12.07.2015 Views

143 XT IEC Power Control Manual Motor Protectors - Westburne

143 XT IEC Power Control Manual Motor Protectors - Westburne

143 XT IEC Power Control Manual Motor Protectors - Westburne

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

138<strong>XT</strong> <strong>IEC</strong> <strong>Power</strong> <strong>Control</strong><strong>Manual</strong> <strong>Motor</strong> <strong>Protectors</strong>Product Family OverviewMay 2007ContentsDescriptionPageCatalog NumberSelection . . . . . . . . . . . . . . . . 141Product Selection . . . . . . . . . . 142Accessories . . . . . . . . . . . . . . . 147Technical Data andSpecifications . . . . . . . . . . . . 159Dimensions . . . . . . . . . . . . . . . 167Reference Data . . . . . . . . . . . . . 199B-FramePushbuttonB-FrameRotaryProduct DescriptionD-FrameEaton’s new <strong>XT</strong> family of <strong>Manual</strong><strong>Motor</strong> <strong>Protectors</strong> (MMPs) features apushbutton or rotary ON/OFF manualdisconnect, Class 10 adjustablebimetallic overload relay and fixedmagnetic short circuit trip capability inone compact unit. Two frame sizesare available: Frame B (45 mm) formotors with FLA ratings up to 32Aand Frame D (55 mm) covers motorFLA ratings up to 63A.Application DescriptionThe <strong>XT</strong>PB and <strong>XT</strong>PR MMPs can beused in the following applications.<strong>Motor</strong> Protective Circuit BreakerIn many countries outside of theUnited States and Canada, especiallyEurope, the MMPs are tested andclassified as thermal magnetic circuitbreakers for use in motor branchcircuits. This can be an importantconsideration for all companies whoexport their equipment and machinesinternationally. Both the <strong>XT</strong>PB and<strong>XT</strong>PR conform to <strong>IEC</strong>/EN 60947 andhave the CE Mark.<strong>Manual</strong> <strong>Motor</strong> <strong>Protectors</strong>The <strong>XT</strong>PB and <strong>XT</strong>PR MMPs are UL Listedunder UL 508 as <strong>Manual</strong> <strong>Motor</strong> <strong>Protectors</strong>.They provide an economical solutionfor applications requiring simplemanual starting and stopping of motors.When used as an MMP, they are typicallyinstalled in an enclosure. Many enclosuresare offered as accessories for theMMPs. Separate short-circuit protectivedevices, such as circuit breakers orfuses, are wired ahead of the MMPs. Theshort-circuit protective device should besized per the NEC code and should notexceed 400% of the maximum FLA dialsetting of the MMP.Group <strong>Motor</strong> InstallationsA Group <strong>Motor</strong> Installation can bedefined as more than one motor circuitprotected by a single set of fuses or circuitbreaker on a motor branch circuit.This eliminates the need for individualfuses or circuit breakers for eachmotor circuit. Substantial componentcost savings, panel space savings andreduced wiring installation time can beachieved in Group <strong>Motor</strong> Installations.The MMPs are tested and listed forgroup installation. If remote operationis required, a magnetic contactor canbe wired in series with the MMP. SeeFigure 98.Article 430.53 of the National ElectricCode contains the rules and requirementsfor Group <strong>Motor</strong> Installations.Refer to Application Note AP03402001Efor NEC requirement for group motorinstallation.To Supply<strong>XT</strong>PRDisconnectFuses<strong>XT</strong>PR<strong>XT</strong>PROr CircuitBreaker<strong>Manual</strong><strong>Motor</strong>ProtectorMagnetic Contactor(Used forRemote <strong>Control</strong>)<strong>Motor</strong>sFigure 98. Group <strong>Motor</strong> InstallationNEC 430-53See Application Note — AP03402001E.Protection in Different <strong>Control</strong>lerTypesA UL 508 Type E Self-protected <strong>Manual</strong>Combination Starter/<strong>Motor</strong> <strong>Control</strong>lerconsists of a single device having integralshort circuit protection, a main setof contacts, motor overload protection,and may also include a UL listed LineSide Adapter (see Figure 99). This typeof controller is a legitimate short circuitprotective device and disconnectmeans for the downstream motor. Itdoes require an upstream feeder shortcircuit protective device, but does notrequire a dedicated branch circuit protectionor a disconnect means. A UL508 Type E rating means that the unitclears a fault and does not experienceany welding of the power poles. A UL508 Type E self-protected manual combinationstarter will remain fully functionalshould a short circuit within itsratings occur.A UL 508 Type F Self-protected Combination<strong>Motor</strong> <strong>Control</strong>ler consists of aUL 508 Listed Type E Self-protected<strong>Manual</strong> Combination Starter/<strong>Motor</strong><strong>Control</strong>ler, a UL Listed Contactor, andpossibly a UL Listed Line Side Adapter.While the Type E self-protected manualmotor controller of this combinationmotor controller device is a legitimateshort circuit protective device anddisconnect means for the downstreammotor, the contactor is not“self-protected.” E.g. <strong>XT</strong>CE007 –<strong>XT</strong>CE065.In addition, as a complete assembly ormodular components, the device shouldhave Type 2 Coordination certification.Type 2 Coordination means the Starter orthe <strong>Control</strong>ler must exhibit little or no damagefollowing a major short circuit faultand should be able to be returned to properservice without replacing any parts.Component in a Combination<strong>Motor</strong> <strong>Control</strong>lerThe <strong>XT</strong>PB and <strong>XT</strong>PR MMPs can also bewired in series with a magnetic contactorto complete the assembly of aremotely operated, combination motorcontroller.For more information visit: www.eaton.comCA03407001E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!