ResultsThe requirements for the EPA method 610 were achievedwith separation of all of the sixteen <strong>PAHs</strong> using theTraceGOLD TG-5SilMS on a GC/MS system. Thestationary phase in the TraceGOLD TG-5SilMS providesexcellent performance due to minimal interaction of activecompounds with active sites on the column, therefore nosignificant peak tailing was observed. The excellentseparation achieved using this column makes it applicableto the analysis of EPA method 8100. Figure 1 shows theTIC chromatogram for a 1 ng/µL of <strong>PAHs</strong> in a mixture ofdichloromethane and benzene obtained using aTraceGOLD TG-5SilMS column. Table 1 shows the peakidentification of compounds according to the retentiontimes on a TraceGOLD TG-5SilMS.ConclusionsThe TraceGOLD TG-5SilMS column demonstratedexcellent performance for the analysis of <strong>PAHs</strong> displayingFigure 1: TIC chromatogram of 1 ng/µL of <strong>PAHs</strong> separated on a TG-5SilMS column<strong>PAHs</strong>IS132ISPeak No.Internal StandardISNaphthalene 1Acenaphthylene 2Internal StandardISAcenaphthene 3Fluorene 4Internal StandardISPhenanthrene 5Internal StandardISAnthracene 6Fluoranthene 74PAHIS 5 IS 6excellent selectivity. The chromatogram illustrates thesuperior performance of the TraceGOLD TG-5SilMS forthe analysis of <strong>PAHs</strong> in accordance with EPA methods610 and 8100.References1. EPA method 610:www.epa.gov/waterscience/methods/method/organics/610.pdf2. EPA method 8100:www.epa.gov/osw/hazard/testmethods/sw846/pdfs/8100.pdfAcknowledgementMany thanks to the dedicated team at Cromlab S.L.,Barcelona, Spain for all of their help providing the data forthis application.7 8Time (min)Peak No.Pyrene 8Benz(a)anthracene 9Chrysene 10Benzo(b)fluoranthene 11Benzo(k)fluoranthene 12Benzo(a)pyrene 13Internal StandardISIndeno(1,2,3-cd)pyrene 14Dibenz(a,h)anthracene 15Benzo(g,h,i)perylene 1610911 12 13IS151614In addition to theseoffices, <strong>Thermo</strong> Fisher<strong>Scientific</strong> maintainsa network of representativeorganizationsthroughout the world.North AmericaUSA and Canada+1 800 332 3331EuropeFrance+33 (0)1 60 92 48 34Germany+49 (0) 2423 9431 -20or -21Switzerland+41 56 618 41 11United Kingdom+44 1928 534110AsiaJapan+81 3 5826 1615China+86-21-68654588or +86-10-84193588800-810-5118India1800 22 8374 (toll-free)+91 22 6716 2200<strong>Thermo</strong> Fisher<strong>Scientific</strong> AustraliaPty Ltd1300 735 292 (free calldomestic)<strong>Thermo</strong> Fisher<strong>Scientific</strong> NewZealand Ltd0800 933 966 (free calldomestic)All Other Enquiries+44 (0) 1928 534 050TechnicalSupportNorth America800 332 3331Outside NorthAmerica+44 (0) 1928 534 440Table 1: List of Polynuclear Aromatic Hydrocarbons (<strong>PAHs</strong>) compounds according to retention timeswww.thermoscientific.com/chromatography©2011 <strong>Thermo</strong> Fisher <strong>Scientific</strong> Inc. All rights reserved. All trademarks are the property of <strong>Thermo</strong> Fisher <strong>Scientific</strong> Inc. and its subsidiaries.Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.ANCCSGCPAHWTR 0311Part of <strong>Thermo</strong> Fisher <strong>Scientific</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!