The pressure loss through the coolant side of the plate heat exchanger shall be ≤ 100kPa<br />
at the nominal flowrate and 25°C coolant temperature<br />
The coolant is expected to be 50/50 ethylene glycol/water<br />
Heating<br />
• The heating elements shall be operated directly off battery system voltage, which varies<br />
between 560VDC and 740VDC<br />
o It is preferred that the heating elements be PTC-based<br />
• The <strong>HVAC</strong> unit shall have ≥ 16kW of total heating capacity at 650VDC (for conditioning cabin air<br />
only)<br />
Low Voltage<br />
• The low voltage system (fans, valves, controller, etc.) shall operate at 24VDC<br />
o The typical voltage range is 26.5VDC to 28VDC<br />
o The minimum voltage the at which the system shall be expected to operate is 20VDC<br />
• The low voltage system shall consume ≤ 3kW of power from the low voltage system<br />
Controls<br />
• The controls system shall support SAE J1939 protocol for control, feedback, and diagnostics<br />
Electrical<br />
• The isolation resistance between high voltage and ground shall be ≥ 10MΩ across all operating<br />
conditions<br />
• The isolation resistance between high voltage and low voltage shall be ≥ 10MΩ across all<br />
operating conditions<br />
• The total system x-capacitance across the high voltage input is expected to be ≤ 0.2mF<br />
Other Targets<br />
• Cost Target ≤US $20000.00<br />
• Weight Target ≤700 lbs.<br />
• Length ≤ 95 inches, Width ≤ 72 inches, Height ≤ 18 inches<br />
Target segments: The requirement is applicable to all <strong>Proterra</strong> vehicle platforms (35ft, 40ft, 60ft). If the<br />
solution is optimized as specified, it is possible that this unit would be the lead <strong>HVAC</strong> candidate for all<br />
future vehicle programs.<br />
Business Case: The design and development of the unit should be focused on optimizing cost and mass<br />
while meeting <strong>Proterra</strong>’s performance requirements. <strong>Spheros</strong> to provide development cost, piece price,<br />
and scope of development with milestone plan identified. Additionally, <strong>Spheros</strong> to describe standard<br />
offered warranty, service support strategy and geographic presence in North America.