Installation continued...Bunded tanksA typical bunded fuel oil storage tank installation300mm min300mm minNon-fire rated boundary300mm min760mm minFire Prevention ClearancesTank to be installed inaccordance with therequirements of BS5410 andsimplified in OFTEC documentTI14.Base100mm thick 1:2:4 concretemix or 65x215mm precastconcrete lintels to BS 5977 or50mm thick paving slabs300mm min1.8m minNon-fire rated wall of buildingExpansion ClearanceTank must be installed withclearance of 150mm all roundto allow for expansion when fullof fuel.Tank Support BaseMaintenance ClearancesBunded tanks need a clearanceof 600mm all round to allowpossible inspection of inner tankby removal of outer bund topcover.Tank Support BaseBase must fully support the tankwith no overhangs or gaps.Compacted hardcoreNote: Large tanks requirethicker bases. Consult OFTECor an OFTEC registeredengineer for advice.◗ Store in an upright position, support the entire base of thetank on a firm, flat, level surface ensuring that the area isfree from any sharp stones or other debris<strong>Tanks</strong> providing fuel oil todomestic users (single familydwellings with a capacityof less than 3500ltrs) mustcomply with the requirementsof OFTEC Technical Book 3:Section 2.7. An OFTECregistered engineercan provide full details.◗ The tank must be adequately separated from anysurrounding structures (HSE guidelines suggest 4m). Theseparation between other tanks should be the minimumneeded for safe construction and operation. We recommenda minimum of 300mm (12”) all round. Also allow spaceabove the tank for the hinged access cover to fully open◗ Position the tank ensuring best access for filling,maintenance and safety◗ Ensure the tank is protected from strong wind (especiallywhen empty). If necessary strap it down. Be careful not toinduce too much force when tying down as to distort productshape◗ Connect all pipework, fittings, accessories and supportstructures◗ The tank and the integrity of seals could be affected ifpipework and fittings are not suitably supported◗ Use PTFE tape or Stag compound for jointing◗ Do not allow factory fitted outlets to become loose or turnduring fitting of accessories or fuel supply pipes. The 1” BSPbottom outlet fitting (where applicable) is set at anoptimum torque (45 lb/ft, 61Nm) for O-ring seals on theouter tank wall◗ If gravity feed is not suitable for your application see yourauthorised distributor for information on pumps◗ Clearly label the tank to identify the contents and anyrelevant safety information12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!