Xcell 150QVWSB<br />
Mechanical ventilation with heat recovery and summer bypass<br />
Product Selector<br />
Reference Number<br />
Xcell 150QVWSB<br />
93139AW<br />
The Xcell 150QVWSB features a high-efficiency counterflow heat exchanger,<br />
providing up to 90% heat recovery efficiency. This unit is purpose-designed<br />
for modern, airtight apartments and houses, where less natural leakage can<br />
cause increased condensation and mould problems. This model has lightweight<br />
EPP construction and may be floor or wall-mounted in the loft space.<br />
A low-energy EC motor ensures low annual running costs, while the long-life<br />
G4 filter can be inspected with ease – simply remove the front access panel<br />
for effortless maintenance. There’s also a summer bypass facility that stops<br />
the heat exchanger warming incoming fresh air during the summer months,<br />
for year-round comfort.<br />
Trade Price £995.24<br />
Motor Type<br />
EC<br />
Maximum Supply/Extract Performance (FID, m³/h) 150<br />
Maximum Supply/Extract Performance (m³/h @90Pa) 150<br />
Maximum System Pressure (Pa) 90<br />
Power Usage Maximum (W) 220-240V AC 50-60Hz 85<br />
Specific Fan Power (average W/l/s – specific fan power is subject to system design resistance) 0.74<br />
Efficiency (%) 90<br />
Speeds 3<br />
Speed Control Type<br />
Remote variable DC<br />
Noise (dBA@3m) Low/Medium/Max 20/22.5/29.5<br />
Spigot Diameter (mm) 125<br />
Systems<br />
Installation Orientation<br />
Vertical<br />
Weight (kg) 17.5<br />
UK Guarantee (years) 5*<br />
Systems<br />
85mm<br />
4-Ø 125 Spigots<br />
595mm<br />
600mm<br />
Atmosphere Discharge<br />
425mm<br />
Kitchen<br />
+1 Additional Wet Room<br />
100% Variable<br />
S.F.P.<br />
(W/L/S)<br />
Heat Recovery<br />
Efficiency<br />
1.33 88%<br />
+2 Additional Wet Room 1.08 87%<br />
+3 Additional Wet Room 1.17 86%<br />
+4 Additional Wet Room 1.30 86%<br />
+5 Additional Wet Room 1.53 85%<br />
Static Pressure [Pa]<br />
500<br />
400<br />
300<br />
100<br />
0<br />
Flow Rate [l/s]<br />
*5 years on motor – 2 years on other parts<br />
20 40 60 80 100<br />
1.6<br />
1.2<br />
0.8<br />
0.4<br />
Static Resistance [w.g]<br />
Atmosphere Intake<br />
Dwelling Supply<br />
Dwelling Extract<br />
0<br />
0.0<br />
0 40 80 120 140 160<br />
Flow Rate [m 3 /h]<br />
Speed 1 (Holiday/Absent)<br />
Speed 2 (Normal)<br />
Speed 3 (Boost)<br />
ANCILLARIES See pages 106 – 121<br />
76 www.xpelair.co.uk 77