STANLEY JOHN LTD: STORMWATER CELL SOLUTIONS<br />

INFILTRATION AND ATTENUATION SYSTEMS<br />

Infiltration and Attenuation Systems ■ The AquaCell ® Infiltration and Attenuation Systems Principle<br />

■ The AquaCell ® Principle<br />

Infiltration and Attenuation Systems continued<br />

Garastor ® System*<br />

A polypropylene flow control chamber<br />

connected to a water storage reservoir<br />

EITHER made up of AquaCell units or<br />

located in a void beneath the garage of<br />

individual houses.<br />

* Depending on the application either AquaCell Core or<br />

AquaCell Lite may be used in conjunction with Garastor.<br />

For further details contact Wavin Technical Design.<br />

The AquaCell ® Principle<br />

The AquaCell Stormwater<br />

Management System<br />

Comprises individual infiltration modules<br />

assembled together to form underground<br />

structures which can either be used for<br />

stormwater storage or as an alternative to<br />

domestic soakaways.<br />

Large scale AquaCell Core storage tank<br />

AquaCell Lite soakaway<br />

INFILTRATION AND ATTENUATION SYSTEMS Product & Installation Guide <strong>20</strong>09<br />

www.intesio.co.uk<br />

Garastor domestic storage using AquaCell Core<br />

tank<br />

Note: Garastor can be used as a flow control device<br />

for any AquaCell storage system, no greater than one<br />

unit deep with a discharge of up to 1.4 l/s via the<br />

30mm release flow orifice.<br />

Garastor domestic storage using garage void<br />

* Garastor is manufactured under licence<br />

(Patent Number GB2357093)<br />

Heavy storms and major cloudbursts are Stormwater must be controlled; either by<br />

becoming more frequent, resulting in ever limiting the outflow and providing<br />

increasing volumes of stormwater flowing temporary storage or where the ground<br />

into conventional drainage systems and conditions are suitable, providing<br />

water courses. When the capacities of these soakaways for the stormwater to infiltrate<br />

systems are exceeded the consequences back into the surrounding ground.<br />

can be dramatic and damaging.<br />

This has the added benefit of recharging<br />

the local groundwater.<br />

Both options can be achieved using either<br />

the AquaCell Plus, Core or Lite systems<br />

depending on the application.<br />

Domestic AquaCell Core soakaway<br />

INFILTRATION AND ATTENUATION SYSTEMS<br />

General Introduction ■ The AquaCell ® Principle ■<br />

Infiltration & Attenuation Systems<br />

5<br />