Technical Information | Glossary<br />

Glossary<br />

Positive Displacement Pump<br />

Available on select PolyScience Recirculating Chillers,<br />

this type of pump generates moderate flow at high<br />

pressure. It is best suited for situations where greater<br />

head pressure is needed, such as applications where the<br />

cooling fluid must be pumped some distance or where<br />

in-line pressure is required to activate flow devices.<br />

Pump Pressure<br />

The force of fluid being pumped. The higher the<br />

pressure, the greater the distance that the fluid can<br />

travel. Lower pressure is better for fragile fluid paths,<br />

such as glass tubing. It is measured using water at a<br />

flow rate of 0 gpm (0.0 l/min) at the outlet port of<br />

the unit.<br />

Recirculating Chiller<br />

Interchangeable with Recirculator and Chiller:<br />

See “Chiller/Recirculating Chiller.”<br />

Recirculating Cooler/Heat Exchanger<br />

A closed-loop, non-refrigerated system designed to<br />

cool an external device. Cooling is provided by<br />

transferring heat from the external device to either the<br />

air (Liquid-to-Air Coolers) or to facility cooling water<br />

(Liquid-to-Liquid Coolers).<br />

Refrigerant<br />

A compound used in a refrigeration unit to extract heat<br />

from a process or internal reservoir. All PolyScience<br />

Chillers and Refrigerated Circulators use CFC-free<br />

refrigerants.<br />

Refrigerated/Heated Circulating Bath<br />

A bath with an integral pump, heater, refrigeration<br />

system, and temperature controller. In addition to<br />

low temperature applications, Refrigerated/Heated<br />

Circulating Baths offer more precise control for<br />

applications that require bath temperatures near or<br />

below ambient. All PolyScience Circulating Baths<br />

provide internal circulation as well as external<br />

circulation capability.<br />

Reservoir Capacity/Bath Volume<br />

This specification provides information on how much<br />

liquid the Circulator, Water Bath, or Tank will hold when<br />

filled to maximum capacity. It does not include the<br />

volume of liquid in external tubing or equipment.<br />

118 | Phone: 800-229-7569 • +1-847-647-0611<br />

Simplex Pump<br />

A type of pump that provides pressure flow only, thus<br />

limiting its use to closed-loop applications. PolyScience<br />

Circulating Baths with Standard Digital and MX<br />

<strong>Temperature</strong> <strong>Control</strong>lers are equipped with Simplex<br />

pumps.<br />

SmartTouch Display<br />

An advanced, full-color touch screen display. Featured<br />

on PolyScience Performance Programmable, Advanced<br />

Programmable, and Performance Digital <strong>Temperature</strong><br />

<strong>Control</strong>lers.<br />

Specific Heat<br />

This is a measure of a fluid’s heat capacity (the amount<br />

of heat per unit mass required to raise its temperature<br />

by 1°). The specific heat of water is 1 BTU/lb °F (4.19 KJ/<br />

kg K). PolyScience Circulators with Performance and<br />

Advanced Series <strong>Temperature</strong> <strong>Control</strong>lers can be tuned<br />

for use with specific fluids to enhance performance and<br />

temperature control.<br />

Suction Pressure<br />

This is the pressure generated by the pump at the fluid<br />

intake of a Circulator equipped with a Duplex (pressure/<br />

suction) pump. It is measured using water at a flow rate<br />

of 0 gpm (0.0 l/min).<br />

Swivel 180 Rotating <strong>Control</strong>ler<br />

A (patent-pending) PolyScience exclusive that allows<br />

independent positioning of the Circulating Bath<br />

<strong>Temperature</strong> <strong>Control</strong>ler, thus allowing the operator<br />

to keep the temperature display in sight anywhere<br />

within a 180° viewing radius. Swivel 180 is standard<br />

on all Performance, Advanced, and Standard<br />

<strong>Temperature</strong> <strong>Control</strong>lers.<br />

<strong>Temperature</strong> Accuracy<br />

This represents how well the instrument’s measured<br />

temperature value corresponds to that of a calibrated<br />

standard. For example, the displayed bath temperature<br />

in a Circulating Bath with a set-point of 25.00°C and<br />

a temperature accuracy of ±0.25°C may actually be<br />

as low as 24.75°C or as high as 25.25°C. PolyScience<br />

Circulators, Digital Water Baths, and Chillers feature a<br />

calibration offset that allows the operator to match the<br />

displayed temperature to that of an external device or<br />

calibrated temperature standard.