3-2-3. DC Input Terminal:Connect DC input terminal to 12V / 24V / 48V battery or the otherpower sources.【+】represents positive, and【-】represents negative. Reversepolarity connection will blow the internal fuse and may damage theinverter permanently.ModelMinimumDC Input VoltageMaximum12 V 10.5 15.024 V 21.0 30.048 V 42.0 60.03-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis.WARNING!Operating the inverter without a proper groundConnection may cause an electrical hazard.3-3. Protections Features:DC Input (VDC)Over Temperature ProtectionModelOver VoltageRestartUnderVoltageAlarmUnderVoltageShutdownShutdownShutdownRestart INTERIORRestart ShutdownHEAT SINKRestart12 V 15.3 14.2 11.0 10.5 12.524 V 30.6 28.4 22.0 21.0 25.070℃ 45℃ 90℃ 60℃48V 61.2 56.8 44.0 42.0 50.015