Ama -Drainer - Anchor Pumps
Ama -Drainer - Anchor Pumps
Ama -Drainer - Anchor Pumps
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Ama</strong>-<strong>Drainer</strong><strong>Ama</strong>-<strong>Drainer</strong> 324, 356/358n = 2800 1/minfree passage324 = 24 mm356 = 35 mm358 = 35 mm<strong>Ama</strong>-<strong>Drainer</strong> ISO 7/1 Rp Particle size P 1 P 2 1~230 V Power supply cablenetH 07 RN-F.G.max. mm kW kW ≈A m mm 2 kg324 SE/NE 1 ) 1 1 / 4 24 0.6 0.4 2.8 10 3 x 1.0 40 984 251 6.7356 SE/NE 1 ) 1 1 / 2 35 0.6 0.3 2.8 10 3 x 1.0 40 982 123 7.1358 SE/NE 1 ) 1 1 / 2 35 0.8 0.4 3.6 10 3 x 1.0 40 982 124 7.11 ) Attention! For external control or duplex pump sets the float switch must be replaced by the locking disc supplied.2