, cUL PH 7 B21 CF-1322-CC-PF 120 0.30 18 > 0.50 < 15 0.70 UL, cUL PH 7 B232 FC12T940 FC16T91 CF-1540-1-TP-IES WS 120 0.40 29 > 0.60 < 40 0.73 UL, cUL IES 19 C71 N-140-1-TP-WS WS 120 0.58 32 > 0.40 < 15 0.64 UL, cUL RS 10 D11 CF-1540-1-TP-IES WS 120 0.37 33 > 0.75 < 45 0.70 UL, cUL IES 19 C71 N-140-1-TP-WS WS 120 0.52 33 > 0.50 < 15 0.58 UL, cUL RS 10 D122&3232&40FC8T9 &FC12T9FC12T9 &FC16T92 N-2232-1-TP-WS 120 0.61 45 > 0.50 < 15 0.62 UL, cUL RS 11 C12 ES-3240-1-TP-WS WS 120 0.44 51 > 0.95 < 20 0.72 UL, cUL RS 11 C12 N-3240-1-TP-WS 120 0.55 63 > 0.95 < 25 0.69 UL, cUL RS 11 C12 ES-3240-1-TP-WS WS 120 0.56 66 > 0.95 < 25 0.72 UL, cUL RS 11 C1WS This item is well stock stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)


Magnetic BallastsMagneticBallastSign BallastsB13No. ofLampsLamp FootageMinMaxCat.NumberInputVolts/HzMax. Line Current(Amps)Max. InputPower(Watts)Open CircuitVoltsApprovalsWiring Dia.1,2 4 12 SB-0412-12-1-TP 120/60 1.48 175W 480V UL, cUL 5, 39 D8DimensionsMagnetic Ballasts2,3,4 6 20 SB-0620-24-1-TP 120/60 2.56 304W 600V UL, cUL 40, 41, 42 D82,3,4 12 24 SB-1224-24-1-TP 120/60 2.70 312W 785V UL, cUL 40, 41, 42 D92,3,4 20 40 SB-2040-24-1-TP 120/60 4.00 472W 720V UL, cUL 40, 41, 42 D104,5,6 12 40 SB-1240-46-1-TP 120/60 3.90 462W 720V UL, cUL 43, 44, 45 D104,5,6 24 48 SB-2448-46-1-TP 120/60 4.50 530W 720V UL, cUL 43, 44, 45 D10WS This item is well stockedFOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!