Flood Light Fixture<br />

160W Flood Light Fixture<br />

200W Flood Light Fixture<br />

LitespanLED® Fixtures<br />

Ordering Code Bar Code Watts Volts Lumens Operating<br />

Temp<br />

C0820-FL-160W-40K-N31-S-P-N 93038 160 120-277 VAC 15840 -40C - 55C<br />

C0820-FL-160W-40K-N31-W-N-N 93039 160 120-277 VAC 15840 -40C - 55C<br />

C0820-FL-160W-40K-N31-W-P-N 93040 160 120-277 VAC 15840 -40C - 55C<br />

C0820-FL-160W-50K-N31-BL-N-N 93041 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-BL-P-N 93042 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-BR-N-N 93043 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-BR-P-N 93044 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-S-N-N 93045 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-S-P-N 93046 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-W-N-N 93047 160 120-277 VAC 16800 -40C - 55C<br />

C0820-FL-160W-50K-N31-W-P-N 93048 160 120-277 VAC 16800 -40C - 55C<br />

LitespanLED® Fixtures<br />

240W Flood Light Fixture<br />

Ordering Code Bar Code Watts Volts Lumens Operating<br />

Temp<br />

C0820-FL-200W-40K-N31-BL-N-N 93049 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-BL-P-N 93050 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-BR-N-N 93051 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-BR-P-N 93052 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-S-N-N 93053 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-S-P-N 93054 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-W-N-N 93055 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-40K-N31-W-P-N 93056 200 120-277 VAC 16193 -40C - 55C<br />

C0820-FL-200W-50K-N31-BL-N-N 93057 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-BL-P-N 93058 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-BR-N-N 93059 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-BR-P-N 93060 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-S-N-N 93061 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-S-P-N 93062 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-W-N-N 93063 200 120-277 VAC 21000 -40C - 55C<br />

C0820-FL-200W-50K-N31-W-P-N 93064 200 120-277 VAC 21000 -40C - 55C<br />

Ordering Code Bar Code Watts Volts Lumens Operating<br />

Temp<br />

C0820-FL-240W-40K-N31-BL-N-N 93065 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-BL-P-N 93066 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-BR-N-N 93067 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-BR-P-N 93068 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-S-N-N 93069 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-S-P-N 93070 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-W-N-N 93071 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-40K-N31-W-P-N 93072 240 120-277 VAC 22680 -40C - 55C<br />

C0820-FL-240W-50K-N31-BL-N-N 93073 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-BL-P-N 93074 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-BR-N-N 93075 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-BR-P-N 93076 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-S-N-N 93077 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-S-P-N 93078 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-W-N-N 93079 240 120-277 VAC 25200 -40C - 55C<br />

C0820-FL-240W-50K-N31-W-P-N 93080 240 120-277 VAC 25200 -40C - 55C<br />

High Bay Fixture<br />

120W High Bay Fixture<br />

Ordering Code Bar Code Watts Volts Lumens Operating<br />

Temp<br />

C0820-HB-120W-40K-N39-BR-N-N 93129 120 120-277 VAC 10170 -40C - 55C<br />

C0820-HB-120W-40K-N39-S-N-N 93130 120 120-277 VAC 10170 -40C - 55C<br />

C0820-HB-120W-40K-N39-W-N-N 93131 120 120-277 VAC 10170 -40C - 55C<br />

C0820-HB-120W-40K-N40-BR-N-N 93132 120 120-277 VAC 10162 -40C - 55C<br />

C0820-HB-120W-40K-N40-S-N-N 93133 120 120-277 VAC 10162 -40C - 55C<br />

C0820-HB-120W-40K-N40-W-N-N 93134 120 120-277 VAC 10162 -40C - 55C<br />

C0820-HB-120W-50K-N39-BR-N-N 93135 120 120-277 VAC 10936 -40C - 55C<br />

C0820-HB-120W-50K-N39-S-N-N 93136 120 120-277 VAC 10936 -40C - 55C<br />

C0820-HB-120W-50K-N39-W-N-N 93137 120 120-277 VAC 10936 -40C - 55C<br />

C0820-HB-120W-50K-N40-BR-N-N 93138 120 120-277 VAC 10927 -40C - 55C<br />

C0820-HB-120W-50K-N40-S-N-N 93139 120 120-277 VAC 10927 -40C - 55C<br />

C0820-HB-120W-50K-N40-W-N-N 93140 120 120-277 VAC 10927 -40C - 55C<br />