Orbital Motors Type OMP OMR and OMH Technical Information
Orbital Motors Type OMP, OMR and OMH Technical ... - Bibus
Orbital Motors Type OMP, OMR and OMH Technical ... - Bibus
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>OMP</strong><br />
<strong>Technical</strong> <strong>Information</strong><br />
<strong>Technical</strong> Data<br />
<strong>Technical</strong> data for <strong>OMP</strong> with 25 mm <strong>and</strong> 1 in cylindrical shaft (continued)<br />
<strong>Type</strong> <strong>OMP</strong> <strong>OMP</strong> <strong>OMP</strong> <strong>OMP</strong> <strong>OMP</strong> <strong>OMP</strong> <strong>OMP</strong><br />
Motor size 110 125 160 200 250 315 400<br />
Geometric displacement cm 3<br />
Max. speed<br />
Max. torque<br />
Max. output<br />
Max. pressure drop<br />
Max. oil flow<br />
Max. starting pressure with<br />
unloaded shaft<br />
Min starting torque<br />
bar<br />
[psi]<br />
[inch]<br />
112.5<br />
[6.87]<br />
125.0<br />
[7.65]<br />
155.7<br />
[9.53]<br />
194.6<br />
[11.91]<br />
242.3<br />
[14.83]<br />
306.1<br />
[18.73]<br />
389.2<br />
[23.82]<br />
min -1 cont. 535 480 385 310 250 195 155<br />
[rpm] int 1 ) 670 600 480 385 310 245 190<br />
N•m<br />
[lbf•in]<br />
kW<br />
[hp]<br />
bar<br />
[psi]<br />
l/min<br />
[US gal/min]<br />
st<strong>and</strong>ard<br />
free running<br />
gerotor<br />
cont.<br />
int. 1 )<br />
215<br />
[1900]<br />
260<br />
[2300]<br />
peak 2) 320<br />
[2830]<br />
cont.<br />
int. 1 )<br />
cont.<br />
int 1 )<br />
10<br />
[13.4]<br />
12.0<br />
[16.1]<br />
140<br />
[2030]<br />
175<br />
[2540]<br />
peak 2) 225<br />
[3260]<br />
cont.<br />
int. 1 )<br />
at max. press drop cont.<br />
N•m [lbf•in]<br />
at max. press.drop int. 1 )<br />
N•m [lbf•in]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
10<br />
[145]<br />
-<br />
190<br />
[1680]<br />
240<br />
[2120]<br />
240<br />
[2120]<br />
290<br />
[2570]<br />
370<br />
[3280]<br />
10<br />
[13.4]<br />
12.0<br />
[16.1]<br />
140<br />
[2030]<br />
175<br />
[2540]<br />
225<br />
[3260]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
9<br />
[130]<br />
2<br />
[29]<br />
210<br />
[1860]<br />
270<br />
[2390]<br />
1)<br />
Intermittent operation: the permissible values may occur for max. 10% of every minute.<br />
2)<br />
Peak load: the permissible values may occur for max. 1% of every minute.<br />
300<br />
[2660]<br />
370<br />
[3280]<br />
430<br />
[3810]<br />
10<br />
[13.4]<br />
12.0<br />
[16.1]<br />
140<br />
[2030]<br />
175<br />
[2540]<br />
225<br />
[3260]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
7<br />
[100]<br />
2<br />
[29]<br />
280<br />
[2480]<br />
350<br />
[3100]<br />
300<br />
[2660]<br />
380<br />
[3360]<br />
540<br />
[4780]<br />
8.0<br />
[10.7]<br />
11.0<br />
[14.8]<br />
115<br />
[1670]<br />
150<br />
[2180]<br />
225<br />
[3260]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
5<br />
[75]<br />
2<br />
[29]<br />
270<br />
[2390]<br />
360<br />
[3190]<br />
300<br />
[2660]<br />
410<br />
[3630]<br />
550<br />
[4870]<br />
6.0<br />
[8.1]<br />
9.0<br />
[12.1]<br />
90<br />
[1310]<br />
125<br />
[1810]<br />
180<br />
[2610]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
5<br />
[75]<br />
300<br />
[2660]<br />
390<br />
[3450]<br />
600<br />
[5310]<br />
5.0<br />
[6.7]<br />
7.0<br />
[9.4]<br />
75<br />
[1090]<br />
100<br />
[1450]<br />
160<br />
[2320]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
5<br />
[75]<br />
300<br />
[2660]<br />
420<br />
[3720]<br />
600<br />
[5310]<br />
4.0<br />
[5.4]<br />
6.0<br />
[8.1]<br />
60<br />
[870]<br />
80<br />
[1160]<br />
130<br />
[1890]<br />
60<br />
[15.9]<br />
75<br />
[19.8]<br />
5<br />
[75]<br />
- - -<br />
280<br />
[2480]<br />
390<br />
[3450]<br />
280<br />
[2480]<br />
370<br />
[3280]<br />
280<br />
[2480]<br />
400<br />
[3540]<br />
520L0262 • Rev CB • Apr 2009<br />
11