The main extracting fan delivering the exhaust fumes from the mechanical<br />

pulverisation process maintains the airflow through the plant. This allows the<br />

purification plant to continuously operate in a slight negative pressure; thus<br />

avoiding fugitive leaks and emissions to the installation area.<br />

The full abatement plant is supervised and operated from a dedicated control<br />

panel. All switches, instruments, and lamp indicators are situated on the panel as<br />

well as a flow diagram on which the actual running mode is indicated.<br />

The system includes 5 separate stages to control peaks and eliminate various<br />

pollutants:<br />

• Dust filter<br />

• Adsorber<br />

• Catalytic Abator<br />

• Chemical scrubber<br />

• Neutralization of waste water<br />

1) Dust filter<br />

Pulse jet filter and cartridge filters are used to collect any duct particles and prevent<br />

foam from accessing the other parts of the abatement plant.<br />