The main extracting fan delivering the exhaust fumes from the mechanical<br />
pulverisation process maintains the airflow through the plant. This allows the<br />
purification plant to continuously operate in a slight negative pressure; thus<br />
avoiding fugitive leaks and emissions to the installation area.<br />
The full abatement plant is supervised and operated from a dedicated control<br />
panel. All switches, instruments, and lamp indicators are situated on the panel as<br />
well as a flow diagram on which the actual running mode is indicated.<br />
The system includes 5 separate stages to control peaks and eliminate various<br />
pollutants:<br />
• Dust filter<br />
• Adsorber<br />
• Catalytic Abator<br />
• Chemical scrubber<br />
• Neutralization of waste water<br />
1) Dust filter<br />
Pulse jet filter and cartridge filters are used to collect any duct particles and prevent<br />
foam from accessing the other parts of the abatement plant.<br />
3