Dimensions<br />
e500 with GDM on Deluxe Cart:<br />
Width: 20.5 in (52 cm) at base<br />
Depth: 26 in (66 cm) at base<br />
Total Weight: 164 lbs. (75 kg) ship weight<br />
Total Height: 62.5 in (158.7 cm) e500 & GDM mounted<br />
Environmental<br />
Operating:<br />
Relative humidity: 10 to 95% Rh non-condensing<br />
Altitude: 0 to 13,124 feet (0 to 4000 meters)<br />
Pressure: 21 to 31 in. Hg (700 to 1060 hPa)<br />
Storage:<br />
Ambient temperature: -40 to 70 °C (-40 to 158 °F)<br />
Relative humidity: 10 to 95% Rh non-condensing<br />
Altitude: 0 to 18,000 feet (0 to 5500 meters)<br />
Pressure: 15 to 31 in. Hg (500 to 1060 hPa)<br />
Gas Supply Requirements<br />
Air and O 2 Supply Inlet Pressure: 30 to 90 psig, 50 psig nominal<br />
External Connections<br />
REMOTE ALARM:<br />
Normally open (NO) contact, nurse call or remote system must<br />
operate as a normally open system - 250mA @ 100VDC, allowable<br />
current at max. voltage between relay contact < .2 ohms,<br />
max. initial contact resistance<br />
GRAPHICS MONITOR:<br />
Input for Graphic Display Monitor (GDM) communication cable<br />
RS 232C:<br />
9-pin D-shell, 38,400 baud. For use with central monitoring systems.<br />
CONTROL PANEL:<br />
Input for Control Panel Module (CPM) communication cable<br />
EXTERNAL ALARM SILENCE:<br />
Input for <strong>Newport</strong> external alarm silence cable<br />
EXTERNAL BATTERY 12 VDC:<br />
Input for an external battery<br />
Patient Circuit Connections<br />
Inspiratory and expiratory limb connectors: 22-mm OD<br />
Proximal tubing connector: 1/8 in. (0.32 cm) ID to fit 1/8 in. (0.32<br />
cm) ID proximal pressure tubing<br />
Ordering the e500 Ventilator System<br />
The <strong>Newport</strong> e500 Ventilator System includes the Gas<br />
Delivery Unit, Control Panel Module, Graphics<br />
Display Monitor and Deluxe Cart.<br />
Order: E500-NC-US<br />
Standard accessories included:<br />
Built-in heated, permanent exhalation valve assembly<br />
Built-in oxygen sensor<br />
Support arm and breathing circuit hanger<br />
Air and oxygen hoses, 10 ft (3 m) with DISS fittings<br />
Air and oxygen inlet water traps<br />
Disposable bacteria filters (2)<br />
Disposable proximal inline filters (5)<br />
Operating Manual<br />
Additional accessories:<br />
Disposable insp. bacteria filters / cs 50 FLT1800Q-C<br />
Disposable exp. bacteria filters FLT1875P<br />
Proximal inline filter / 5 ea<br />
FLT1850DC<br />
Reusable adult patient breathing circuit PBC345A<br />
Reusable ped/infant breathing circuit PBC450A<br />
Disposable adult patient<br />
breathing ciruit / cs 20 51006600<br />
Disposable ped/infant patient<br />
breathing circuit / cs 20 51006500<br />
Disposable water trap<br />
WTR134P<br />
Printer cable<br />
CBL1900Q<br />
Adult test lung with restrictor LNG800P<br />
Preventive maintenance kit<br />
PMK500A<br />
Oxygen sensor<br />
R125P03-002<br />
For current accessories and price information or to<br />
place an order contact your local distributor or<br />
<strong>Newport</strong> Customer Service Department.<br />
tel: 1.800.451.3111 ext. 282<br />
fax: 1.949.548.3091<br />
email: Customers@<strong>Newport</strong>NMI.com<br />
www.ventilators.com<br />
Specifications subject to change without notification.