THE BIG INVERTER FAMILY<br />
THE RIGHT ONE TO SUIT ALL REQUIREMENTS<br />
The most important criteria for selecting a<br />
photovoltaic installation are reliability, longevity<br />
and cost effectiveness. The inverter - the heart of<br />
the photovoltaic installation - plays an important<br />
role here. It is the link between the PV modules<br />
and the public electricity grid. By means of the<br />
inverter, the DC voltage generated in the modules<br />
is converted into the AC voltage conforming to<br />
the grid.<br />
PS 1200 PS 2000 PS 3000 PS 4000 PS 5000 PS 6000<br />
Nominal PV generator 810 W 1600 W 2700 W 3200 W 4300 W 4800 W<br />
power PPVnom<br />
Maximum PV<br />
generator power PPVmax 1100 W 1950 W 3200 W 3900 W 5100 W 5850 W<br />
Input<br />
voltage<br />
area UPV<br />
in 2 implementations<br />
MPP tension<br />
range<br />
High-voltage suitable for<br />
modules with 5 inch cell<br />
technology (Maximum<br />
input voltage, UPVmax)<br />
Medium voltage suitable<br />
for modules with 6 inch<br />
cell technology (Maximum<br />
input voltage, UPVmax)<br />
HV<br />
MV<br />
200 V - 200 V - 200 V - 200 V - 200 V - 200 V -<br />
500 V 500 V 500 V 500 V 500 V 500 V<br />
(600 V) (600 V) (600 V) (600 V) (600 V) (600 V)<br />
100 V - 100 V - 100 V - 100 V - 100 V - 100 V -<br />
350 V 350 V 350 V 350 V 350 V 350 V<br />
(450 V) (450 V) (450 V) (450 V) (450 V) (450 V)<br />
DC input module / Independent<br />
MPP-Tracker 1 1 2 2 3 3<br />
Nominal output power, Pnom 825 W 1650 W 2750 W 3300 W 4000 W 4600 W<br />
Maximum output power, Pmax 900 W 1800 W 3000 W 3600 W 4400 W 5000W/5400W<br />
Maximum output current, Imax 4,0 A 8,0 A 13 A 15,5 A 19,2 A 22,0 A<br />
Maximum efficiency 93,4% 93,9% 94,4% 94,4% 94,5% 94,5%<br />
Certification: Powerstocc inverters carry all required certification, which can be provided on inquiry<br />
INDIVIDUAL MPP TRACKING<br />
Every DC performance unit is assigned an individual<br />
MPP-Tracker. Strings with different parameters<br />
can be connected to one inverter and an optimal<br />
yield is nevertheless guaranteed. For example:<br />
· installations with partial shading<br />
· East/West installations<br />
· Different number of modules in each string<br />
· Different types of modules in each string<br />
POWERCONCEPT ®<br />
The inverters from Powerstocc 3000 onward have<br />
several DC performance units. In order to make<br />
better use of diffuse radiation, the strings of the<br />
inverter are interconnected as an internal<br />
master/slave circuit with major advantages.<br />
The master task is taken over by different operative<br />
units depending on the operating hours.<br />
MODULAR DESIGN<br />
Innovation means developing a manageable<br />
service concept. With consistent modular design,<br />
individual units can simply be replaced. The<br />
forward-looking architecture of the Powerstocc<br />
inverter features the cutting edge of the most<br />
modern developments in performance electronics.<br />
CAN-BUS<br />
The reliable and industrially proven data transfer<br />
protocol takes over the internal control of the<br />
Powerstocc inverters. CAN-bus technology has<br />
been applied countless times in the automotive<br />
industry, among other areas, and stands for<br />
security at the uppermost level. With its data<br />
communications galvanically isolated from its<br />
performance section, inverter »downtimes« are as<br />
good as impossible.<br />
Page 8