You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Start-up guide of LSLV-M100
Basic set-up procedure
Motor direction inspection
• In this step the motor is checked for proper direction
and operation. This test is to be performed solely from
the Keypad. Apply power to the drive after all the
electrical connections have been made and protective
covers have been reattached.
Operation
Start/Stop and speed source settings
• This step shows how to setup the sequence and
reference method of the drive. The sequence method
determines how the drive receives its start and stop
command and the reference method determines how
the speed of the motor is controlled. Make sure all
protective covers have been reattached and power is
turned on.
• Select start / Stop method
ENT
Operation
ENT
ENT
MODE
SHIFT
Operation
0 Keypad Factory default
1 Fx/Rx-1
2 Fx/Rx-2
3 RS-485 communication Advanced I/O
ENT
MODE
SHIFT
MODE
SHIFT
MODE
SHIFT
RUN
RUN
STOP
RESET
STOP
RESET
24 P1 P2 P3 CM
0: Keypad Fx Rx
MODE
SHIFT
MODE
SHIFT
ENT
ENT
ENT
ENT
Operation
RUN
1: Fx/Rx-1
2: Fx/Rx-2
Please refer to user’s manual
• Observe the motor’s rotation from the load side and
ensure that the motor rotates counterclockwise
(forward).
• If the motor rotation is not correct, change the
wiring of the motor. (ex. U-V-W > V-U-W)
• Select frequency method
Operation
0 Keypad 1 Factory default
1 Keypad 2
2 V0: 0–5 [V] Built-in volume
3 V1: 0–10 [V] External source
4 I2( I ): 0–20 [mA]
5 I2(V): 0–10 [V]
Advanced I/O
6 V0 + I2 ( I )
7 V0 + I2 (V)
8 V0 + V1
9 RS-485 communication Advanced I/O
10 Up-down operation
24 P1 P2 P3 CM 24 P1 P2 P3 CM
EG Q1
VR V1 A0 CM
EG Q1
VR V1 A0 CM
2: VO, 0-5[V]
+
0 ~ 10 Vdc Potentiometer: 1-5K
3: V1, 0-10[V]
04 | LSIS Co., Ltd.