12.07.2015 Views

AutoCross-Laser ACL 4C / ACL 4C RX - Spot-on.net

AutoCross-Laser ACL 4C / ACL 4C RX - Spot-on.net

AutoCross-Laser ACL 4C / ACL 4C RX - Spot-on.net

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>AutoCross</str<strong>on</strong>g>-<str<strong>on</strong>g>Laser</str<strong>on</strong>g> <str<strong>on</strong>g>ACL</str<strong>on</strong>g> <str<strong>on</strong>g>4C</str<strong>on</strong>g> / <str<strong>on</strong>g>ACL</str<strong>on</strong>g> <str<strong>on</strong>g>4C</str<strong>on</strong>g> <str<strong>on</strong>g>RX</str<strong>on</strong>g>Preparing the calibrati<strong>on</strong> check:It is possible for you to check the calibrati<strong>on</strong> of the laser. To do this, positi<strong>on</strong>the device midway between 2 walls, which must be at least 5 metres apart.Switch the device <strong>on</strong> (<str<strong>on</strong>g>Laser</str<strong>on</strong>g> cross ON). The best calibrati<strong>on</strong> results are achievedif the device is mounted <strong>on</strong> a tripod. 1. Mark point A1 <strong>on</strong> the wall.2. Turn the device1.through 180° andA1mark point A2.You now have a2.horiz<strong>on</strong>tal referenceA2 between points A1and A2.Performing the calibrati<strong>on</strong> check:3. Positi<strong>on</strong> the device as near as possible to the wall at the height of3.A1A2A2point A1.4. Turn the devicethrough 180° andmark point A3. The4.A3difference betweenA2 points A2 and A3 isA3 the tolerance.Note: If points A2 and A3 are imore than 2 mm / 10 m, the device is inneed of calibrati<strong>on</strong>. C<strong>on</strong>tact your authorised dealer or else the UMAREX-LASERLINER Service Department.Checking the vertical line: Positi<strong>on</strong> the device about 5 m from a wall. Fix aplumb bob with a line of 2.5 m length <strong>on</strong> the wall, making sure that the bobcan swing freely. Switch <strong>on</strong> the device and align the vertical laser to the plumbline. The precisi<strong>on</strong> is within the specified tolerance if the deviati<strong>on</strong> between thelaser line and the plumb line is not greater than ± 1.5 mm.Checking the horiz<strong>on</strong>tal line:2,5 mPositi<strong>on</strong> the device about 5 m from a wall andswitch <strong>on</strong> the cross laser. Mark point B <strong>on</strong> the wall. BCTurn the laser cross approx. 2.5 m to the right andmark point C. Check whether the horiz<strong>on</strong>tal linefrom point C is level with point B to within ± 2 mm. Repeat the process byturning the laser to the left.14< 2 mm / 10 m = OKenglish< 2 mm = OK

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!