13.07.2015 Views

FXV BROCHURE.pdf - Emerson Swan

FXV BROCHURE.pdf - Emerson Swan

FXV BROCHURE.pdf - Emerson Swan

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

• Optional Stainless Steel Coil:Coils are available in Type 304 stainless steel for specialized applications. The coil is designed forlow pressure drop with sloping tubes for free drainage of fluid. Each coil is pneumatically tested at375 psig (2586 kPa) and is ASME B31.5 compliant.• Optional Straight-Through Cleanable Coil: (Available on Single Air Inlet Models)A header box with a removable cover plate at each end of the coil allows access to every tube end formechanical cleaning or plugging. It is available in carbon steel (hot-dip galvanized inside and out) orstainless steel. Each coil is pneumatically tested at 125 psig (860 kPa).• Optional ASME “U” Stamp Coil:The ASME coils are requested for heavy industrial or process applications. This serpentine coil ismanufactured and tested in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII,Division 1, and bears the ASME “U” stamp. ASME coils are hot-dip galvanized (outside surface) afterfabrication (HDGAF). The coil is designed for low pressure drop with sloping tubes for free drainage offluid. Each coil is pneumatically tested at 375 psig (2586 kPa).When required, coils shipping into Canada are supplied with a CRN. Other coil configurations areavailable for specific applications. Contact your local BAC Representative for details.Fan Drive SystemThe fan drive system provides the cooling air necessary to reject unwanted heat from the system to theatmosphere. The standard fan drive system on all models is the BALTIDRIVE ® Power Train. This BACengineered drive system consists of a specially designed powerband and cast aluminum sheaveslocated on minimum shaft centerline distances to maximize belt life. A premium efficient fan motorprovides maximum performance and is backed by BAC’s comprehensive 5-year motor and fan drivewarranty.Closed Circuit Cooling TowersBALTIGUARD Fan SystemThe BALTIGUARD Fan System consists of two standard single-speed fan motors and driveassemblies. One drive assembly is sized for full speed and load, and the other is sized forapproximately 2/3 speed and consumes only 1/3 the design horsepower. This configuration allows thereserve capacity of a standby motor in the event of failure. As a minimum, approximately 70% capacitywill be available from the low horsepower motor, even on a design wet-bulb day. Controls and wiring arethe same as those required for a two-speed, two-winding motor. On some units the standby fan motorcan be increased to the size of the main motor for 100% redundancy.BALTIGUARD PLUS TM Fan SystemThe BALTIGUARD PLUS TM Fan System builds on the advantages of the BALTIGUARD Fan System byadding a VFD to one of the motors. For more information on the BALTIGUARD PLUS TM Fan Systemrefer to page K1....because temperature matters E20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!