FINAL CAT_Layout 1 08/02/2011 17:45 Page 147<br />
Fire Protection & Emergency Lighting | Channel<br />
u AlarmSense ® Two Wire Fire Panel<br />
AlarmSense ® Panel<br />
AlarmSense<br />
®<br />
AlarmSense<br />
A1R Heat<br />
Sounder<br />
Detector<br />
Beacon<br />
®<br />
The Two Wire fire panel which gives less expensive and more<br />
flexible installation options. Most conventional fire systems are<br />
designed to work with two pairs of wires per zone: one pair for<br />
detection devices such as smoke detectors, heat detectors and<br />
manual call points; the other for alarm devices such as bells,<br />
sounders or strobes. By using different voltage bands for quiescent<br />
®<br />
and alarm states, AlarmSense components can be connected to<br />
the same pair of supply wires.<br />
When powered and controlled by the AlarmSense ® two-wire fire<br />
panel, this reliable technology takes all the complexity out of fire<br />
alarm system design, leading to quicker, less expensive and more<br />
flexible installation. Research shows an AlarmSense ® two-wire<br />
system can achieve up to 40% reduction of labour over a standard<br />
four wire conventional system. Compliant with EN54 Parts 2 and 4;<br />
installer friendly design; easy first fix and straight forward<br />
maintenance. Flush or surface mountable.<br />
Full details on our website at www.channelsafety.co.uk.<br />
u HARK Disabled Toilet Alarm<br />
An easy to install and expand solution to meet the growing<br />
requirement for a means of indicating that assistance is required.<br />
HARK assists with compliance with the DDA, BS8300 & other care<br />
standards.<br />
HARK Features<br />
Sounder within the reset unit to give audible<br />
reassurance that assistance is on the way.<br />
Braille text on the reset unit.<br />
Only 3 points to install on a standard system.<br />
Can be simply linked to other systems.<br />
Assists in ensuring compliance with the DDA,<br />
BS8300 & other care standards.<br />
Simple to expand.<br />
Multi-way remote indicator units available.<br />
Twin pull cord rings supplied.<br />
Disabled Persons sticker supplied.<br />
Operation<br />
Once the pull cord(s) are activated the reassurance LED on the pull<br />
cord will illuminate, the reset unit will iluminate & operate its<br />
internal sounder and the external lamp/sounder unti will operate<br />
along with any optional equipment installed.<br />
Simply pressing the illuminated reset switch will return the system<br />
to the ‘normal’ state.<br />
www.bemco.co.uk 147