<strong>frenomat</strong> 2/<strong>frenostat</strong> 1000/<strong>frenostat</strong> 2000 electronic brake units<br />

Technical data<br />

Maximum braking current:<br />

<strong>frenomat</strong> 2<br />

<strong>frenostat</strong> 2000 Size 1<br />

<strong>frenostat</strong> 2000 Size 2<br />

<strong>frenostat</strong> 2000 Size 3<br />

<strong>frenostat</strong> 2000 Size 4<br />

30 A<br />

36, 60 A<br />

100, 150, 200 A<br />

300, 400, 500 A<br />

750, 1000, 1500 A<br />

Input braking voltage:<br />

+ 10%/ - 15% at 50 to 60 Hz<br />

230 V to 500 V<br />

higher than 500 V on request<br />

Max. output braking voltage:<br />

(V) DC<br />

Line voltage<br />

AC<br />

Braking current<br />

DC<br />

230 V 80 V<br />

400 V 160 V<br />

500 V 190 V<br />

660 V 270 V<br />

Ambient temperature:<br />

- 25°C to + 45°C at nominal output;<br />

and + 60°C, reduction in at temperatures<br />

between + 45°C braking current of 1.5%<br />

necessary per °C<br />

Contact load:<br />

250 V / 5 A (at terminals 3 and 4)<br />

Braking time:<br />

0 to 12 seconds;<br />

when a standstill monitoring the braking<br />

time is set automatically unit is connected<br />

to terminal n1/T3<br />

ON time:<br />

20% in relation to 1 min. (12 s/min.)<br />

Please inquire about longer ON times<br />

External fuses:<br />

<strong>frenomat</strong> – max. 16 A<br />

<strong>frenostat</strong> – approx. 150%<br />

of rated motor current<br />