13. Timing between rotating hook motion and needle motion1)Set feed length (stitch length) to “6” on thefeed setting dial.2)When needle is lifted 2.4mm from the lowerdead point, as shown in Figure, thefollowing positional relationship shouldbe maintained.· The upper edge of needle eye should be2.3 mm below the hook point.· The hook point should be located at thecenter of needle axis.· Gap between the hook point and the sideface of needle should be 0.0.5mm.14. Relationship between hook motion and opener motion1)Turn the balance wheel by hand and stopwhen the opener holder is located mostremotely from the throat plate.2) Make sure gap between the bobbin caseholder A and the opener is approximately0.2 mm.3) If the gap is too large or small , loosen theopener holder set screw B and adjustposition of the opener.15. Relationship between needle motion and feed dog motion1)Set feed length to “0” on the feed setting dial2) Set the needle at the lowest position.3)Lean the machine head backward, remove the back cover, loosen screw B and C.4)Adjust the distance between presser rod and vibration prevention rod to 9 mm.5)After the completion of adjustment, fully tighten the screws B and C.Note:At this time makecertain that needle canenter the feed dog needlehole at the center of thehole.— 7 —