TEMPERATURE AND HUMIDITY<br />

DATALOGGER WITH USB INTERFACE<br />

DEM105<br />

relative humidity: 0 - 100 % RH<br />

accuracy (0 % - 30 % and 70 % - 100 %): ± 5.0 % RH<br />

accuracy (30 % - 70 % ): ± 3.0 RH<br />

temperature: -40 °C tot 70 °C (-40 °F tot 158 °F)<br />

accuracy: (0 °C to 70 °C / 32 °F to 158 °F) ± 1 °C<br />

accuracy: (-40 °C to 0 °C/ -40 °F to 32 °F) ± 1.5 °C<br />

logging rate: selectable sampling interval: from<br />

1 second to 24 hours, operating temperature -35 °C<br />

to 80 °C (-31 °F to 176 °F) • power supply: 1 x lithium<br />

3.6 V / 1200 mAh SAFT 1/2AA (incl.) • memory for<br />

32700 readings • free selectable measurement<br />

cycle from 1 sec to 24 hours • display all Alarm and<br />

Record statuses with 2 LEDs • alarm will output<br />

a high pulse per 10 milliseconds if it exceeds the<br />

set high/low alarm value • analysis software used<br />

to view graphically or Text mode for logging data<br />

• USB computer interface (advanced software<br />

program for all windows) including W10<br />

(!4BA32J-fjjbac!<br />

TEMPERATURE AND HUMIDITY<br />

DATALOGGER WITH USB INTERFACE<br />

DEM171<br />

relative humidity: 0.1 tot 99.9% RH<br />

resolution: 0.1 RH • accuracy: ± 3% (at 25°C, 10-90%),<br />

other ± 5% • measured by: capacitor<br />

temperature: -30 °C tot 70 °C (-22 °F tot 158 °F)<br />

resolution: 0.1°C / 0.1°F •• accuracy: ± 0.5°C ••<br />

measured by: NTC thermistor • sampling points:<br />

24000 temperature and 24000 humidity • settings:<br />

sampling interval: 30 s, 5, 10, 30, 60, 90, 120 min ••<br />

start delay: 0, 5, 30, 45, 60, 90, 120 min and 24 h ••<br />

alarm range: from -30°C to 70°C / -22°F to 158°F<br />

•• alarm delay: 0, 5, 30, 45, 60, 90, 120 min •• alarm<br />

type: single event, cumulative, disable •• operation<br />

keys: start/stop, mark key, count key • batteries: 2 x<br />

CR2032C: LITHIUM 2032 3.0 V 230 mAh (incl.) • plug<br />

& play • Windows® • automatically generates a pdf<br />

and Excel report while plugged into computer •<br />

with USB 2.0 connector • completely programmable<br />

by the user for maximum flexibility : 6 languages,<br />

sampling interval, start delay, alarm delay, unit,<br />

alarm range, alarm type, password and user name •<br />

count key to review max. and min. values of logged<br />

data • REC, low battery, high/low temperature • PDF<br />

file with: summary, graphics and detailed data list<br />

(!4BA32J-ggicbb!


THERMO- & HYGROMETERS<br />

temperature<br />

range<br />

humidity<br />

range<br />

auto.<br />

OFF<br />

battery<br />

(incl.)<br />

extra<br />

DEM106<br />

DEM500<br />

K-type: -200° to 1370° C<br />

(-328° to 2498° F)<br />

J-type: -200° to 1100° C<br />

(-328° to 2012° F)<br />

-20°C to 70°C<br />

(-4°F to 158°F)<br />

- <br />

0 - 100% RH 15 min<br />

1 x 9 V<br />

6F22<br />

1 x 9 V<br />

6F22<br />

dual input measurement: for use with an<br />

external K-type or J-type thermocouple •<br />

dual measurement and dual display •<br />

max/min record • display hold<br />

max/min record<br />

(!4BA32J-fjhdca!<br />

(!4BA32J-fjhdca!<br />

DEM501<br />

-20°C tot 70°C<br />

(-4°F tot 158°F)<br />

0 - 100% RH 15 min<br />

1 x 9 V<br />

6F22<br />

max/min record • display hold • dew point<br />

temperature measurement<br />

(!4BA32J-fjjagf!<br />

DEM800 - 5 - 90% RH <br />

1 x 9 V<br />

6F22<br />

sawn timber, cardboard, paper, plaster,<br />

concrete and mortar • display hold<br />

(!4BA32J-fjjbhb!<br />

DEM801<br />

-20 tot +70°C<br />

(-4 tot +158°F)<br />

hout 1 - 70% RH<br />

building materials 30 sec.<br />

0.1 - 2.4% RH<br />

1 x 9 V<br />

6F22<br />

wood, wall board, cardboard, drywall,<br />

plaster, concrete and mortar • display hold<br />

(!4BA32J-gheaef!


IR-THERMOMETERS<br />

DEM104<br />

measurement<br />

range<br />

-50° C tot 260° C<br />

(-58° F ~ 500° F)<br />

measurement range<br />

K-type probe<br />

auto.<br />

OFF<br />

- 15 sec<br />

battery<br />

(incl.)<br />

2 x 1.5 V<br />

LR44<br />

data hold function<br />

(!4BA32J-fjjach!<br />

DEM100<br />

-50° C tot 330° C<br />

(-58° F ~ 626° F)<br />

- 20 sec<br />

1 x 9 V<br />

6F22<br />

data hold function<br />

(!4BA32J-fjhdee!<br />

DEM102<br />

-50° C tot 500° C<br />

(-58° F ~ 932° F)<br />

-50° C tot 1370° C<br />

(-58° F ~ 2498° F)<br />

10 sec<br />

1 x 9 V<br />

6F22<br />

MAX, MIN, DIF, AVG record<br />

REC datalogger for 12 points<br />

continuous scan function<br />

(!4BA32J-fjjaeb!<br />

Warning! Visible laser radiation. Do not stare into the beam as eye damage may occur. This device contains a class 2 laser.<br />

Output power does not exceed 1 mW, wavelength 650 nm.


LUX & ANEMOMETERS<br />

measurement<br />

range<br />

measurement<br />

range<br />

auto.<br />

OFF<br />

DEM300 0 - 200000 lux 15 min<br />

DEM301<br />

DEM400<br />

DEM401<br />

400, 4000,<br />

40000,<br />

400000 lux<br />

-30°C - +60°C<br />

(-22°F - +140°F)<br />

-30°C - +60°C<br />

(-22°F - 140°F)<br />

0.3-45 m/s • 0.5~87.5 knots • 0.6 -<br />

100.6 mph • 59-8858 ft/min • 1.0-<br />

162 km/h<br />

0.3-45 m/s • 0.5 ~ 87.5 knots •<br />

0.6 - 100.6 MPH • 59-8858 ft/min •<br />

1.0-162 km/h<br />

15 min<br />

15 min<br />

15 min<br />

battery<br />

(incl.)<br />

1 x 9 V<br />

6F22<br />

1 x 9 V<br />

6F22<br />

1 x 9 V<br />

6F22<br />

1 x 9 V<br />

6F22<br />

extra<br />

(!4BA32J-fjhdca!<br />

(!4BA32J-fjjahc!<br />

(!4BA32J-fjhdag!<br />

- (!4BA32J-fjjajg!<br />

max / min function<br />

max / min function<br />

• analog bar-graph<br />

indication<br />

data hold function


5 IN 1 MULTIFUNCTION ENVIRONMENT METER<br />

DEM900<br />

sound level: 35 - 130 dB<br />

measurement range: 35 dB ~ 130 dB • accuracy: ± 2.0 dB • resolution: 0.1 dB •<br />

frequency response: 31.5 Hz - 8 kHz • frequency weighting: dBA<br />

light: 0 lux - 200 K lux, 0 Fc - 20 KFc<br />

accuracy: ± 4 % rdg ± 0.5 % f.s. (


DISTANCE AND<br />

DECIBEL METERS<br />

DEM200<br />

measurement<br />

range<br />

30 - 130 dB<br />

frequency<br />

range<br />

31.5 Hz<br />

tot 8 kHz<br />

battery<br />

(incl.)<br />

1 x 9 V<br />

6F22<br />

extra<br />

(!4BA32J-fjhdbd!<br />

DEM201<br />

Auto:<br />

30 - 130 dB<br />

31.5 Hz<br />

tot 8 kHz<br />

1 x 9 V<br />

6F22<br />

(!4BA32J-fjjaij!<br />

DEM202<br />

30 - 130 dB<br />

31.5 Hz<br />

tot 8 kHz<br />

1 x 9 V 6F22 or<br />

optional power<br />

supply<br />

USB computer interface • PC real-time<br />

monitoring and recording • data logger function •<br />

memory up to 262.144 readings<br />

(!4BA32J-fjjbdd!<br />

DEM700<br />

DEM701<br />

0.05-60 m<br />

(0.16 - 196.8 ft)<br />

0.05-30 m<br />

(0.16 - 98.4 ft)<br />

2 x 1.5 V AA<br />

LR06C<br />

2 x 1.5 V AAA<br />

LR03C<br />

calculate distance, area and volume • single<br />

and continuous measurement • indirect<br />

measurements using 2 or 3 measuring points •<br />

last 10 measurements are retained in memory<br />

calculate distance, area and volume • with<br />

continuous measurement function • with<br />

Pythagorean proposition measurement function<br />

(!4BA32J-fjjbfh!<br />

(!4BA32J-gfafdh!<br />

*Note: Our sonometers are for indicative measurements only. They are not compliant with IEC 61672-1 electro-acoustic international standard so they<br />

cannot be used for official measurements.


V<br />

FOL/DEM20EN<br />

Velleman nv • Legen Heirweg 33 • 9890 Gavere • Belgium<br />

Responsible editor: Velleman nv • Do not throw on the public highway.<br />

+32 (0)9 384 36 11 info@velleman.eu<br />

velleman.eu

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!