MICROSPHERE REAGENT DEVELOPMENT
2fFrYhF
2fFrYhF
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BEAD ELISAS<br />
Bead-ELISAs have been developed using various types of<br />
microspheres, including micron-range polymer or magnetic<br />
microspheres or submicron polymer spheres. They offer<br />
increased surface area over traditional microplate ELISAs, and<br />
magnetic spheres, with their suitability for automation, can<br />
offer additional benefits with respect to reagent processing and<br />
assay performance. See TN301, Immunological Applications.<br />
Catalog Code Description Bead Size (µm)<br />
PMC1N, PMC3N ProMag Carboxyl 1 & 3<br />
PMC1N, PMC3N ProMag - Streptavidin 1 & 3<br />
PMC3HP ProMag HP - Carboxyl 3<br />
Fluorescent Microspheres: 5.26µm<br />
Glacial Blue<br />
LATEX AGGLUTINATION TESTS (LATS)<br />
In the classic LAT, beads are coated with antigen for the detection of<br />
antibody in serum or blood samples. If present, the antibody bridges<br />
antigen-coated microspheres, causing agglutination. Positive results<br />
are visually apparent as the homogeneous, milky white suspension<br />
takes on a grainy or sandy appearance. Undyed “white” spheres<br />
are often spotted on black cards, and dyed spheres may be applied<br />
to slides or white cards. See TN301, Immunological Applications.<br />
Catalog Code Description Bead Size (µm)<br />
PC02N - PC04N Carboxyl Polymer ≤ 0.49 - 1.99<br />
DC02N - DC04N Dyed Carboxyl Polymer ≤ 0.49 - 1.99<br />
LATERAL FLOW TESTS<br />
Dyed submicron microspheres are commonly<br />
used as the mobile phase in lateral<br />
flow tests. Vibrant colors permit visual<br />
detection of test results, and fluorescent<br />
versions such as europium chelate spheres<br />
may be used with specialized readers.<br />
See TN303, Lateral Flow Tests.<br />
Catalog Code Description Bead Size (µm)<br />
DC02* - DC04*<br />
Dyed Carboxyl<br />
Polymer<br />
≤ 0.49 - 1.99<br />
DS02* - DS04* Dyed Polymer ≤ 0.49 - 1.99<br />
bind initially)<br />
Detector<br />
Reagent<br />
Antibody against<br />
Target Analyte<br />
(Epitope 1)<br />
Capture<br />
(Test) Zone<br />
Control<br />
(Neg) Zone<br />
Y<br />
Capture<br />
Reagent<br />
Antibody against<br />
Target Analyte<br />
(Epitope 2)<br />
Y<br />
Species-specific<br />
anti-immunoglobulin<br />
against detector<br />
reagent<br />
Absorbent<br />
Pad<br />
Side View<br />
Typical immunochromatography test strip. (Image courtesy of<br />
Millipore Corporation.)<br />
Plastic<br />
Backing<br />
Conjugate Pad Absorbent Pad Adhesive<br />
Bangs Laboratories Microsphere Reagent Development<br />
3