12.07.2015 Views

Conductivity Transmitter - Ebora

Conductivity Transmitter - Ebora

Conductivity Transmitter - Ebora

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Conductivity</strong> <strong>Transmitter</strong>- Type Condutec -INSTALLATION NOTES• The Condutec is delivered with the standard parameter setting. Please make sure that the instrument ischanged to the applications before it will be used. Simulation of the temperature and conductivity in manualoperation is possible.• Temperature compensation:Good measurement results can only be achieved by using the temperature compensation. Please study theoperating manual for details .• Adjusting the cell constant:The exact cell constant C is marked on all 4-electrode conductivity cells. This cell constant must be taken intoaccount when setting the parameters (see operating manual). Due to aging processes the cell constant may bechanged. In order to determine the correct cell constant the cell has to be dipped into a reference solution whilecarefully stirring. Various reference solutions are available. The reference solution chosen, should correspondto the measurement range the equipment is operating in.• Mounting:- When installing conductivity measurement, please make sure that there is no air at the active area of theconductivity cells!- Take care that there is adequate flow through and around the sensors.- If the devices are mounted in pipes, please make sure that the required distance between sensor and wallof the pipe are guaranteed. Otherwise the compensation of the cell has to be changed!- The fixing of the sensors must be secure and free of vibrations!- When installing a system with Condutec compact unit, it may be necessary to turn converter undconductivity cell against each other for easy operation and better reading of the display. These assemblyvariations are possible in steps of 30°.• <strong>Conductivity</strong> cells LF 3533 und LF 4533 (VARIVENT):The sensor may not be installed with other instruments in 1 VARIVENT-housing!• <strong>Conductivity</strong> cells LF 3733 und LF 4733 (milk sanitary):The cell constant must be changed in case that the distance between wall of pipe and sensor is too small!Please read the operating manual before commissioning the instrument.Our products are constantly in further development, therefore subjects to modifications.A/Condutec/D-e-08-1/8Hengesbach GmbH & Co. KG · Schimmelbuschstr. 17 · D-40699 Erkrath · Tel. +49 (0) 21 04 / 30 32-0 · Fax +49 (0) 21 04 / 30 32-22 · www.hengesbach.biz

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!