13.07.2015 Views

IPS e.max Press Abut..

IPS e.max Press Abut..

IPS e.max Press Abut..

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

®<strong>Press</strong> <strong>Abut</strong>ment SolutionsEfficiency and esthetics redefinedall ceramicall you need


More press ceramic options ...<strong>Press</strong> ceramics have been synonymous with the ideal combinationof accuracy of fit, shape and function for decades. Inaddition, the <strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> lithium disilicate glass-ceramic(LS 2 ) offers an outstanding strength of 400 MPa.The already extensive indication range – from thin veneers(0.3 mm) and monolithic crowns to anterior and premolarbridges – has now been expanded to include hybridabutment restorations.With <strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong>, you can fabricate such restorationsin combination with a titanium base (Ti base). Two differentapproaches are available for this purpose:• hybrid abutments and• hybrid abutment crowns.Both solutions show outstanding function, efficiency andesthetics. The durable bond to the Ti base is achieved bymeans of the self-curing Multilink ® Implant luting composite.<strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> <strong>Abut</strong>ment Solutions are an integral partof the "Competence in Implant Esthetics" concept ofIvoclar Vivadent.


... thanks to hybrid abutment restorationshigh estheticsefficiencystrong bondThe adequate solution for every caseGenerally, pressed abutment restorations can be fabricatedin two ways:• Efficient and supremely estheticIn this case, fabricating a customized, tooth-colouredhybrid abutment and subsequently an <strong>IPS</strong> e.<strong>max</strong> all-ceramiccrown is the right choice. The final outcome features aharmonious, highly esthetic appearance – due to the lifelikeshade design of both the abutment and the transition areato the crown.• Supremely efficient and estheticTo meet these requirements, the two-in-one option isrecommended: a hybrid abutment crown, which combinesthe abutment and the monolithic crown in one piece. Thus,innovative implant-supported restorations are fabricatedhighly efficiently. Intraoral cementation and the bothersomeremoval of excess material are a thing of the past.The highlightsHybrid abutment<strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> LS 2Ti baseHybrid abutment crown<strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> LS 2Ti base• <strong>Press</strong>ed hybrid abutment solutions from your laboratory• High, lasting esthetics, also in cases of gingiva recession, thanks to tooth-coloured hybrid abutments• Hybrid abutment crowns (two-in-one) for function, efficiency and access to the screw at any time• Excellent bond strength between LS 2 and the Ti base due to Multilink Implant


Hybrid abutments for <strong>max</strong>imum estheticsHybrid abutments are individually pressed LS 2 abutmentswhich are luted to a Ti base. The shape, emergence profileand esthetic properties of such abutments can be ideallyadjusted to the clinical situation.Individualized estheticsWith LS 2 glass-ceramics, the esthetic possibilities are virtuallylimitless, particularly in the anterior region. Giventhe material's fluorescence in conjunction with individualcharacterizations, a lifelike appearance is achieved near theroot and the transition area to the crown. With the preparationmargin of the crown located on the gingiva level,the geometry of the hybrid abutment allows for an easyintegration of the restoration. Excess cementation materialcan thus be easily removed.cavity and finally provided with a permanent <strong>IPS</strong> e.<strong>max</strong>crown. As the hybrid abutment is conveniently fabricated inthe lab, the process is time-saving and flexible.New possibilities for high-quality restorations<strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> hybrid abutments are a new alternativeto prefabricated or customized abutments made of othermaterials. This innovative solution is ideally suitable fordurable, highly esthetic restorations also in patients whosuffer from gingiva recession.Flexibility due to laboratory fabricationThe pressed LS 2 abutment is extraorally luted to a Ti basewith Multilink Implant, then screwed into place in the oralInitial situation prior to the implantation Contoured emergence profile <strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> hybrid abutmentand <strong>IPS</strong> e.<strong>max</strong> crownRonny Watzke, Ivoclar Vivadent, LiechtensteinScrewed-in hybrid abutmentCrown luted to hybrid abutment


Creating optimized emergence profiles„I have been successfully using lithium disilicateon titanium abutments for some years now.This material allows me to create an optimizedemergence profile quickly and easily, and thiscontributes to the beautiful appearance of my<strong>IPS</strong> e.<strong>max</strong> all-ceramic restorations.”Christian Coachman, dentist anddental technician, Brazil


Biocompatibility and ideal bondGood biocompatibilityAn optimum biocompatibility is decisive for a durable andsuccessful material used in conjunction with abutmentsand implant-supported restorations. Numerous studiescarried out over many years confirm the good biocompatibilityof <strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> (LS 2 ) glass-ceramic with the oralsoft tissue.Cementation: an integral part of the processThe results of bond strength tests confirm the high qualityof the adhesive bond between <strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> (LS 2 ) andTi bases. The quality of the bond is not compromised if<strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> restorations are sterilized according to therespective guidelines, as impressively shown by the comparisonof non-sterilized and sterilized test specimens.Ronny Watzke, Ivoclar Vivadent, Liechtenstein"[…] regarding the periodontal parameters, no significantdifferences (P > 0.05, Wilcoxon rank sum test) were foundwhen pocket depth, bleeding on probing and tooth mobilitywere compared between test and control teeth."S. Wolfart, S. Eschbach, S. Scherrer, M. Kern (2009). "Clinical outcome ofthree-unit lithium-disilicate glass-ceramic fixed dental prostheses: up to8 years results." Dental Materials 25(9).40.0Shear bond strength of LS 2 on Tinon-sterilized vs sterilized specimensShear bond strength in MPa35.030.025.020.015.010.05.00.0<strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong><strong>IPS</strong> e.<strong>max</strong> <strong>Press</strong> (sterilized specimens)Source: R&D Ivoclar Vivadent, Liechtenstein, 2011


Seating and aftercare<strong>IPS</strong> e.<strong>max</strong> ® <strong>Abut</strong>ment Solutions CEM KitThe <strong>IPS</strong> e.<strong>max</strong> <strong>Abut</strong>ment Solutions Cementation Kit offersan ideally coordinated range of products for the cementationof hybrid abutments made of LS 2 and ZrO 2 to Ti bases.It contains all the components that are required to prepareand perform a clinical try-in (e.g. Virtual ® Extra LightBody Fast Set) and all the materials that are needed topermanently cement restorations to Ti bases (e.g. MultilinkImplant). The self-curing luting composite Multilink Implanthas been specifically developed for the permanent cementationof implant-supported restorations. In conjunctionwith the Monobond ® Plus primer, this material yieldsexcellent bonding values.Implant Care ProgramImplant Care comprises a coordinated range of products forthe professional care of patients during the different phasesof an implant treatment and the lifelong aftercare.Products for professional cleaning (e.g. Proxyt ® ) and bacteriacontrol (e.g. Cervitec ® ) contribute to maintaining the qualityof implant-retained restorations in the long-term. As aresult, implant-supported restorations made of <strong>IPS</strong> e.<strong>max</strong><strong>Press</strong> are treated and maintained in an optimum fashion,with regard to both function and esthetics.


®<strong>Press</strong> <strong>Abut</strong>ment Solutionsall ceramicall you needThis product forms part of ourAll-Ceramics and Implant Estheticscompetence areas. All the productsof these areas are optimallycoordinated with each other.Ivoclar Vivadent AGBendererstr. 2FL-9494 SchaanPrincipality of LiechtensteinTel. +423 / 235 35 35Fax +423 / 235 33 60www.ivoclarvivadent.comDescriptions and data constitute no warranty of attributes.Printed in Germany© Ivoclar Vivadent AG, Schaan / Liechtenstein639649/1211/e/W

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!