12.07.2015 Views

Buoyancy Compensators manual - Scubapro

Buoyancy Compensators manual - Scubapro

Buoyancy Compensators manual - Scubapro

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Deflating the BC with the Manual Dump ValveStop and assume an upright position in thewater. When in position, open the ManualDump Valve by gently pulling downward onthe Oral Valve/Power Inflation Valve Assembly(fig. 7 - A). It is not necessary to use excessivepressure to pull on the hose assembly. Valvetravel is limited and pulling harder will notincrease the air flow. To close the ManualDump Valve, stop pulling downward, andrelease.ALCB! WARNINGKeep sand and other contamination out of the Oral Valve mouthpiece and valvebutton. Under certain conditions, contamination can cause the valve to not closecompletely. If this occurs while diving, shake the valve while depressing it severaltimes. If the valve leaks or remains inoperable, terminate the dive. Diving with aleaking <strong>Buoyancy</strong> Compensator or with valves that do not operate properly mayresult in a loss of buoyancy control that could result in injury or death.Deflating the BC with the Oral Valve (BPI and /or AIR 2)Assume a head up position in the water. Raise the Oral Valve above and in front of your face.(This insures the Oral valve will be positioned above the air bubble in the BC.). Depress theOral Valve button and visually confirm that air is escaping from the mouthpiece. For bestcontrol, let air out in a series of short, measured amounts while observing the effects onyour buoyancy.! WARNING• The SCUBAPRO ® Dual Manual Dump Valve (Patent) has a safety hand buttonthat releases air when pushed (fig 7-C) , in case of failure of the Manual DumpSystem (broken cable, pin, etc.) or while breathing from an Air 2.• With all deflation methods, hold the valve open no longer than needed. Thishelps prevent excess water from entering the BC.• Do not depress the Oral Valve button when activating the Manual Dumpvalve, as water may enter the BC through the Oral Valve mouthpiece.Over Pressure Valve OperationThe Over Pressure Valve prevents over-inflation of the BC. If the internal pressure exceedsthe spring pressure in the Over Pressure Valve, the valve automatically opens and releases airto prevent damage to the BC. The valve will automatically close when the internal pressuregoes below the spring pressure in the Over pressure Valve.fig. 710

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!