Modulating Float Control Valve E5100-10
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
MODULATING FLOAT<br />
CONTROL VALVE, <strong>E5<strong>10</strong>0</strong>-<strong>10</strong><br />
Envotec <strong>E5<strong>10</strong>0</strong>-<strong>10</strong> Pilot Operated <strong>Modulating</strong> <strong>Float</strong> <strong>Control</strong><br />
<strong>Valve</strong> designed to maintain water level in a reservoir or tank.<br />
Buoyancy of float pilot assembly throttles main valve to open<br />
on a lowering water level and throttles to close upon a rising<br />
water level. The valve proportionately begins to close upon a<br />
rising water level and drip-tight at the maximum level reached.<br />
The float pilot assembly is remotely (inside water tank) installed<br />
where the main valve installed externally is inter-connected with<br />
a sensing tube field installed to operate main valve.<br />
TECHNICAL SPECIFICATIONS<br />
Max. Working Pressure: 16 bar (232 psi)<br />
Max. Working Temperature: 80ºC (176°F)<br />
Nominal Diameter: DN32~ DN600<br />
Fluid Medium: Water<br />
APPLICATIONS<br />
• Water supply, distribution & pump stations.<br />
• Water treatment.<br />
• Water supply stations (airports, marine and fluvial ports).<br />
• Sports complexes, Swimming pools, Aquariums,<br />
Amusement parks.<br />
• Suitable for Residential, Commercial, Industrial, Irrigation,<br />
Fire protection & similar installations.<br />
FEATURES<br />
• High hydrodynamic section globe body, without<br />
stagnation pockets.<br />
• NSF Approved epoxy coating internal/external suits<br />
potable(drinking) water applications.<br />
• Simple structure, easy installation/disassembly.<br />
• Head loss and cavitation risks reduction.<br />
• Excellent corrosion strength.<br />
• Conformity with both European and American standards.<br />
• <strong>Valve</strong> equipped with pilot strainer to protect foreign debris<br />
entering to the pilot system.<br />
• <strong>Valve</strong> equipped with isolation cocks for easy maintenance.<br />
• Maintenance and repairs is possible without removing the<br />
main valve body from the line.<br />
• <strong>Valve</strong> equipped with pressure gauge for physical visualization<br />
of inlet/outlet pressure.<br />
• Main-valve body provisioned with drain plug for flushing out<br />
dirt during the preliminary installation and when required.<br />
• <strong>Valve</strong> equipped with position indicator for physical<br />
visualization of valve open/close position.<br />
SCHEMATIC DESIGN<br />
1. <strong>Valve</strong> Body<br />
2. <strong>Valve</strong> Cover<br />
3. <strong>Float</strong> Pilot Assembly<br />
4. <strong>Control</strong> Circuit “Y” Strainer<br />
5. <strong>Control</strong> Circuit Isolation <strong>Valve</strong>s<br />
6. Position Indicator<br />
7. Flow Restrictor<br />
8. Body Drain Plug<br />
Envotec INC | 306 Avenida Salvador | San Clemente | CA92672 | USA<br />
Ph: +1 (949) 332-0880 | Fax: +1 (770) 234-6664<br />
E-mail: info@envotec.us | Web: www.envotec.us PAGE 1 OF 4
MAIN VALVE, E5000 FLOAT PILOT, E51-<strong>10</strong><br />
Body & Cover: Ductile Iron ASTM A536<br />
Coating: Fusion Bonded Epoxy Coating to 300 Microns<br />
Seat/Stem/Spring: Stainless Steel 316<br />
Diaphragm/Disc/O-ring: EPDM<br />
Diaphragm Washer: Stainless Steel 316<br />
Disc Retainer/Guide: Stainless Steel 316<br />
Cover Bearing: Stainless Steel 316<br />
Cover Bolts/Seat Screws: Stainless Steel 316<br />
Body/Cover Plugs: Stainless Steel 316<br />
STANDARD PILOT SYSTEM<br />
Ball <strong>Valve</strong> (Isolation Cocks): Brass , EBV-BR<strong>10</strong>0<br />
Y-Strainer: Bronze ASTM B62, ES-BZ<strong>10</strong>0<br />
Position Indicator: SS316, EPI-<strong>10</strong>0<br />
Body: Bronze ASTM B62<br />
Stem: Brass Heavy Duty<br />
<strong>Float</strong>: Copper Brazed, Plastic (Optional)<br />
Adjustable Arm: Bronze ASTM B62<br />
SENSING TUBE<br />
Material: Nylon Heavy Duty & High Temperature Resistance<br />
Length: 5mtr<br />
PILOT CIRCUIT<br />
Tubing: Copper<br />
Tube Fittings: Brass<br />
OTHER CONFIGURATIONS<br />
<strong>E5<strong>10</strong>0</strong>-11 On/Off <strong>Float</strong> <strong>Control</strong> <strong>Valve</strong> (Mechanical Delayed Action)<br />
<strong>E5<strong>10</strong>0</strong>-12 <strong>Modulating</strong> with Pressure Sustaining <strong>Control</strong> <strong>Valve</strong><br />
<strong>E5<strong>10</strong>0</strong>-13 On-Off with Pressure Sustaining <strong>Control</strong> <strong>Valve</strong><br />
<strong>E5<strong>10</strong>0</strong>-14 <strong>Modulating</strong> with Solenoid (On-Off) <strong>Control</strong> <strong>Valve</strong><br />
WEIGHT & DIMENSIONS<br />
ØD L H B<br />
WEIGHT<br />
(Kgs)<br />
32 180 220 165 17<br />
40 180 220 165 17<br />
50 230 220 165 17<br />
65 290 230 185 20<br />
80 3<strong>10</strong> 290 200 26<br />
<strong>10</strong>0 350 3<strong>10</strong> 235 35<br />
125 400 340 270 48<br />
150 480 440 300 85<br />
200 600 535 360 115<br />
250 730 560 425 140<br />
300 850 660 485 420<br />
350 980 695 555 530<br />
400 1<strong>10</strong>0 985 620 800<br />
500 1250 <strong>10</strong>40 730 950<br />
600 1450 <strong>10</strong>95 845 1350<br />
700 1650 1305 9<strong>10</strong> 2600<br />
800 1850 1360 <strong>10</strong>25 3000<br />
All dimensions in: mm<br />
Envotec INC | 306 Avenida Salvador | San Clemente | CA92672 | USA<br />
Ph: +1 (949) 332-0880 | Fax: +1 (770) 234-6664<br />
E-mail: info@envotec.us | Web: www.envotec.us PAGE 2 OF 4
CAVITATION CURVE<br />
Too high pressure loss and too low downstream<br />
pressure may cause valve deterioration. To determine if<br />
cavitation is due to pressure conditions, it is necessary<br />
to refer to cavitation curve. Just in case reduce ∆p by<br />
installing more cascade flow control valves will help<br />
valve to work outside cavitation zone.<br />
A. Cavitation free zone<br />
B. Cavitation zone<br />
Kv FACTOR<br />
Kv factor values expressed in m3/h are intended for fully open valve and refer to flow rate which passing through the valve, causes<br />
a pressure loss equal to 1 bar.<br />
DN 50 65 80 <strong>10</strong>0 125 150 200 250 300 350 400 500 600 700 800<br />
Kv(m3/h) 50 52 1<strong>10</strong> 136 198 288 490 7<strong>10</strong> 1390 1530 2280 3220 3920 7200 7400<br />
Envotec INC | 306 Avenida Salvador | San Clemente | CA92672 | USA<br />
Ph: +1 (949) 332-0880 | Fax: +1 (770) 234-6664<br />
E-mail: info@envotec.us | Web: www.envotec.us PAGE 3 OF 4
INSTALLATION REQUIREMENTS<br />
Recommended to install valves in horizontal position.<br />
Avoid installing valves 6" and above in a vertical discharge position.<br />
If your installation requires vertical position, Consult factory or specify<br />
at the time of order.<br />
MAINTENANCE REQUIREMENTS<br />
An Isolation valve (Gate valve/Butterfly valve/Ball valve) should be installed before the automatic float<br />
control valve for easy maintenance without draining the piping system.<br />
INSTALLATION<br />
TYPICAL MODULATING FLOAT CONTROL VALVE -1<br />
TYPICAL MODULATING FLOAT CONTROL VALVE -2<br />
Note: It is recommended to install by a experienced/ trained product installer. You are required to thoroughly read<br />
all installation instructions and product safety information before beginning the installation of this product. Local<br />
plumbing codes shall govern installation requirements. Ensure that all applicable national, local building codes and<br />
safety rules are observed throughout the installation.<br />
All information contained herein design, construction, specifications, or materials was current at the time of printing. Because of Envotec policy of<br />
ongoing research and development, the Company reserves the right to discontinue or update product information such changes and modifications<br />
on Envotec products previously or subsequently sold without prior notice.<br />
Envotec INC | 306 Avenida Salvador | San Clemente | CA92672 | USA<br />
Ph: +1 (949) 332-0880 | Fax: +1 (770) 234-6664<br />
E-mail: info@envotec.us | Web: www.envotec.us PAGE 4 OF 4