Newport e500Ventilator

Newport e500Ventilator - Newport NMI Ventilators

Newport e500Ventilator - Newport NMI Ventilators

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Dimensions<br />

e500 with GDM on Deluxe Cart:<br />

Width: 20.5 in (52 cm) at base<br />

Depth: 26 in (66 cm) at base<br />

Total Weight: 164 lbs. (75 kg) ship weight<br />

Total Height: 62.5 in (158.7 cm) e500 & GDM mounted<br />

Environmental<br />

Operating:<br />

Relative humidity: 10 to 95% Rh non-condensing<br />

Altitude: 0 to 13,124 feet (0 to 4000 meters)<br />

Pressure: 21 to 31 in. Hg (700 to 1060 hPa)<br />

Storage:<br />

Ambient temperature: -40 to 70 °C (-40 to 158 °F)<br />

Relative humidity: 10 to 95% Rh non-condensing<br />

Altitude: 0 to 18,000 feet (0 to 5500 meters)<br />

Pressure: 15 to 31 in. Hg (500 to 1060 hPa)<br />

Gas Supply Requirements<br />

Air and O 2 Supply Inlet Pressure: 30 to 90 psig, 50 psig nominal<br />

External Connections<br />

REMOTE ALARM:<br />

Normally open (NO) contact, nurse call or remote system must<br />

operate as a normally open system - 250mA @ 100VDC, allowable<br />

current at max. voltage between relay contact < .2 ohms,<br />

max. initial contact resistance<br />

GRAPHICS MONITOR:<br />

Input for Graphic Display Monitor (GDM) communication cable<br />

RS 232C:<br />

9-pin D-shell, 38,400 baud. For use with central monitoring systems.<br />

CONTROL PANEL:<br />

Input for Control Panel Module (CPM) communication cable<br />

EXTERNAL ALARM SILENCE:<br />

Input for <strong>Newport</strong> external alarm silence cable<br />

EXTERNAL BATTERY 12 VDC:<br />

Input for an external battery<br />

Patient Circuit Connections<br />

Inspiratory and expiratory limb connectors: 22-mm OD<br />

Proximal tubing connector: 1/8 in. (0.32 cm) ID to fit 1/8 in. (0.32<br />

cm) ID proximal pressure tubing<br />

Ordering the e500 Ventilator System<br />

The <strong>Newport</strong> e500 Ventilator System includes the Gas<br />

Delivery Unit, Control Panel Module, Graphics<br />

Display Monitor and Deluxe Cart.<br />

Order: E500-NC-US<br />

Standard accessories included:<br />

Built-in heated, permanent exhalation valve assembly<br />

Built-in oxygen sensor<br />

Support arm and breathing circuit hanger<br />

Air and oxygen hoses, 10 ft (3 m) with DISS fittings<br />

Air and oxygen inlet water traps<br />

Disposable bacteria filters (2)<br />

Disposable proximal inline filters (5)<br />

Operating Manual<br />

Additional accessories:<br />

Disposable insp. bacteria filters / cs 50 FLT1800Q-C<br />

Disposable exp. bacteria filters FLT1875P<br />

Proximal inline filter / 5 ea<br />

FLT1850DC<br />

Reusable adult patient breathing circuit PBC345A<br />

Reusable ped/infant breathing circuit PBC450A<br />

Disposable adult patient<br />

breathing ciruit / cs 20 51006600<br />

Disposable ped/infant patient<br />

breathing circuit / cs 20 51006500<br />

Disposable water trap<br />

WTR134P<br />

Printer cable<br />

CBL1900Q<br />

Adult test lung with restrictor LNG800P<br />

Preventive maintenance kit<br />

PMK500A<br />

Oxygen sensor<br />

R125P03-002<br />

For current accessories and price information or to<br />

place an order contact your local distributor or<br />

<strong>Newport</strong> Customer Service Department.<br />

tel: 1.800.451.3111 ext. 282<br />

fax: 1.949.548.3091<br />

email: Customers@<strong>Newport</strong>NMI.com<br />

www.ventilators.com<br />

Specifications subject to change without notification.