13.07.2015 Views

Why LG Multi Split System?

Why LG Multi Split System?

Why LG Multi Split System?

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>LG</strong> Air Conditioners 2009<strong>Multi</strong> <strong>Split</strong> <strong>System</strong>Combination Table88 89<strong>Multi</strong> <strong>Split</strong> <strong>System</strong>Combination TableFM48AH U33FM48AH U33FM56AH U33FM56AH U33Total Indoor UnitCapacity(kBtu/h)Cooling CapacityInput(W)Total Indoor UnitCapacity(kBtu/h)Heating CapacityInput(W)Total Indoor UnitCapacity(kBtu/h)Cooling CapacityInput(W)Total Indoor UnitCapacity(kBtu/h)Heating CapacityInput(W)1920212223242526272829303132333435363738394041424344454647484950515253545556575859606162Btu/h11,40012,00012,60013,20013,80014,40015,00015,60016,20016,80017,40018,00018,60019,20019,80020,40021,00021,60022,20022,80023,40024,00024,60025,20025,80026,40027,00027,60028,20028,80029,40030,00030,60031,20031,80032,40033,00033,60034,20034,80035,40036,00036,60037,200Min Rating MaxkW3.33.53.73.94.04.24.44.64.74.95.15.35.55.65.86.06.26.36.56.76.97.07.27.47.67.77.98.18.38.48.68.89.09.19.39.59.79.810.010.210.410.510.710.9Btu/h19,00020,00021,00022,00023,00024,00025,00026,00027,00028,00029,00030,00031,00032,00033,00034,00035,00036,00037,00038,00039,00040,00041,00042,00043,00044,00045,00046,00047,00048,00048,34348,68649,02949,37249,71550,05850,40150,74451,08751,43051,77352,11652,45952,800kW5.65.96.26.46.77.07.37.67.98.28.58.89.19.49.710.010.310.510.811.111.411.712.012.312.612.913.213.513.814.114.214.314.414.514.614.714.814.915.015.115.215.315.415.5Btu/h20,90022,00023,10024,20025,30026,40027,50028,56029,61030,67031,72032,78033,83034,89035,94037,00038,05039,60040,70041,80042,90044,00046,10046,85047,59048,34049,08049,83050,57052,80053,17753,55453,93154,30854,68555,06255,43955,81656,19356,57056,94757,32457,70158,080kW6.16.46.87.17.47.78.18.48.79.09.39.69.910.210.510.811.211.611.912.212.612.913.513.713.914.214.414.614.815.515.615.715.815.916.016.116.216.416.516.616.716.816.917.0Note :1.Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB; outdoor temp. 35°C DB2.Heating Capacity is based on : indoor temp.20°C DB; outdoor temp. 7°C DB, 6°C WB3.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant.Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.4.Total capacity index of indoor unit should be within 19~62k Btu/h(40%~130%)5.At least two indoor units should be connected.Min8418839269681,0111,0531,0961,1611,2271,2921,3571,4231,4881,5541,6191,6851,7501,8161,8591,9031,9471,9912,0352,1212,2082,2952,3812,4682,5542,7122,7122,7202,7282,7352,7432,7512,7592,7672,7742,7822,7902,7982,8062,813Rated1,4011,4721,5431,6141,6841,7551,8261,9352,0442,1532,2622,3722,4812,5902,6992,8082,9173,0263,0993,1723,2453,3183,3913,5363,6803,8243,9694,1134,2574,5204,5204,5334,5464,5594,5724,5854,5984,6114,6244,6374,6504,6634,6764,689Max1,6111,6931,7741,8561,9372,0192,1002,2252,3512,4762,6022,7272,8532,9783,1043,2293,3553,4803,5643,6483,7323,8163,9004,0664,2324,3984,5644,7304,8965,0625,0625,0775,0775,1065,1215,1355,1505,1645,1795,3505,3505,3505,3505,3501920212223242526272829303132333435363738394041424344454647484950515253545556575859606162Btu/h12,76813,44014,11214,78415,45616,12816,80017,47218,14418,81619,48820,16020,83221,50422,17622,84823,52024,19224,86425,53626,20826,88027,55228,22428,89629,56830,24030,91231,58428,80029,40030,00030,60031,20031,80032,40033,00033,60034,20034,80035,40036,00036,60037,200Min Rating MaxkW3.73.94.14.34.54.74.95.15.35.55.75.96.16.36.56.76.97.17.37.57.77.98.18.38.58.78.99.19.38.48.68.89.09.19.39.59.79.810.010.210.410.510.710.9Btu/h2128022400235202464025760268802800029120302403136032480336003472035840369603808039200403204144042560436804480045920470404816049280504005152052640540005414354286544295457254715548585500155144552875543055573557165585956000kW6.26.66.97.27.57.98.28.58.99.29.59.810.210.510.811.211.511.812.112.512.813.113.513.814.114.414.815.115.415.815.915.915.916.016.016.116.116.216.216.216.316.316.416.4Btu/h2289724014251312624927366284832960030869321383340734676359453721538484397534102242291435604464845736468244791249000504845196853452549365642057904560005621456428566425685657070572845749857712579265814058354585685878259000kW6.77.07.47.78.08.38.79.09.49.810.210.510.911.311.612.012.412.813.113.413.714.014.414.815.215.716.116.517.016.416.516.516.616.716.716.816.816.917.017.017.117.217.217.3Min1,3011,3501,3991,4481,4971,5461,6431,6961,7481,8001,8521,9041,9572,0092,0612,1132,1652,2172,2642,3062,3472,3862,4522,4732,5082,5442,5792,6142,6502,6852,7202,7562,7912,8262,8472,9112,9222,7362,7362,7362,7362,7392,6552,658Rated2,1682,2502,3322,4132,4952,5762,7392,8262,9133,0003,0873,1743,2613,3483,4353,5223,6093,6963,7743,8433,9113,9774,0874,1224,1814,2394,2984,3574,4164,4754,5344,5934,6524,7104,7454,8524,8704,5604,5604,5604,5604,5654,4254,430Max2,4942,5882,6812,7752,8692,9633,1503,2503,3503,4503,5503,6503,7503,8503,9504,0504,1504,2504,3404,4204,4984,5734,7004,7404,8084,8754,9435,0115,0785,1465,2145,2825,3495,4175,4575,5805,6005,4005,3405,3405,3405,3405,3405,340232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273Min Rating MaxBtu/h13,80014,40015,00015,60016,20016,80017,40018,00018,60019,20019,80020,40021,00021,60022,20022,80023,40024,00024,60025,20025,80026,40027,00027,60028,20028,80029,40030,00030,60031,20031,80032,40033,00033,60034,20034,80035,40036,00036,60037,20037,80038,40039,00039,60040,20040,80041,40042,00042,60043,20043,800kW4.04.24.44.64.74.95.15.35.55.65.86.06.26.36.56.76.97.07.27.47.67.77.98.18.38.48.68.89.09.19.39.59.79.810.010.210.410.510.710.911.111.311.411.611.812.012.112.312.512.712.8Btu/h23,00024,00025,00026,00027,00028,00029,00030,00031,00032,00033,00034,00035,00036,00037,00038,00039,00040,00041,00042,00043,00044,00045,00046,00047,00048,00048,62549,25049,87550,50051,12551,75052,37553,00053,23653,47253,70853,94454,18054,41654,65254,88855,12455,36055,59655,83256,06856,30456,54056,77657,012kW6.77.07.37.67.98.28.58.89.19.49.710.010.310.510.811.111.411.712.012.312.612.913.213.513.814.114.214.414.614.815.015.215.315.515.615.715.715.815.915.916.016.116.216.216.316.416.416.516.616.616.7Btu/h25,30026,40028,00029,06030,11031,17032,22033,28034,33035,39036,44037,50038,55039,60040,70041,80042,90044,00046,10046,85047,59048,34049,08049,83050,57051,32052,06052,81053,55054,30055,05055,80056,85057,90058,90059,17059,44059,71059,98060,25060,52060,79061,06061,33061,60061,87062,14062,41062,68062,95063,200kW7.47.78.28.58.89.19.49.810.110.410.711.011.311.611.912.212.612.913.513.713.914.214.414.614.815.015.315.515.715.916.116.416.717.017.317.317.417.517.617.717.717.817.918.018.118.118.218.318.418.418.5Min101110531096116112271292135714231488155416191685175018161859190319471991203520832132218022292277232523742422247125192568261627132817289628962896294629462946294629462946294629462977297729772977297729772977Rating168417551826193520442153226223722481259026992808291730263099317232453318339134723553363437143795387639574037411841994280436045224696482648264826491049104910491049104910491049104961496149614961496149614961Max193720192100222523512476260227272853297831043229335534803564364837323816390039934086417942714364445745504643473648294921501452005400555056505650565056505650565056505650565056505650565056505650565056505650232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273Btu/h15,45616,12816,80017,47218,14418,81619,48820,16020,83221,50422,17622,84823,52024,19224,86425,53626,20826,88027,55228,22428,89629,56830,24030,91231,58428,80029,40030,00030,60031,20031,80032,40033,00033,60034,20034,80035,40036,00036,60037,20037,80038,40039,00039,60040,20040,80041,40042,00042,60043,20043,800Min RatingMaxMin Rating MaxkW4.54.74.95.15.35.55.75.96.16.36.56.76.97.17.37.57.77.98.18.38.58.78.99.19.38.48.68.89.09.19.39.59.79.810.010.210.410.510.710.911.111.311.411.611.812.012.112.312.512.712.8Btu/h25,76026,88028,00029,12030,24031,36032,48033,60034,72035,84036,96038,08039,20040,32041,44042,56043,68044,80045,92047,04048,16049,28050,40051,52052,64053,00053,50054,00054,50055,00055,50056,00056,50057,00057,23657,47257,70857,94458,18058,41658,65258,88859,12459,36059,59659,83260,06860,30460,54060,77661,012kW7.57.98.28.58.99.29.59.810.210.510.811.211.511.812.112.512.813.113.513.814.114.414.815.115.415.515.715.816.016.116.316.416.616.716.816.816.917.017.017.117.217.317.317.417.517.517.617.717.717.817.9Btu/h273652848229600308693213833407346763594537214384833975241021422904356044648457364682447912490005028651572528585414455430567165800058292585845887659168594605975060375610006117661353615296170661882620596223562412625886276562941631186329463471636476382464000kW8.08.38.79.09.49.810.210.510.911.311.612.012.412.813.113.413.714.014.414.715.115.515.916.216.617.017.117.217.317.317.417.517.717.917.918.018.018.118.118.218.218.318.318.418.418.518.518.618.718.718.8149715461643169617431791183918871935198320302078212622172264231123582405245224872523255825932629266426992735277028052841287629112817273627362736273627392742274527482751275427572757275727602763276627692772W249525762739282629062986306531453225330433843464354336963774385239304009408741464205426443224381444044994558461746764734479348524696456045604560456045654570457545804585459045954595459546004605461046154620286929633150325033423433352536173708380038923983407542504340443045204610470047684835490349715038510651745242530953775445551255805400534053405371540254335464549555265557558856505650565056505650565057005700Note :1.Cooling Capacity is based on : indoor temp.27°C DB, 19°C WB; outdoor temp. 35°C DB2.Heating Capacity is based on : indoor temp.20°C DB; outdoor temp. 7°C DB, 6°C WB3.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant.Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.4.Total capacity index of indoor unit should be within 23~73 kBtu/h(40%~130%)5.At least two indoor units should be connected.<strong>Multi</strong> <strong>Split</strong> <strong>System</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!