Diamond Systems LLC is a Veteran Administration verified VOSB and HUBZONE Certified Company providing field and fixed laboratory and portable products, safety equipment, for clinical, research, environmental, and hazardous applications. Our customers and focus includes IVF labs, food, brewery, pharmaceutical sciences, air and water quality researchers, landfill-bio digester applications and safety equipment for toxic gas, national security and personal protection. Over 30 years of experience with environmental applications and 100 years of collective manufacturing, representing manufacturers with USA based operations, offering ISO 9001, UL and safety related certifications for their products and solutions.

Diamond Systems LLC is a Veteran Administration verified VOSB and HUBZONE Certified Company providing field and fixed laboratory and portable products, safety equipment, for clinical, research, environmental, and hazardous applications. Our customers and focus includes IVF labs, food, brewery, pharmaceutical sciences, air and water quality researchers, landfill-bio digester applications and safety equipment for toxic gas, national security and personal protection. Over 30 years of experience with environmental applications and 100 years of collective manufacturing, representing manufacturers with USA based operations, offering ISO 9001, UL and safety related certifications for their products and solutions.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OMG100N1.16

G100 Range

12.0 Event Log

The following events are recorded in the instrument’s event log. The event log can only be

downloaded using the additional Analyzer Data Manager software. Please refer to the

Analyzer Data Manager software manual for further details.

Event

Cold Start/Reset

Firmware Version

Set time

Set date

Re-flash requested

Restore to factory settings

Comms clear memory

Change contrast

Change flow fail current limit

Battery less than critical voltage

RTC date/time invalid

Factory calibration invalid or overdue

Service invalid or overdue

Power on self-test, sensor out of range

User calibration set zero OK

User calibration set span OK

User calibration set zero failed

User calibration set span failed

Attempt to store when readings memory full

Readings memory nearly full

Change logging mode

Change logging mode ID

Flow fail current limit exceeded

Data

Type of start (MCUSR, boot_key)

Description

Before and After

Before and After

None

Type

Type 0=Readings, 1=Event Log

Before and After

Before and After

Critical, Actual

None

Date, difference

Date, difference

Channel, reading, limit

Before, After

Target, Before, After

Target, Reading

Target, Reading

Max

Limit, Actual

Status, Interval, Pump time

ID

Limit, Actual

VIASENSOR Page 48