31.07.2015 Views

Baths & Circulators

Baths & Circulators

Baths & Circulators

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TEMPERATURE & HUMIDITY CHAMBERSThe equipment for test results in compliance withthe ICH Guideline.Stability Testing Q1A (R2)-ICH, TG Chamber series.Photostability Testing Q1B (Option 2)-ICH Chamber series.105Constructional featuresHigh quality 304 stainless steel exterior and interior.Casters for easy transport and installation.Convenient maintenance.- Available to check total operating time.Exclusive door lock & trim.Vice lock type door catch and foamed silicone packingensure perfect chamber seal.Cable port for running in wires.Basic hole of 50mm diameter cable port is standardequipped on left side of chambers for wiring to thespecimen. We also provide additional 50 or 80mmdiameter cable port. (Optional)Water tank for easy water supply.- Maintenance can be done easily from the front side.Door locker. (Optional)Cyclic defrost function makes less influence to theTemperature & Humidity control for long termoperation.(Under 15 set value)Powerful 2 sirocco fans maintain constant air flow rate inthe chamber.Control OperationMicroprocess PID control / Auto-tuning / Calibration.Digital LCD display with touch-sensitive 7 keypads.Easy operation with wide LCD screen.- Temperature & humidity / timer settings and operatingcondition.The program patterns are memorized for 10 years eventhough the main power switch off, thanks to a PCB builtinbattery.Expansionary parameters inputting.(Conveniently display by letters)Programming operation.Computer interface.- Available to save all data in Excel.- Provide a software.- The program information, setting values backup /recovery, and temperature / humidity values memory.- RS-232C as standard offer.Recorder. (Optional)- 6-point dots type recorder with digital display.- Digital recorder. (6-Channels)Environmental ChambersAdditional TH-ICH 300, 800 FeaturesThis apparatus correctly transfers and controls each lightafter detecting it provides accurate data in the event ofvalidation, equipped with light detectors.(UV light sensor / VIS light sensor)Sample has to be exposed to the light in which completelynear UV energy of less than 200W-hr / m2 is provided tocompare directly the results from overall intensity of lessthan 1.20 million lux-hr, drug substances and reagents.Convenient indication - displayed total fluorescent lamps& UV lamps’ operating time.Safety FunctionsLeakage breaker for power supply.Over current protector.Overheat protector.Switch-off after alarm for over heating.Door open warning alarm.Water empty.Vice lock door closing equipment. (Optional)Alarming when complete Photostability Test.(Only TH-ICH series)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!