12.07.2015 Views

exigo eostechnical specification v3.indd

exigo eostechnical specification v3.indd

exigo eostechnical specification v3.indd

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Automatic Hematology Analyzer for veterinary useKey features-Full automatic system with 19 or 17 parameters.-Multiple species with programmable analysis profiles. (*)-Built-in Mixer for 6 tubes of 3 different sizes.-Open tube inlet or direct start with a 20ul microcapillary.-7” Color touch screen with self intuitive operation.-Advanced Veterinary WBC diff. (*)-Hematological Guidelines for pathological samples. (*)-On board clot prevention system.(*)-Control Assay Values scanned into system through barcodeentry. (*)-Capacity up to 60 samples per hour.-USB, Centronics and RS232 output.-Connector for external PC keyboard.(*) see description belowAnalyzer description& featuresArt no Article name1400061 Exigo, 17 parameters1400076 Exigo eos, 19 parametersAnalysis profilesExigo comes with pre-installed animal analysis profiles and thepossiblity to develop your own species profiles. Pre-installed:Dog, Cat, Horse, Cow, Ferret, Rabbit, Sheep, Rat, Mouse, Pig,New World Camel and Goat. New profiles for other species areavailable as product updates. Up to 20 animal profiles can beused in the instrument at the same time.Available parametersUsing impedance method:-WBC, LYMa, LYM%, MONOa, MONO%, GRANa, GRAN%-NEUTa*, NEUT%*, EOSa*, EOS%*-RBC, MCV,-PLT, MPVUsing photometric method (cyanide free):-HGBCalculated parameters-HCT, MCH, MCHC, RDWa, RDW%* Available on Exigo eos onlyOperation modesOpen tubes with EDTA blood.EDTA coated 20μl micro capillaries.Advanced WBC diff methodA WBC differential from animal blood is one of the more difficultparameters to measure. By using an advanced analysis algorithm,Exigo takes into consideration both the actual measuredcell compositions as well as what is expected form the analyzedspecies, when performing the analysis. Every profile usesa dynamic approach on how to analyze the sample for the mostaccurate result.Hematological guidelines by ExigoSamples considered as pathological will be flagged by thesystem and will give a clear recommended action for furtheranalysis of the sample.Recommended cleanersExigo should be cleaned periodically to avoid build up of proteinsor bacterial growth inside the system. Use only original cleaners.Other cleaners may damage the interior of the system.Art No Article name1504126 Boule Hypochlorite CleanerUsed for Manual clot removal procedure.1504111 Boule Cleaning KitUsed for periodic maintenance.On-board clot prevention systemAnimal blood specimens have a tendency to cause clots andblockages in cell-counter analysis systems. Therefore Exigo isequipped with on-board cleaner, automatically keeping thesystem clean.ReagentsExigo should only be used with its original reagents. All reagentsare non-toxic and cyanide-free.Art No Article name1504201 Exigo Diluent 1,9 L1504202 Exigo Lyse 1,9 L .1504203 Exigo System Cleaner 1,9 LAdditional Reagents for Exigo eosArt No Article name1504278 Exigo EOS Reagent 1,9 L1504328 Exigo Diluent 10 LSystem VerificationEvery veterinarian should be able to trust and depend upontheir analyzer, which is why a full QC system has been designedinto the Exigo software. And, by using barcodes for handlingand registering the controls and their assay values, it is simple touse, effortless and 100% secure.Control samplesControl samples should be used on a frequent (preferably daily)basis to verify the systems operation. Using the system Controlfrequently gives clear and quality proof of the system’s mance, which can easily be monitored through the built-in QCperforprogram.Art No Article name Description1504026 Boule Vet Con 1*4.5ml1504027 Boule Vet Con 6*4.5mlCalibratorCalibrators should be used for the calibration procedure whichis typically made upon installation, after service or after periodicmaintenance.Art No Article name Description1504028 Boule Vet Calibrator 1*3mlClinical dataCorrelation for veterinary samples is very dependent on thehematological composition of the blood from the species beinganalyzed, as well as sampling methodology and pre-analytichandling. The below correlation data is based on Boule controlblood.Precision and Measuring RangeRBC MCV HGB WBC PLTRange 0-14.0 x 10 6 /µl 15-250 fl 0-99.9 g/dl 0-99.9 x 10 3 /µl 0-1999 x 10 3 /µlCV% ≤1.1% ≤0.3% ≤1.0% ≤1.9% ≤3.5%*Typical values over 10 consecutive measured Boule Control samples by open tube mode and undergood laboratory conditions.Carry OverRBC HGB WBC PLTOpen Tube ≤2 % ≤1 % ≤1 % ≤2 %MPA ≤2 % ≤2 % ≤2 % ≤3.5 %

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!