21.02.2018 Views

Reverse Osmosis Membranes catalogue

We are a wholesale supplier of products, solutions and services in water treatment. We provide only businesses companies such as distributors, retailers, manufacturers and assemblers. A catalog that includes products carefully selected from the most prestigious brands in the Water Treatment market, operative site, personalized services, logistics precise and efficient, flexible organization, but also the basic importance that is attributed to human factors and relationships with partners, are of Sinergroup Srl a reference for many companies of the sector.

We are a wholesale supplier of products, solutions and services in water treatment.
We provide only businesses companies such as distributors, retailers, manufacturers and assemblers.

A catalog that includes products carefully selected from the most prestigious brands in the Water Treatment market, operative site, personalized services, logistics precise and efficient, flexible organization, but also the basic importance that is attributed to human factors and relationships with partners, are of Sinergroup Srl a reference for many companies of the sector.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX<br />

<strong>Membranes</strong> ............................................................................................................................................................. 3


<strong>Membranes</strong><br />

Code: 090001<br />

Filmtec membrane TFC TW30 1812 - 50, 75, 100 GPD (25)<br />

Variants<br />

Code<br />

Description<br />

090001-01 Filmtec membrane TFC TW30 1812 - 50 GPD (25)<br />

090001-02 Filmtec membrane TFC TW30 1812 - 75 GPD (25)<br />

090001-03 Filmtec membrane TFC TW30 1812 - 100 GPD (25)<br />

Code: 090005<br />

Greenfilter membrane TFC 1812/2012/3012/3013 - 50, 75, 100,<br />

150, 180, 300, 400 GPD<br />

Variants<br />

Code<br />

Description<br />

090005-50 Greenfilter membrane TFC 1812 - 50 GPD (25)<br />

090005-75 Greenfilter membrane TFC 1812 - 75 GPD (25)<br />

090005-100 Greenfilter membrane TFC 1812 - 100 GPD (25)<br />

090005-150 Greenfilter membrane TFC 1812 - 150 GPD (25)<br />

090005-180 Greenfilter membrane TFC 2012 - 180 GPD (25)<br />

090005-300 Greenfilter membrane TFC 3012 - 300 GPD (1)<br />

090005-400 Greenfilter membrane TFC 3013 - 400 GPD (1)<br />

Definition<br />

<strong>Reverse</strong> osmosis process is based on nature and has been used for more than 30 years. These semipermeable<br />

membranes only allow nearly pure water to flow through, by removing excessive salts during the<br />

process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.<br />

Type of membrane: Spiral wound<br />

Membrane consists of 3 layers<br />

1. Cross linked fully aromatic polyamide 0.3 µm.<br />

2. Polysulfone 45 µm .<br />

3. Non woven fabric polyester 100 µm.<br />

13 February 2018 3/19


Spacer: EPDM<br />

SPECIFICATIONS OF PRODUCT<br />

Membrane 50 GPD Cod. 090005-50<br />

Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

Membrane 75 GPD Cod. 090005-75<br />

Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

Membrane 100 GPD Cod. 090005-100<br />

Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

Membrane 150 GPD Cod. 090005-150<br />

Active surface: x,xxm²(xft²) * Pressure 3,5bar(50psi) * Production flow(N1) 23,66 l/h(150gpd) * Salts<br />

rejection(N2) 97,5% * Recovery del 15%<br />

Membrane 180 GPD Cod. 090005-180<br />

Active surface: x,xxm²(xft²) * Pressure 8bar(116psi) * Production flow(N1) 45,83 l/h(300gpd) * Salts<br />

rejection(N2) 93% * Recovery del 15%<br />

Membrane 300 GPD Cod. 090005-300<br />

Active surface: x,xxm²(xft²) * Pressure x,xbar(xxpsi) * Production flow(N1) xx,xx l/h(300gpd) * Salts<br />

rejection(N2) 95% * Recovery del 15%<br />

Membrane 400 GPD Cod. 090005-400<br />

Active surface: x,xxm²(xft²) * Pressure 4,5bar(65psi) * Production flow(N1) 1.512 l/d(400gpd) * Salts<br />

rejection(N2) 95% * Recovery del 15%<br />

(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF),<br />

15% recovery<br />

and specified applied pressure. Permeated flows for individual elements may vary +/- 15%.<br />

(N2) Minimum SALT rejection is 95%<br />

OPERATING LIMITS OF 50, 75, 100 GPD<br />

* Max. temperature 45ºC (113ºF)<br />

* Max. pressure 21 bar (300 psi)<br />

* Max. P for element 1 bar (15 psi)<br />

* Max feed flow rate 7,6 lpm (2.0 gpm)<br />

* pH range, continuous operation 3 - 10<br />

* pH range, short-term cleaning (30 min) 2 - 11<br />

* Max. Feed SDI 5<br />

* Free Chlorine tolerance¹


• All membranes are tested strictly and vacuum sealed in a bag containing a solution of sodium-bisulphite<br />

and propylene glycol to prevent biological growth in short-term storage and transport.<br />

• It is suggested that firs hour of pure water to be rejected.<br />

• Keep elements moist after initial wetting.<br />

• To prevent biological growth during prolonged system shutdown, it is recommended that membrane<br />

elements be immersed in a preservative solution.<br />

• The membrane shows some resistance to short-term attack by chlorine (hypochlorite). Continuous<br />

exposure, however, may damage the membrane and should be avoided.<br />

• The customer is fully responsible for effects of incompatible chemicals and lubricants on elements.<br />

• Use just glycerine as a lubricant if is needed.<br />

• The use of this product in and of itself does not necessarily guarantee the removal of cysts and<br />

pathogens from water. Effective cyst and pathogen reduction is dependent of the complete system design<br />

and on the operation and maintenance of the system.<br />

Code: 090018<br />

Greenfilter encapsulated membranes TFC 50, 75, 100 GPD<br />

Variants<br />

Code<br />

Description<br />

090018-01 Greenfilter encapsulated membrane TFC 50 GPD<br />

090018-02 Greenfilter encapsulated membrane TFC 75 GPD<br />

090018-03 Greenfilter encapsulated membrane TFC 75 GPD Filmtec<br />

090018-04 Greenfilter encapsulated membrane TFC 100 GPD<br />

High efficiency, disposable encapsulate membranes.<br />

Change complete of vessel + membrane for maximum hygiene!<br />

These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive<br />

salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus.<br />

Type of membrane: Spiral wound<br />

Membrane consists of 3 layers<br />

1. Cross linked fully aromatic polyamide 0.3 µm.<br />

2. Polysulfone 45 µm .<br />

3. Non woven fabric polyester 100 µm.<br />

Spacer: EPDM<br />

SPECIFICATIONS OF PRODUCT<br />

Membrane 50 GPD Cod. 090018-01<br />

Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 9,45l/h (60gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

Membrane 75 GPD Cod. 090018-02<br />

Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

Membrane 75 GPD Cod. 090018-03 Filmtec®<br />

13 February 2018 5/19


Active surface: 0,37m²(4ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 11,81l/h (75gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

Membrane 100 GPD Cod. 090018-04<br />

Active surface: 0,46m²(5ft²) * Pressure 4,5bar(65psi) * Production flow(N1) 15,75l/h (100gpd) * Salts<br />

rejection(N2) 97% * Recovery 15%<br />

(N1) Permeated flow and salt rejection based on the following test conditions: 500ppm NaCl, 25ºC (77ºF),<br />

15% recovery<br />

and specified applied pressure. Permeated flows for individual elements may vary +/- 15%.<br />

(N2) Minimum SALT rejection is 95%<br />

Connections:<br />

* Inlet water: O.D. stem Ø 3/8"<br />

* Outlet permeate: O.D. stem Ø 1/4"<br />

* Drain: O.D. stem Ø 1/4"<br />

OPERATING LIMITS OF 50, 75, 100 GPD<br />

* Max. temperature 45ºC (113ºF)<br />

* Max. pressure 21 bar (300 psi)<br />

* Max. P for element 1 bar (15 psi)<br />

* Max feed flow rate 7,6 lpm (2.0 gpm)<br />

* pH range, continuous operation 3 - 10<br />

* pH range, short-term cleaning (30 min) 2 - 11<br />

* Max. Feed SDI 5<br />

* Free Chlorine tolerance¹


Permeate flow rate (+/-20%) 50: 50 Gpd (190 lt./day)<br />

Permeate flow rate (+/-20%) 75: 75 Gpd (284 lt./day)<br />

Permeate flow rate (+/-20%) 100: 100 Gpd (379 lt./day)<br />

Permeate flow rate (+/-20%) 150: 150 Gpd (568 lt./day)<br />

Permeate flow rate (+/-20%) 180: 180 Gpd (681 lt./day)<br />

Minimum salt rejection: 96%<br />

Stabilized salt rejection: 98%<br />

Operating pressure test:<br />

65 PSI<br />

TDS feed test:<br />

Tap Water (from 450 to 700 ppm)<br />

Water temperature test:<br />

77°F. (25°C.)<br />

Recovery test: 15%<br />

Max. operating pressure:<br />

125 PSIG / 0.86 MPa (8,6 Bar)<br />

Max. feed SDI:<br />

5 (15 min)<br />

Max. feed flow rate:<br />

2 gal./min. (7,57 lt./min.)<br />

Chlorine tolerance:<br />


150 GPD 0.58 m2 (6.2 sq. ft)<br />

180 GPD 0.64 m2 (6.9 sq. ft)<br />

TFC Nominal Rejection Characteristics:<br />

Calcium: 93-98%<br />

Sodium: 92-98%<br />

Magnesium: 93-98%<br />

Potassium: 92-96%<br />

Manganese: 96-98%<br />

Iron: 96-98%<br />

Aluminum: 96-98%<br />

Copper: 96-98%<br />

Nickel: 96-98%<br />

Cadmium: 93-97%<br />

Silver: 93-96%<br />

Zinc: 96-98%<br />

Mercury: 94-97%<br />

Hardness Ca & Mg: 93-97%<br />

Radioactivity: 93-97%<br />

Chloride: 92-95%<br />

Ammonium: 80-90%<br />

Bromide: 90-95%<br />

Phosphate: 95-98%<br />

Chromate: 85-95%<br />

Cyanide: 85-95%<br />

Sulfate: 96-98%<br />

Thiosulfate: 96-98%<br />

Silicate: 92-95%<br />

Silica: 80-90%<br />

Nitrate: 90-95%<br />

Boron: 50-70%<br />

Borate: 30-50%<br />

Fluoride: 92-95%<br />

Polyphosphate: 96-98%<br />

Orthophosphate: 96-98%<br />

Chromate: 85-95%<br />

Virus and Bacteria: 99% +<br />

Lead: 95-98%<br />

The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the<br />

feed water.<br />

WARNING<br />

The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water)<br />

and it works only if it's installed on water complies with the law, municipal potable water or well water if<br />

previously made drinkable with adequate and effective systems, preventively studied and personalized for<br />

that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown<br />

quality without adequate disinfection before and after the system. All systems must be preserved according<br />

to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in<br />

your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.<br />

13 February 2018 8/19


Code: 090019<br />

Pentair GRO encapsulated membranes TLC 36, 50, 75 GPD (16)<br />

Variants<br />

Code<br />

Description<br />

090019-01 Pentair GRO-36EN GPD encapsulated membranes<br />

090019-02 Pentair GRO-50EN GPD encapsulated membranes<br />

090019-03 Pentair GRO-75EN GPD encapsulated membranes<br />

GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high<br />

quality reverse osmosis water while wasting 3 times less water to the drain.<br />

Features<br />

* TLC Thin Layer Composite membrane<br />

* 100% dry membrane maximizing shelf life<br />

* Double the recovery over standard RO elements<br />

* High rejection stability at high input TDS<br />

* Maximal Pressure: 6.90 bar<br />

* Maximal Temperature: 49°C<br />

* pH: 4-11<br />

* Free Chlorine: 0.1 ppm<br />

Connections:<br />

* Inlet water: 1/4" Quick Fit<br />

* Outlet permeate: 1/4" Quick Fit<br />

* Drain: 1/4" Quick Fit<br />

Benefits<br />

* 4 times less water rejected to the drain (1:1 with GRO and 1:4 with standard RO )<br />

* High performances even under extreme conditions<br />

* Membrane can be stored for a longer period of time<br />

Nominal performance GRO-36EN<br />

* Flow* Gpd (Lpd): 36 (136.3)<br />

* Rejection: 96%<br />

* Drain flow control (ml./min.): 100<br />

Nominal performance GRO-50EN<br />

* Flow* Gpd (Lpd): 50 (189.3)<br />

* Rejection: 96%<br />

* Drain flow control (ml./min.): 150<br />

Nominal performance GRO-75EN<br />

* Flow* Gpd (Lpd): 75 (283.9)<br />

* Rejection:96%<br />

* Drain flow control (ml./min.): 200<br />

13 February 2018 9/19


Note: The data above is based on internal laboratory testing.<br />

* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 50% recovery after<br />

24 hours. Individual element flux may vary ± 15%.<br />

The GRO-36EN, GRO-50EN and GRO-75EN are Tested and Certified by NSF International against<br />

NSF/ANSI Standard 58 for materials and structural integrity requirements.<br />

Here is the expected amount of water saved each year, for a family of 4 people:<br />

Yearly water consumption: 3 lt./day/person x 1 year = 4’380 lt.<br />

Standard RO membrane: 17’520 lt. of rejected water<br />

GRO membrane: 4’380 lt. of rejected water<br />

The use of GRO membranes allows a saving of about 13’000 lt. of water per year.<br />

Code: 090012<br />

Pentair membrane TLC 50, 75, 100 GPD (25)<br />

Variants<br />

Code<br />

Description<br />

090012-050 Pentair membrane TLC - 50GPD (25)<br />

090012-075 Pentair membrane TLC - 75GPD (25)<br />

090012-100 Pentair membrane TLC - 100GPD (25)<br />

TLC RESIDENTIAL RO MEMBRANES<br />

The best way to assess the overall filtration quality of a RO system is made by measuring the rejection,<br />

which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the<br />

rejection, the better the membrane performs. The recovery of a RO system represents the quantity of<br />

permeate produced compared with the quantity of concentrate rejected to the drain. The higher the<br />

recovery, the lower the rejection is.<br />

RO MEMBRANE’S CONSTRUCTION<br />

The spiral-wound membrane element is constructed of one or more membrane envelopes wounded around<br />

a perforated central tube. Purified water passes through the membrane and is collected in the permeate<br />

collection material while rejected impurities stay in the feed channel spacer.<br />

TLC RANGE<br />

TLC (Thin Layer Composite) range is made of 5 reverse osmosis membranes which will allow to cover any<br />

types of needs from the customer. Dimensions of these membranes are standard; they will fit into any<br />

reverse osmosis systems from the market.<br />

FEATURES<br />

• TLC Thin Layer Composite membrane<br />

• 100% dry membrane maximizing shelf life<br />

• High rejection stability at high input TDS<br />

• Standard dimensions: can be fitted in any RO systems<br />

• Maximal Pressure: 6.90 bar<br />

• Maximal Temperature: 49°C<br />

• pH: 4-11<br />

• Hardness: 17°F<br />

• Free Chlorine: 0.1 ppm<br />

13 February 2018 10/19


• Rejection*: 98%<br />

NOMINAL PERFORMANCE TLC-50<br />

• Flow* Gpd (Lpd): 50 (189.3)<br />

NOMINAL PERFORMANCE TLC-75<br />

• Flow* Gpd (Lpd): 75 (283.9)<br />

NOMINAL PERFORMANCE TLC-100<br />

• Flow* Gpd (Lpd): 100 (378.5)<br />

* Nominal performances are based on a 500 ppm softened tap water at 4.5 bar, 25ºC, 15% recovery after<br />

24 hours. Individual element flux may vary ± 15%.<br />

BENEFITS OF TLC MEMBRANES<br />

100% dry membranes: maximum shelf life. Each RO membrane is individually packed dry in a plastic bag.<br />

We’re not adding any chemical preservative, avoiding the risk of bacterial contamination, which can<br />

happen when the preservative is expired. If properly stored the shelf life of our RO membranes is almost<br />

endless!<br />

HIGH REJECTION STABILITY EVEN AT HIGH INPUT TDS<br />

Whatever the amount of total dissolved solids from the inlet water, TLC membranes will always give<br />

optimal performances. When compared with a membrane from competition, we can clearly see that<br />

Pentair’s TLC 75 will give better results: the rejection will remain stable between 96 and 98% even at<br />

1000ppm whereas it will be lower (89 to 92%) for the membrane from competition**.<br />

**Results obtained from internal testing (more testing results are available upon request)<br />

NSF CERTIFIED<br />

Our membranes are tested and certified by NSF International against NSF/ANSI Standard 58, which will<br />

save time and money during the NSF certification process of the complete RO system by the OEM.<br />

NSF COMPONENT<br />

The TLC-100 is Tested and Certified by NSF International against NSF/ANSI Standard 58 for material<br />

requirements only. The TLC-24, TLC-36, TLC-50, and TLC-75 are tested & certified by NSF/ANSI to<br />

standard 58 for the reduction of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent),<br />

Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium & TDS<br />

IMPORTANT INFORMATION<br />

Filters and membrane elements are not to be installed on microbiologically unsafe water supplies. TLC<br />

<strong>Membranes</strong> are not certified to sanitize water, remove cysts, bacteria, or viruses. Filter and membrane<br />

element performance can be affected by fluctuations in water quality.<br />

Code: 090007<br />

AMI membrane TFC 1812/3012 100, 150, 300 GPD (25)<br />

13 February 2018 11/19


Variants<br />

Code<br />

Description<br />

090007-100 AMI membrane TFC 1812 - 100GPD (25)<br />

090007-150 AMI membrane TFC 1812 - 150GPD (25)<br />

090007-300 AMI membrane TFC 3012 - 300GPD (25)<br />

AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of<br />

thousands of membranes in operation world-wide, we offer these in a large range of both residential and<br />

commercial sizes AMI <strong>Membranes</strong> are Made in the USA in our ISO 9001:2008 Certified Facilities. For the<br />

past 30 years AMI Membrane elements have earned the reputation of consistent quality.<br />

Recommended Operating Conditions (50, 75, 100, 150gpd)<br />

* Maximum operating pressure: 125 psi (8,61bar)<br />

* Maximum feed flow rate: 2 gpm (7,57lt./min.)<br />

* Maximum operating temperature: 113°F (45°C)<br />

* Maximum feed water turbidity: 1 NTU<br />

* Maximum feed water silt density index (15 min): 5<br />

* Chlorine tolerance:


Variants<br />

Code<br />

Description<br />

090008-150 AMI nanofiltration membrane NF 1812 - 150GPD (25)<br />

090008-200 AMI nanofiltration membrane NF 1812 - 200GPD (25)<br />

Nanofiltration Membrane Elements: NF5<br />

What is Nanofiltration?<br />

Nanofiltration (NF), in concept and operation, is much the same as reverse osmosis. The key difference is<br />

the degree of removal of monovalent ions such as chlorides. <strong>Reverse</strong> osmosis removes the monovalent<br />

ions at 98-99% level at 200psi (13,78bar). Nanofiltration membranes’ removal of monovalent ions varies<br />

between 50% to 90% depending on the material and manufacture of the membrane. For this reason, there<br />

is a variety of<br />

Nanofiltration membranes available. Each type is particularly suited to a certain application and may not be<br />

acceptable to a different application.<br />

Nanofiltration membranes (NF membranes) and systems are used for water softening, food and<br />

pharmaceutical applications.<br />

Recommended Operating Conditions<br />

* Maximum operating pressure: 300psi (20,68bar)<br />

* Maximum operating temperature: 113°F (45°C)<br />

* Maximum feed water turbidity: 1 NTU<br />

* Maximum feed water silt density index (15 min): 4<br />

* Chlorine tolerance:


Test condition<br />

Applied pressure: 150PSI(10,34BAR) * Feed water temperature: 25°C * NaCl Concentration: 500ppm *<br />

Recovery: 15%<br />

Operating limits<br />

Max. temperature 40ºC * Recovery range 10-20% * Maximum operating pressure 21bar(300 psi) *<br />

Operating PH range: 4-11 * Chlorine tolerance


Code: 090011<br />

Housings for reverse osmosis membrane 3012 - 300GPD<br />

Greenfilter (1)<br />

Connections<br />

* Inlet: 1/8" * Outlet/Drain: 1/8"<br />

Code: 090021<br />

Vessel for reverse osmosis membrane 3012 - 300GPD<br />

Connections<br />

* Inlet: 1/4" * Outlet/Drain: 1/8"<br />

Code: 090014<br />

Yarn Home membrane TFC 3013 - 400 GPD (1)<br />

13 February 2018 15/19


Code: 090015<br />

Vessel for reverse osmosis membrane 3013 - 400GPD quick<br />

fittings connections clips<br />

Connections<br />

* Inlet: 3/8" * Outlet/Drain: 1/4"<br />

Code: 090016<br />

Vessel for reverse osmosis membrane 3013 - 400GPD<br />

Connections<br />

* Inlet: 1/4" * Outlet/Drain: 1/8"<br />

Code: 090022<br />

Vessel for reverse osmosis membrane 3013 - 400GPD<br />

Connections<br />

* Inlet: 1/4" * Outlet/Drain: 1/8"<br />

13 February 2018 16/19


Code: 090013<br />

Greenfilter membrane TFC LP2514, LP2521, LP2540, LP4040<br />

Medium pressure<br />

Variants<br />

Code<br />

Description<br />

090013-01 Greenfilter membrane TFC LP2521 Medium pressure<br />

090013-02 Greenfilter membrane TFC LP2540 Medium pressure<br />

090013-03 Greenfilter membrane TFC LP4040 Medium pressure<br />

090013-04 Greenfilter membrane TFC LP2514 Medium pressure<br />

Code: 090020<br />

Housings 4" for reverse osmosis membrane 4040x1 - 300psi-<br />

EP Greenfilter<br />

Variants<br />

Code<br />

Description<br />

090020-02 Housings 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter<br />

Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02<br />

Features:<br />

* Made of fiber reinforced polyester.<br />

* Front connection, permeate the collection at both ends.<br />

* Close by blocking half-length AISI-304 easy membrane replacement.<br />

* EPDM seals. ABS collector plugs.<br />

* Compatible with standard 4 "membranes.<br />

* Support brackets included.<br />

Connections:<br />

* Inlet: 1/2" BSP F.<br />

* Outlet/Drain: 3/4" BSP F<br />

Technical features:<br />

* Pressure: 21 kg/cm2, 21 bar (300 psi)<br />

* Permeate internal pressure: < 8,8kg/cm2, 7bar (125 psi)<br />

* Max. temperature: 49°C (120.2°F)<br />

13 February 2018 17/19


* Min. temperature: -10°C (14°F)<br />

* pH range, continuous operation: 3-11<br />

* pH range, short-term cleaning: 2-12 (max 30 min.)<br />

* Weight: 6 kg<br />