26.01.2017 Views

IDEM Product CATALOG

IDEM Safety Switches Product Catalog - PCC US Distributor of IDEM

IDEM Safety Switches Product Catalog - PCC US Distributor of IDEM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SECTION 23<br />

www.idemsafety.com IDEBUS BUS SYSTEM - 2 WIRE SAFETY COMMUNICATION FOR ROPE SWITCHES<br />

2 Wire Safety Communication for Rope Switches - IdeSafe Bus System<br />

2 WIRE SAFETY SYSTEM FOR USE WITH ROPE SWITCHES COVERING LONG DISTANCES:<br />

The IdeSafe Bus System allows GLH switches to be connected in series to protect long conveyor lengths over 5km whilst maintaining diagnostics<br />

and safety integrity.<br />

Each switch contains an address programmable module to give individual diagnostics of the switch status and is readable at the control cabinet.<br />

Open circuits are detected.<br />

The whole system is connected in series by a simple 2-wire connection system from switch to switch making wiring simple and easy. Up to 63<br />

switches can be connected to one “Bus”.<br />

Safety integrity is maintained throughout via positively opened switch contacts connected to the transmission bus to maintain PLe to ISO13849-1 and<br />

SIL3 to EN62061.<br />

Communication capabilities - can be interfaced to most Text Displays, Touch Screens, PLCs and PCs via the gateways for Modbus and Profibus.<br />

High flexibility - it is easy to expand the system step-by-step by installing additional safety input modules.<br />

Basic elements required - Master Module, Safety Receiver and Rope Switches with Input Modules.<br />

DESCRIPTION:<br />

Bus powered address “modules” are integrally fitted within the Rope Switch housings and protected to IP67.<br />

They monitor the positively operated switch contacts to provide a 2-wire (channel) safety signal output which is monitored by the Safety Receiver<br />

Relay. The “Safe State” signal is transmitted continuously by each switch to the Safety Relay as long as the switch contacts are closed and the<br />

module self check is positive. Short circuit and open circuit faults are detected along the 2-wire continuous connection.<br />

SUITABLE APPLICATIONS:<br />

● Mines and Tunnelling ● Cement Manufacturing Plants ● Quarrying<br />

● Power Plants ● Harbours and Docksides ● Conveyors on Sorting Systems<br />

● Airport Systems ● Postal Systems ● Automated Logistic Systems<br />

● Cranes and Elevators ● Automatic Door Systems ● Petro-Chemical Plants<br />

Programmable 2-wire Safety Bus System<br />

Satisfies highest safety levels using a 2-wire connection bus<br />

DIN rail mounting<br />

Monitored or Auto Reset<br />

High flexibility - easy to expand the system<br />

Communication capabilities - can be interfaced to most Text Displays<br />

Profibus connection module available for diagnostic connection to PLC<br />

Master Module<br />

INPUT MODULE<br />

INPUT MODULE<br />

INPUT MODULE<br />

IdeSafe Bus<br />

Safety Receiver<br />

GS38300143230<br />

Multi Channel<br />

230V-50/60Hz<br />

Safety Relay Module<br />

IdeSafe Bus<br />

2-wire connection only.<br />

Input Modules are address programmable and are<br />

incorporated within the safety switches.<br />

The Safety Relay will open the contacts if it does not<br />

receive a valid “input contact closed” signal from all the<br />

input modules which it has been configured to monitor.<br />

Diagnostic information via PLC, PC or Text Display.<br />

Up to 63 safety signals (switches) on one IdeSafe Bus.<br />

PLe ISO13849-1 SIL3 EN61508 TUV Approved.<br />

Safety Receiver<br />

GS38300143230<br />

Multi Channel<br />

230V-50/60Hz<br />

Optional PROFIBUS<br />

INTERFACE allows for<br />

monitoring of the system<br />

e.g. using a PLC.<br />

216<br />

Input Modules are incorporated within safety switches

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!