<strong>PRIME</strong> <strong>1460</strong> <strong>ekW</strong> <strong>1825</strong> <strong>kVA</strong><br />

<strong>50</strong> <strong>Hz</strong> 1<strong>50</strong>0 <strong>rpm</strong> <strong>11</strong> <strong>000</strong> <strong>Volts</strong><br />

TECHNICAL DATA<br />

Open Generator Set - - 1<strong>50</strong>0 <strong>rpm</strong>/<strong>50</strong> <strong>Hz</strong>/<strong>11</strong> <strong>000</strong> <strong>Volts</strong> DM7962<br />

Low Fuel Consumption<br />

Generator Set Package Performance<br />

Genset Power rating @ 0.8 pf<br />

Genset Power rating with fan<br />

<strong>1825</strong> <strong>kVA</strong><br />

<strong>1460</strong> <strong>ekW</strong><br />

Coolant to aftercooler<br />

Coolant to aftercooler temp max 82 ° C 180 ° F<br />

Fuel Consumption<br />

100% load with fan<br />

75% load with fan<br />

<strong>50</strong>% load with fan<br />

Cooling System1 Air flow restriction (system)<br />

Air flow (max @ rated speed for radiator arrangement)<br />

Engine Coolant capacity with radiator/exp. tank<br />

Engine coolant capacity<br />

Radiator coolant capacity<br />

382.7 L/hr 101.1 Gal/hr<br />

292.0 L/hr 77.1 Gal/hr<br />

209.2 L/hr 55.3 Gal/hr<br />

0.12 kPa 0.48 in. water<br />

1543 m³/min 54491 cfm<br />

398.0 L 105.1 gal<br />

233.0 L 61.6 gal<br />

165.0 L 43.6 gal<br />

Inlet Air<br />

Combustion air inlet flow rate <strong>11</strong>5.7 m³/min 4085.9 cfm<br />

Exhaust System<br />

Exhaust stack gas temperature<br />

Exhaust gas flow rate<br />

Exhaust flange size (internal diameter)<br />

Exhaust system backpressure (maximum allowable)<br />

Heat Rejection<br />

Heat rejection to coolant (total)<br />

Heat rejection to exhaust (total)<br />

Heat rejection to aftercooler<br />

Heat rejection to atmosphere from engine<br />

Heat rejection to atmosphere from generator<br />

Alternator2 Motor starting capability @ 30% voltage dip<br />

Frame<br />

Temperature Rise<br />

477.6 ° C 891.7 ° F<br />

304.2 m³/min 10742.7 cfm<br />

203.2 mm 8.0 in<br />

6.7 kPa 26.9 in. water<br />

961 kW 54652 Btu/min<br />

1380 kW 78480 Btu/min<br />

191 kW 10862 Btu/min<br />

159 kW 9042 Btu/min<br />

67.2 kW 3821.7 Btu/min<br />

3928 s<strong>kVA</strong><br />

27<strong>50</strong><br />

105 ° C 189 ° F<br />

Lube System<br />

Sump refill with filter 401.3 L 106.0 gal<br />

Emissions (Nominal) 3<br />

NOx mg/nm3<br />

CO mg/nm3<br />

HC mg/nm3<br />

PM mg/nm3<br />

7168.2 mg/nm³<br />

328.6 mg/nm³<br />

95.7 mg/nm³<br />

34.7 mg/nm³<br />

1 For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory.<br />

2 UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator<br />

temperature rise is based on a 40 degree C ambient per NEMA MG1-32.<br />

3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for<br />

measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77°F, 28.42 in HG and number 2 diesel fuel<br />

with 35° API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and<br />

engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use<br />

values based on a weighted cycle.<br />

4<br />

July 26 20<strong>11</strong> 14:55 PM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!