12.07.2015 Views

HP StorageWorks Ultrium Tape Blades

HP StorageWorks Ultrium Tape Blades

HP StorageWorks Ultrium Tape Blades

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

QuickSpecs<strong>HP</strong> <strong>StorageWorks</strong> <strong>Ultrium</strong> <strong>Tape</strong> <strong>Blades</strong>Enclosure ConfigurationFigure 1Installing a tape blade adjacent to a half-heightserver blade in a c7000 enclosure.Figure 2Installing a tape blade adjacent to a full-heightserver blade in a c7000 enclosure.<strong>HP</strong> <strong>StorageWorks</strong> <strong>Ultrium</strong> <strong>Tape</strong> <strong>Blades</strong>DescriptionQuantitySupportedPositionSupportedComments<strong>HP</strong> <strong>Ultrium</strong> <strong>Tape</strong> BladeNOTE: Connectedadjacent to a half-heightserver blade (Figure 1)Up to 8 per <strong>HP</strong>BladeSystem c-Class c7000EnclosureOdd or Evenslots next topartner serverbladeA tape blade supports one partner server blade, and onepartner server blade supports one tape blade.Identify the partner server blade to be installed with the<strong>HP</strong> tape blade. The two blades always occupy a pair ofslots, as follows: 1 & 2, 3 & 4, 5 & 6, 7 & 8, 9 & 10, 11 &12, 13 & 14, 15 & 16 (see Figure 1).If the partner server blade is installed in an oddnumberedbay, the <strong>HP</strong> tape blade is installed in theadjacent even-numbered bay to the right.If the partner server blade is installed in an evennumberedbay, the <strong>HP</strong> tape blade is installed in theadjacent odd-numbered bay to the left.<strong>HP</strong> <strong>Ultrium</strong> <strong>Tape</strong> BladeNOTE: Connectedadjacent to a full-heightserver blade (Figure 2)Up to 4 per <strong>HP</strong>BladeSystem c-Class c7000EnclosureOdd or evenslots next topartner serverblade (lowerbays only)A tape blade supports one partner server blade, and onepartner server blade supports one tape blade.When partnering a tape blade with a full height serverblade, an <strong>HP</strong> PCI Express Mezzanine Pass-Thru Cardfor BladeSystem c-Class (431643-B21) is required. Thiscard is installed in mezzanine 3 connector in the serverblade.Identify the partner server blade to be installed with the<strong>HP</strong> tape blade. The two blades always occupy a pair ofslots, as follows: 9 & 10, 11 & 12, 13 & 14, 15 & 16 (seeFigure 2).If the partner server blade is installed in an oddnumberedbay, the tape blade is installed in the adjacenteven-numbered bay to the right.DA - 12729 Worldwide QuickSpecs — Version 10 — 4/3/2009 Page 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!