3.5. Wiring layout<br />
RTFS/RTN models only, equipped<br />
with NTC probe external cylinder and<br />
temperature adjustment on boiler<br />
RTFS/RTN models only, equipped<br />
with bulb probe external cylinder and<br />
temperature adjustment on cylinder<br />
(optional)<br />
F1 BIT<br />
F2 PIA<br />
F3 RIS<br />
F4 BOL<br />
F5 MIC<br />
F6 MAC<br />
Bi-thermal heat exchanger boiler<br />
Mono-thermal heat exchanger boiler<br />
and AQUA PREMIUM boiler<br />
CH only boiler<br />
System boiler<br />
Micro-reservoir boiler<br />
“AQUA PREMIUM “ boiler<br />
(encased models only)<br />
M3: Power supply connector<br />
M8: External probe<br />
M9: TA (room thermostat)<br />
M16: Tele-metering connector<br />
M2-M15: Boiler component connectors<br />
E.RIV: Detection electrode<br />
E.ACC: Ignition electrode<br />
TL:<br />
P : Water pump<br />
PV:<br />
V: Fan (model TFS only)<br />
TF:<br />
MVD: Three-way valve motor<br />
DK: Low water pressure switch<br />
SR: CH probe (10 Ohm B = 3435)<br />
SE: External temperature probe (10 Ohm B =<br />
3977 - Optional)<br />
SS: DHW probe (10 Ohm B = 3435 max. length TIMER:<br />
three metres)<br />
TA: Room thermostat (Optional)<br />
CM1-CM2: Boiler type selection jumpers<br />
FL: Flow sensor<br />
VG: Gas valve<br />
Limit thermostat<br />
Fan pressure switch (model TFS only)<br />
Flue gas leak detection thermostat (model<br />
TN only)<br />
B: Probe-equipped external cylinder (remove<br />
R1)<br />
B1: Bulb probe-equipped external water cylinder<br />
(remove P1)<br />
DHW programmer (remove P1 when timer is<br />
installed)<br />
P1: Timer priority jumper<br />
R1: 10k Ohm resistance<br />
S: Bulb probe<br />
TR.ACC: Ignition transformer<br />
pic. 29 - Electric layout<br />
T (°C) 0 2 4 6 8<br />
0 27203 24979 22959 21122 19451<br />
10 17928 16539 15271 14113 13054<br />
20 12084 11196 10382 9634 8948<br />
30 8317 7736 7202 6709 6254<br />
40 5835 5448 5090 4758 4452<br />
50 4168 3904 3660 3433 3222<br />
60 3026 2844 2674 2516 2369<br />
70 2232 2104 1984 1872 1767<br />
80 1670 1578 1492 1412 1336<br />
90 1266 1199 1137 1079 1023<br />
No. 10 table - Relation between temperature (°C) and nominal resistance (Ohm) of CH probe SR and DHW probe SS<br />