Unicell Dust Collectors
Unicell Dust Collectors
Unicell Dust Collectors
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Data Sheet<strong>Unicell</strong> <strong>Dust</strong> <strong>Collectors</strong> – Series C10-90205Compressedair inlet(½" B.S.P. Parallel)270117Compressedair inlet(½" B.S.P. Parallel)255SIDE ELEVATIONAll C10-30 collectorsSIDE ELEVATIONC40-90 hopper and venting type collectorsand all C40-90 collectors supplied with PT controlleror optional compressed air assembly50Compressedair inlet(½" B.S.P. Parallel)212267Joint lineFRONT ELEVATIONSIDE ELEVATIONC40-90 standard and venting type collectors with dust container or rotary valve**For C40-90 collectors supplied with PT controller or optional compressed air assembly, refer to illustration at top-right of pagePOSITION OF COMPRESSED AIR CONNECTION TO COLLECTORTypeCOMPRESSED AIR REQUIREMENTSAtmosphericWorking compressedair volume - F.A.D.air pressure ab at 12 sec. intervals cPulse durationC10 4.2 bar 60 psig 9.1 m 3 /h 5.4 cfm 200 millisec.C20 4.2 bar 60 psig 9.1 m 3 /h 5.4 cfm 200 millisec.C30 4.2 bar 60 psig 12.0 m 3 /h 7.1 cfm 200 millisec.aNormal operating pressure bRecommended atmospheric air volume of clean, dry compressed aircRecommended initial settings; these may be varied with experience12